GB/T 5054.3-2024Road vehicles - Multi-core connecting cables - Part 3: Construction, dimensions and marking of unscreened sheathed low-voltage cables (English PDF)
Also coversGBT5054.3-2024
This is a limited preview
Buy now to download the full PDF (14 pages)
Need quotation for your management?
Get a formal quotation for GB/T 5054.3-2024 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Recommended
Issue date
October 26, 2024
Implementation date
May 1, 2025
Scope
GB/T 5054.3-2024 (Road vehicles - Multi-core connecting cables - Part 3: Construction, dimensions and marking of unscreened sheathed low-voltage cables) is available as an English-translated PDF.
GB/T 5054.3-2024 is the Chinese standard "Road vehicles - Multi-core connecting cables - Part 3: Construction, dimensions and marking of unscreened sheathed low-voltage cables".
Its scope clause reads: This document specifies the comprehensive requirements, construction, dimensions and marking of unscreened sheathed low-voltage cables. This document applies to connecting cables between tractors and trailers, and its temperature range complies with Class A (-40 °C~85 °C) or Class B (-40 °C~100 °C).
Its clauses include terms and definitions; general requirements; construction and dimensions. It was issued by the State Administration for Market Regulation on 2024-10-26 and took effect on 2025-05-01.
Found what you need?
Document preview — GB/T 5054.3-2024
National Standard of the People's Republic of China
- ICS
- 43.040.10
Issued by: State Administration for Market Regulation
Contents
- Foreword...3
- Introduction...5
- 1 Scope...6
- 2 Normative references...6
- 3 Terms and definitions...8
- 4 General requirements...8
- 5 Construction and dimensions...8
- 6 Marking...11
- Appendix A (Informative) Rated cross-sectional areas of cable cores...14
1 Scope
This document specifies the comprehensive requirements, construction, dimensions and marking of unscreened sheathed low-voltage cables.
This document applies to connecting cables between tractors and trailers, and its temperature range complies with Class A (-40 °C~85 °C) or Class B (-40 °C~100 °C).
2 Normative references
The provisions of the following documents constitute the essential clauses of this document through normative references in this text. Among them, for any dated reference, only the version corresponding to that date applies to this document; for any undated reference, the latest version (including all amendments) applies to this document.
ISO 1185 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - 7-pole connector type 24 N (normal) for vehicles with 24 V nominal supply voltage
NOTE. GB/T 5053.1-2006 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - 7-pole connector type 24 N (normal) for vehicles with 24 V nominal supply voltage (ISO 1185.2003, IDT)
ISO 1724 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - 7-pole connector type 12 N (normal) for vehicles with 12 V nominal supply voltage
NOTE. GB/T 5053.2-2006 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - 7-pole connector type 12 N (normal) for vehicles with 12 V nominal supply voltage (ISO 1724.2003, IDT)
ISO 3731 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - 7-pole connector type 24 S (supplementary) for vehicles with 24
ISO 11446-2 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - Part 2.13-pole connectors for vehicles with 12 V nominal supply voltage intended to cross water fords
ISO 12098 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - 15-pole connector for vehicles with 24 V nominal supply voltage
NOTE. GB/T 20717-2006 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - 15-pole connector for vehicles with 24 V nominal supply voltage (ISO 12098.2004,
IDT)
ISO 25981 Road vehicles - Connectors for the electrical connection of towing and towed vehicles - Connectors for electronically monitored charging systems with 12
V or 24 V nominal supply voltage
3 Terms and definitions
There are no terms or definitions that require definition in this document.
ISO and IEC maintain terminological databases for use in standardization at the following addresses.
4 General requirements
Basic performance sheathed cables shall meet the requirements of ISO 4141-1.
High performance sheathed cables shall meet the requirements of ISO 4141-2.
5 Construction and dimensions
5.1 Single-core
5.1.1 General
The core wire shall be composed of multiple strands of fine wires twisted together, and the arrangement sequence of the core wires shall comply with the requirements for any contact arrangement sequence of electrical connectors in the following standards. ISO
3732, ISO 3731, ISO 1185, ISO 1724, ISO 7638-1, ISO 7638-2, ISO 11446-1, ISO
11446-2, ISO 12098, ISO 25981.
NOTE. Appendix A gives an overview of the rated cross-sectional areas of cable cores specified in the above standards.
5.1.2 Additional materials
According to the requirements of the cable construction, the sheath is filled with non- metallic tape or packaging materials, and an inner sheath can also be used.
5.2 Sheath dimensions
5.2.1 Thickness
According to the relevant measurement requirements in ISO 4141-1, the minimum thickness of the cable sheath shall be 1 mm.
5.2.2 Outer diameter
According to the relevant measurement method in ISO 4141-1, the outer diameter of the multi-core cable shall meet the requirements of Table 1.
According to the relevant measurement method in ISO 4141-1, the ellipticity of multi- core cables shall not exceed 10%.
5.3 Coiled cable dimensions
The length symbols of coiled connecting cables are defined as follows.
LB -- the block length or retracted length; the length of the coiled part, excluding the tail straight segment;
LW -- the working length; the length when the coiled cable connects the tractor and trailer without bending, including the tail straight segment;
LEmax -- the maximum allowable extension length; the maximum extension length
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.
Referenced standards
Normative references
ISO 1185 · ISO 1724 · ISO 3731 · ISO 11446 · ISO 12098 · ISO 25981
Cited by
- GB/T 20718.2-2025Road vehicles - Connectors for the electrical connection of towing and towed vehicles (13-pole) - Part 2: 13-pole connectors for vehicles with 12 V nominal supply voltage intended to cross water fords
- GB/T 5054.4-2024Road vehicles - Multi-core connecting cables - Part 4: Test methods and requirements for coiled cable assemblies
- QC/T 1149-2021Special vehicles for transporting large indivisible loads
- QC/T 913-2013General technical specifications for hydraulic suspension trailers
- GB/T 5053.2-2006Road vehicles - Connectors for the electrical connection of towing and towed vehicles. 7-pole connector type 12 N (normal) for vehicles with 12 V nominal supply voltage
How to Download GB/T 5054.3-2024
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 5054.1-2024 — Road vehicles - Multi-core connecting cables - Part 1: Test methods and requirements for basic performance sheathed cables
GB/T 5054.2-2024 — Road vehicles - Multi-core connecting cables - Part 2: Test methods and requirements for high performance sheathed cables
GB/T 5054.4-2024 — Road vehicles - Multi-core connecting cables - Part 4: Test methods and requirements for coiled cable assemblies
Secure payment via Stripe
Payments accepted
GB/T 5054.3-2024
$250.00