GB/T 44232-2024Technical specification for battery charge discharge controller of stand-alone photovoltaic system (English PDF)

独立光伏系统用蓄电池充放电控制器技术规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (13 pages)

Need quotation for your management?

Get a formal quotation for GB/T 44232-2024 in 30 minutes.

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

August 23, 2024

Implementation date

August 23, 2024

Scope

GB/T 44232-2024 is the English-translated version of 独立光伏系统用蓄电池充放电控制器技术规范.

GB/T 44232-2024 is the Chinese national technical specification for battery charge and discharge controllers of stand-alone photovoltaic systems.

It defines the terms for these controllers and sets technical requirements for functions such as full-battery protection and recovery, over-discharge protection and recovery, temperature compensation, static power consumption, charge and discharge conversion efficiency, static MPPT tracking efficiency, measurement accuracy, protection and environmental adaptability, and it describes the matching test methods.

It applies to controllers for stand-alone photovoltaic systems with voltage levels of 6 V to 60 V and rated power up to 12 kW. Battery types named are lead-acid, gel and lithium.

Other systems may use it for reference. Issued and applicable from 23 August 2024, it replaces no earlier edition.

Found what you need?

Document preview — GB/T 44232-2024

National Standard of the People's Republic of China

ICS
27.160
Classification
F 12

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting.

1 Scope

This document defines the terms and definitions of battery charge and discharge controllers for independent photovoltaic systems (hereinafter referred to as controllers), and specifies the controller The device has the functions of battery full protection and recovery, battery over discharge protection and recovery, temperature compensation, static power consumption, charge and discharge conversion Efficiency, static MPPT tracking efficiency, measurement accuracy, protection board (lithium battery) activation function, protection function, environmental adaptability, protection, etc.

The technical requirements of the level are given and the corresponding test methods are described.

This document applies to battery charge and discharge control for independent photovoltaic systems with voltage levels of 6 V to 60 V and rated power not exceeding 12 kW The battery types include lead-acid batteries, gel batteries and lithium batteries. Other types of independent photovoltaic systems use battery charge and discharge control Device for reference use.

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document.

For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies. in this document.

GB/T 2423.1 Environmental testing for electric and electronic products Part 2: Test methods Test A. Low temperature

GB/T 2423.2 Environmental testing for electric and electronic products Part 2: Test methods Test B. High temperature

GB/T 2423.3-2016 Environmental testing Part 2: Test methods Test Cab. Steady state damp heat test

GB/T 2423.4 Environmental testing for electric and electronic products Part 2: Test methods Test Db. Cyclic damp heat (12 h 12 h cycle)

GB/T 2423.17 Environmental testing for electric and electronic products Part 2: Test methods Test Ka. Salt spray

GB/T 4208 Enclosure protection degree (IP code)

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 Battery charge and discharge charge discharge controller

Power electronics that control the charging and discharging of batteries in solar photovoltaic systems.

3.2 Bulk charge

In the initial charging stage, the battery is charged with the maximum working current that the photovoltaic array can provide or the rated charging current of the controller. The pool can be filled as quickly as possible.

3.3 Bulk voltage

The threshold voltage from high current charging to the next charging stage.

Note: Also called boost charging voltage.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 44232-2024

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
13 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 44232-2024

$300.00