GB/T 47348-2026Technical specification for the lightning protection of outdoor electronic display systems (English PDF)
室外电子展示系统防雷技术规范
This is a limited preview
Buy now to download the full PDF (21 pages)
Need quotation for your management?
Get a formal quotation for GB/T 47348-2026 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
March 31, 2026
Implementation date
October 1, 2026
Scope
GB/T 47348-2026 is the English-translated version of 室外电子展示系统防雷技术规范.
GB/T 47348-2026 is the Chinese standard "Technical specification for the lightning protection of outdoor electronic display systems".
Its scope clause reads: This document specifies the basic requirements, lightning protection levels, direct lightning strike protection measures, protection against contact voltage, and protection against step lightning strikes for outdoor electronic display systems.
Requirements for voltage protection measures, surge protection measures, and maintenance and management of lightning protection devices are described, along with corresponding testing methods.
This document applies to the lightning protection design, construction, and maintenance of newly built, renovated, or expanded outdoor electronic display systems.
This document does not apply to outdoor electronic display systems installed on mobile carriers. Its clauses include terms and definitions.
Found what you need?
Document preview — GB/T 47348-2026
National Standard of the People's Republic of China
- ICS
- 91.120.40
- Classification
- M 04
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1.Scope
- 2 Normative References
- 3.Terms and Definitions
- 4.Basic Requirements
- 5.Lightning protection level
- 6.Direct lightning strike protection measures
- 7.Measures to prevent contact voltage and step voltage
- 8 Surge protection measures
- 9.Detection methods 8.
- 10.Maintenance and Management of Lightning Protection Devices
- Appendix A (Informative) Schematic Diagram of Outdoor Electronic Display Screen
- Appendix B (Informative) Classification of Outdoor Electronic Display Screen Installation Sites
- Appendix C (Informative) Example 13 of Equipotential Bonding in Indoor Broadcast Control Equipment Room
- Appendix D (Normative) Materials and Minimum Cross-sectional Area of Equipotential Bonding Conductors
- Appendix F (Normative) Selection and Parameters of SPD for Signal Lines
1 Scope
This document specifies the basic requirements, lightning protection levels, direct lightning strike protection measures, protection against contact voltage, and protection against step lightning strikes for outdoor electronic display systems.
Requirements for voltage protection measures, surge protection measures, and maintenance and management of lightning protection devices are described, along with corresponding testing methods.
This document applies to the lightning protection design, construction, and maintenance of newly built, renovated, or expanded outdoor electronic display systems.
This document does not apply to outdoor electronic display systems installed on mobile carriers.
2 Normative references
The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included.
For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies.
This document.
GB/T 18802.352 Low-voltage surge protection components - Part 352.Surge isolation transformers (SITs) for telecommunications and signaling networks
Selection and Use Guidelines
GB/T 21431 Technical Specification for Testing Lightning Protection Devices of Buildings
GB 50057-2010 Code for Design of Lightning Protection of Buildings
GB 50601 Code for Construction and Quality Acceptance of Lightning Protection Engineering for Buildings
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
The system consists of an outdoor electronic display screen, indoor broadcast control facilities, a signal transmission system, and a low-voltage power distribution system.
Note 1.Outdoor electronic displays are divided into freestanding and attached types. See Appendix A for a schematic diagram. The corresponding outdoor electronic display systems are freestanding outdoor electronic displays...
Display system and attached outdoor electronic display system.
Note 2.Common outdoor electronic display systems include electronic information release systems for tourist attractions, electronic advertising systems for buildings, and variable message signs for highways.
Etc.
3.2
Electrical appliances used to limit transient overvoltages and discharge inrush currents.
Note 1.A surge protector contains at least one non-linear element.
Note 2.The SPD has appropriate connecting devices and is a complete assembly component.
[Source. GB/T 18802.11-2020, 3.1.1]
3.3 Class I test
The test was conducted with a peak value equal to 8/20 of the impulse discharge current Iimp and a peak voltage equal to 1.2/50 of the impulse voltage.
[Source. GB/T 18802.11-2020, 3.1.34.1] […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 18802.352Components for low-voltage surge protection - Part 352: Selection and application principles for telecommunications and signalling network surge isolation transformers (SITs)
- GB/T 21431Technical specification for inspection of lightning protection systems of buildings
- GB 50057-2010Code for design protection of structures against lightning
- GB 50601Code for construction and quality acceptance for lightning protection engineering of structures
How to Download GB/T 47348-2026
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 50057-2010 — Code for design protection of structures against lightning
GB 50601-2010 — Code for construction and quality acceptance for lightning protection engineering of structures
GB/T 18802.352-2022 — Components for low-voltage surge protection - Part 352: Selection and application principles for telecommunications and signalling network surge isolation transformers (SITs)