GB/T 4854.5-2008Acoustics -- Reference zero for the calibration of audiometric equipment -- Part 5: Reference equivalent threshold sound pressure levels for pure tone in the frequency range 8 kHz to 16 kHz (English PDF)
声学 校准测听设备的基准零级 第5部分:8kHz-16kHz频率范围纯音基准等效阈声压级
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for GB/T 4854.5-2008 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
July 2, 2008
Implementation date
February 1, 2009
Scope
GB/T 4854.5-2008 is the English-translated version of 声学 校准测听设备的基准零级 第5部分:8kHz-16kHz频率范围纯音基准等效阈声压级.
GB/T 4854.5-2008 — This section provides 8kHz ~ 16kHz frequency range pure tone reference equivalent threshold sound pressure levels (RETSPLs), for a particular type ear Air conduction audiometer calibration machine.
NOTE. it gives a description and experimental conditions to determine the reference equivalent threshold sound pressure levels in Appendix A and reference.
Found what you need?
Document preview — GB/T 4854.5-2008
National Standard of the People's Republic of China
- ICS
- 17.140
- Classification
- A 59
Issued by: Standardization Administration of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Technical Requirements
Foreword
GB/T 4854 "acoustic calibration of audiometric equipment - Reference zero" includes eight parts.
--- GB/T 4854.1 acoustic calibration of audiometric equipment - Reference zero for Part 1. the ear headphones pure tone reference equivalent threshold sound Pressure level;
--- GB/T 16402 Acoustics pure tones and insert earphones Reference equivalent threshold sound pressure levels;
--- GB/T 4854.3 acoustic calibration of audiometric equipment - Reference zero - Part 3. pure tones and bone vibrators Reference equivalent threshold force levels;
--- GB/T 4854.4 Acoustics - Reference zero for the calibration of audiometric equipment - Part 4. Reference levels for narrow-band masking noise;
--- GB/T 4854.5 acoustic calibration of audiometric equipment - Reference zero - Part 5. 8kHz ~ 16kHz frequency range of pure tones Reference equivalent threshold sound pressure levels;
--- GB/T 4854.6 Acoustics - Reference zero for the calibration of audiometric equipment - Part 6. short test drive signal reference hearing threshold level;
--- GB/T 4854.7 Section 7 Reference zero acoustic calibrator audiometric equipment. free-field and diffuse - field listening base Quasi hearing threshold;
--- GB/T 4854.8 acoustic calibration of audiometric equipment - Reference zero - Part 8. Headphones pure tone reference equivalent threshold sound Pressure level.
Note. In developing this standard Part 2, our country has not yet formed a series of standards, the standard number is GB/T 16402, in the part of the revision of its Standard will be changed to GB/T 4854.2.
This section GB/T 54854 Part of.
This part identical with ISO 389-5:2006 "Acoustics --- calibration of audiometric equipment - Reference zero --- Part 5. 8kHz ~ 16kHz frequency range pure tone reference equivalent threshold sound pressure levels "(in English).
This section is equivalent to using international standards made editorial changes.
Appendix A of this section and Appendix B is an informative annex.
This section proposed by the Chinese Academy of Sciences.
The acoustics in part by the National Standardization Technical Committee (SAC/TC17) centralized.
This section drafted by. Institute of Otolaryngology, Chinese PLA General Hospital, Chinese Academy of Sciences Institute of Acoustics.
Introduction
National Standard GB extended high frequency audiometry device/T 7341.4 has been promulgated. As the high-frequency range extending calibration audiometry using headphones Adapter with IEC 60318-1 ear simulator used together to form the acoustic coupler calibration middle-ear headphones. The adapter has now become International Standard IEC 60318-2 (will be included in the revised IEC 60318-1). This section describes specific model Headphones and insert earphones reference equivalent threshold sound pressure levels, can be used for these models have been equipped with headphones calibrated audiometer, hearing threshold level in our country Expression measurements values \u200b\u200bconsistent with internationally.
GB/T 4854.5-2008/ISO 389-5:2006 Acoustics - Reference zero for the calibration of audiometric equipment Part 5. 8 k H z ~ 16 k H z frequency Range pure tone reference equivalent threshold sound pressure levels
1 Scope
This section provides 8kHz ~ 16kHz frequency range pure tone reference equivalent threshold sound pressure levels (RETSPLs), for a particular type ear Air conduction audiometer calibration machine.
NOTE. it gives a description and experimental conditions to determine the reference equivalent threshold sound pressure levels in Appendix A and reference.
2 Normative references
The following documents contain provisions which, through reference to GB/T 4854 to the present, constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated references, the latest version applies to this section.
GB/T 4854.1 acoustic calibration of audiometric equipment - Reference zero - Part 1. the ear headphones pure tone reference equivalent threshold sound pressure levels (GB/T 4854.1-2004, ISO 389-1:1998, IDT) GB/T 16402 Acoustics pure tones and insert earphones Reference equivalent threshold sound pressure levels (GB/T 16402-1996, eqv ISO 389-2.
1994)
IEC 60318-11) electro-acoustics simulator head and ear - Part 1. Align the ear headphones ear simulator IEC 60318-2.19982) electro-acoustics simulator head and ear - Part 2. Calibration extended high-frequency audiometry intermediate range headphones Acoustic coupler IEC 607113) and insert earphones measurement clogged ear simulator
3 Terms and Definitions
This part of GB/T 4854.1 and IEC 60318-1 terms and definitions in.
4 Technical Requirements
Reference equivalent threshold sound pressure levels (RETSPLs) headset model and calibration headset with an ear simulator and adapter related. Table 1 to Out (ETYMOTICRESEARCHER-2 with ER1-14A type earplugs) and close to two different types of headphones [insert earphones Predetermined value closed earphones (SENNHEISERHDA200)] of.
Headband SENNHEISERHDA200 type earphones clamping force should be (10.0 ± 1.0) N. When measuring headband clamping force, two ears the distance between the machine should be 145mm; headband center (top) from the midpoint of the center of two headphones to be adjusted to 130mm.
Ear ETYMOTICRESEARCHER-2 plug-in headset, should be deep into a subject's ear canal, so earplugs the outer end of the ear canal flush.
1) is being revised.
2) will be canceled, its content is included in the revised IEC 60318-1.
3) will become the IEC 60318-4.
GB/T 4854.5-2008/ISO 389-5:2006
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 16402Acoustics. Reference equivalent threshold sound pressure levels for pure tones and insert earphones
- GB/T 16402-1996Acoustics. Reference equivalent threshold sound pressure levels for pure tones and insert earphones
GB/T 4854 · GB/T 4854.1 · GB/T 4854.1-2004 · ISO 389 · IEC 60318 · IEC 607113
How to Download GB/T 4854.5-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16402-1996 — Acoustics. Reference equivalent threshold sound pressure levels for pure tones and insert earphones
GB/T 4854.3-2022 — Acoustics - Reference zero for the calibration of audiometric equipment - Part 3: Reference equivalent threshold vibratory force levels for pure tones and bone vibrators
GB/T 4854.4-1999 — Acoustics. Reference zero for the calibration of audiometric equipment. Part 4: Reference levels for narrow-band masking noise
Secure payment via Stripe
Payments accepted
GB/T 4854.5-2008