GB/T 43279.3-2023Molecular in vitro diagnostic examinations - Specifications for pre-examination processes for venous whole blood - Part 3: Isolated circulating cell free DNA from plasma (English PDF)

分子体外诊断检验 静脉全血检验前过程的规范 第3部分:分离血浆循环游离DNA

Preview PDF

This is a limited preview

Buy now to download the full PDF (13 pages)

Need quotation for your management?

Get a formal quotation for GB/T 43279.3-2023 in 30 minutes.

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

November 27, 2023

Implementation date

June 1, 2024

Scope

GB/T 43279.3-2023 is the English-translated version of 分子体外诊断检验 静脉全血检验前过程的规范 第3部分:分离血浆循环游离DNA.

GB/T 43279.3-2023 — This document provides operational guidelines for the pre-test phase of venous whole blood specimens used for plasma circulating cell-free DNA (ccfDNA) testing, including Including specimen handling, storage, processing and recording: This document covers specimens collected with venous whole blood collection tubes: This document is applicable to molecular in vitro diagnostic tests performed by medical laboratories and is also applicable to laboratory customers, in vitro diagnostic developers and manufacturers: Molecular in vitro diagnostic tests conducted by vendors, biobanks, institutions and commercial organizations engaged in biomedical research, and regulatory agencies: This document does not cover specific methods for stabilizing genomic DNA in blood: For information on genomic DNA in blood, see ISO :20186-2: This document does not address specific methods for DNA preservation in circulating exosomes: NOTE: ccfDNA obtained from blood by the procedures cited in this document may contain DNA from exosomes [10-11]: This document does not address the presence of pathogen DNA in blood:

Found what you need?

Document preview — GB/T 43279.3-2023

National Standard of the People's Republic of China

ICS
11.100.10
Classification
C 30

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 General considerations
  • 5 Outside the laboratory
  • 5.1 Specimen collection
  • 5.2 Shipping requirements
  • 6 Inside the laboratory
  • 6.1 Specimen Receipt
  • 6.2 Storage requirements for blood specimens
  • 6.3 Plasma preparation
  • 6.4 Storage requirements for plasma samples
  • 6.5 Isolation of ccfDNA
  • 6.6 Content and quality assessment of isolated ccfDNA
  • 6.7 Storage of isolated ccfDNA
  • Appendix A (informative) Effect of pre-test steps on circulating free DNA profile in venous whole blood plasma
  • A:1 Changes in ccfDNA profile in blood after blood collection
  • A:2 Impact of ccfDNA profile changes on the detection of epidermal growth factor receptor mutants in plasma
  • Reference

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents" Drafting:

This document is Part 3 of GB/T 43279 "Specifications for pre-examination of venous whole blood for molecular in vitro diagnostic testing": GB/T 43279 the following sections have been published:

---Part 1: Isolation of cellular RNA;

---Part 2: Isolation of genomic DNA;

---Part 3: Isolation of plasma circulating cell-free DNA:

This document is equivalent to ISO :20186-3:2019 "Molecular in vitro diagnostic testing venous whole blood pre-test process specifications Part 3: Points Circulating cell-free DNA from plasma:

Please note that some content in this document may be subject to patents: The publisher of this document assumes no responsibility for identifying patents:

Introduction

The emergence of molecular in vitro diagnostics has enabled significant advances in medicine: However, the accuracy of molecular in vitro diagnostic results is affected by many factors:

For example, irregular operations during specimen collection, transportation, storage, and processing before testing may cause the content of these molecules to and/or the integrity has changed significantly, and subsequent test analysis is affected by human factors in the pre-test process and cannot fully reflect the patient's true condition:

The actual state affects the results of diagnosis or research:

After blood collection, the circulating cell-free DNA (ccfDNA) profile will undergo significant changes (such as the release of cellular genomic DNA in the blood, ccfDNA degradation and fragmentation and changes in ccfDNA content): Therefore, specific measures need to be taken to ensure high-quality ccfDNA test samples Book: Studies have been conducted to identify these important influencing factors [24]:

The entire process from specimen collection to ccfDNA testing needs to be standardized:

This document standardizes the steps in the pre-assay process for the preparation of circulating cell-free DNA from venous whole blood:

GB/T 43279 specifies the requirements for standardized pre-test procedures for venous whole blood molecular in vitro diagnostic tests: GB/T 43279 it is planned to consist of three parts:

---Part 1: Isolating cellular RNA: The purpose is to standardize the standardized pre-test steps for RNA testing in venous whole blood testing:

Steps are taken to reduce changes and modifications in RNA profiles and ensure the validity and reliability of subsequent test results:

---Part 2: Isolating genomic DNA: The purpose is to standardize the standardized pre-test operations for DNA testing in venous whole blood testing steps to reduce the impact of DNA profile changes and modifications on subsequent testing:

---Part 3: Isolation of plasma circulating cell-free DNA: The purpose is to standardize the standards for circulating cell-free DNA testing in venous whole blood testing:

Standardize the pre-test steps to reduce the impact of changes and modifications in circulating free DNA on subsequent tests:

Molecular in vitro diagnostic test venous whole blood pre-test process Specification Part 3: Isolation of circulating cell-free DNA from plasma

1 Scope

This document provides operational guidelines for the pre-test phase of venous whole blood specimens used for plasma circulating cell-free DNA (ccfDNA) testing, including Including specimen handling, storage, processing and recording: This document covers specimens collected with venous whole blood collection tubes:

This document is applicable to molecular in vitro diagnostic tests performed by medical laboratories and is also applicable to laboratory customers, in vitro diagnostic developers and manufacturers:

Molecular in vitro diagnostic tests conducted by vendors, biobanks, institutions and commercial organizations engaged in biomedical research, and regulatory agencies:

This document does not cover specific methods for stabilizing genomic DNA in blood: For information on genomic DNA in blood, see ISO :20186-2:

This document does not address specific methods for DNA preservation in circulating exosomes:

NOTE: ccfDNA obtained from blood by the procedures cited in this document may contain DNA from exosomes [10-11]:

This document does not address the presence of pathogen DNA in blood:

2 Normative reference documents

The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, the dated quotations for undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document:

GB/T 22576.1-2018 Medical laboratory quality and capability requirements Part 1: General requirements (ISO 15189:2012, IDT)

3 Terms and definitions

The following terms and definitions apply to this document:

Terminology databases for standardization maintained by ISO and IEC at the following address:

---ISO online browsing platform: http://www:iso:org/obp;

analyteanalyte

The component represented by the name of the measurand:

[Source: GB/T 21415-2008, 3:2, with modifications] 3.2 backflow the flow of liquid in the opposite direction to the usual or desired direction:

blood collection device bloodcollectionset A device specifically designed for venipuncture consisting of a stainless steel beveled needle and tubing (tubing) with plastic wings and connectors:

Note: This connector is connected to another blood collection device, such as a blood collection tube (3:4):

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.

How to Download GB/T 43279.3-2023

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
13 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 43279.3-2023

$300.00