GB/T 6730.82-2020 is the English-translated version of 铁矿石 钡含量的测定 EDTA滴定法.
GB/T 6730.82-2020 is the Chinese standard "Iron ores - Determination of barium content - EDTA titrimetric method". Its scope clause reads: This part of GB/T 6730 specifies the EDTA titration method for the determination of barium in iron ore.
This section applies to natural iron ore, iron concentrate and lump ore, including the determination of barium content in sintered products. Measuring range (mass fraction). 2.00%~20.00%. Its clauses include principle; reagent.
Found what you need?
Document preview — GB/T 6730.82-2020
National Standard of the People's Republic of China
- ICS
- 73.060.10
- Classification
- D 31
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Principle
- 4 Reagent
1 Scope
This part of GB/T 6730 specifies the EDTA titration method for the determination of barium in iron ore.
This section applies to natural iron ore, iron concentrate and lump ore, including the determination of barium content in sintered products. Measuring range (mass fraction).
2.00%~20.00%.
2 Normative references
The following documents are essential for the application of this document. For dated reference documents, only the dated version applies to this article
Pieces. For the cited documents without date, the latest version (including all amendments) applies to this document.
GB/T 6379.1 Accuracy of measurement methods and results (correctness and precision) Part 1.General rules and definitions
GB/T 6379.2 Accuracy of measurement methods and results (correctness and precision) Part 2.Determine the weight of standard measurement methods
The basic method of renaturation and reproducibility
GB/T 6682 Analysis of laboratory water specifications and test methods
GB/T 6730.1 Preparation of pre-dried samples for iron ore analysis
GB/T 8170 Numerical Rounding Rules and Representation and Judgment of Limit Values
GB/T 10322.1 Iron ore sampling and sample preparation methods
GB/T 12806 Laboratory glass instrument single mark volumetric flask
GB/T 12807 Laboratory glass instrument graduation pipette
GB/T 12808 Laboratory glass instrument single mark pipette
3 Principle
The sample is dissolved in hydrochloric acid, hydrofluoric acid, nitric acid, sulfuric acid is boiled and smoke dissolves barium sulfate, so that it forms barium bisulfate, diluted with water to precipitate pure
Barium sulfate is precipitated, filtered and washed to separate the barium from most interfering elements.
In an ammoniacal medium, heat the barium sulfate precipitate with an excess of EDTA standard solution to dissolve it, and titrate with magnesium chloride standard solution
EDTA standard solution, calculate the barium content in the sample.
If the strontium content in the sample is greater than 0.02%, add excess magnesium chloride-potassium dichromate standard solution to generate barium chromate and release EDTA Complex with excess magnesium ion, use KB as indicator, titrate with EDTA standard solution, calculate the barium content in the sample.
4 Reagent
Unless otherwise specified in the analysis, only approved analytically pure reagents and tertiary water in accordance with GB/T 6682 are used or their purity is equivalent
Water.
4.1
KB indicator, weigh 0.25g acidic complex blue K, 0.1g naphthol green B, 10g potassium chloride, grind and mix well.
4.2
Hydrochloric acid, rho about 1.19g/mL.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 6730.82-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6730.83-2022 — Iron ores - Determination of loss on ignition - Gravimetric method corrected by hygroscopic water
GB/T 6730.81-2020 — Iron ores—Determination of multiple trace elements—Inductively coupled plasma mass spectrometric method
GB/T 6730.84-2023 — Iron ores - Determination of total rare earth content - Inductively coupled plasma atomic emission spectrometry
GB/T 6730.82-2020
$210.00