GB/T 42886-2023Microscopes - Microscopes with digital imaging displays - Information provided to the user regarding imaging performance (English PDF)
显微镜 数字成像显示显微镜 提供给用户的成像性能信息
This is a limited preview
Buy now to download the full PDF (21 pages)
Need quotation for your management?
Get a formal quotation for GB/T 42886-2023 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
August 6, 2023
Implementation date
March 1, 2024
Scope
GB/T 42886-2023 is the English-translated version of 显微镜 数字成像显示显微镜 提供给用户的成像性能信息.
This document defines the terms, symbols and abbreviations used for the imaging performance information that a microscope with a digital imaging display gives its user, and specifies the magnification, the limit of resolution, the range of useful magnification, the object field of view, the depth of field and the information the manufacturer has to provide.
The document applies to the design, manufacture and quality assessment of microscopes with digital imaging displays.
Found what you need?
Document preview — GB/T 42886-2023
National Standard of the People's Republic of China
- ICS
- 37.020
- Classification
- N 32
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative reference documents
- 3 Terms and Definitions
- 4 Symbols and abbreviations
- 5 Magnification
- 6 Ultimate resolution ability
- 7 Effective zoom range
- 8 Object field of view
- 9 Depth of field
- 10 Information provided by the manufacturer to users
- Appendix A (informative) Examples of information provided to users
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents" Drafting.
This document has been modified to adopt ISO 18221:2016 "Microscope digital imaging display imaging performance information provided to users by microscopes".
The technical differences between this document and ISO 18221:2016 and their reasons are as follows.
---The content of the scope has been changed (see Chapter 1) to conform to my country's standard terminology habits;
---Added normative reference to GB/T 22059 (see Chapter 3) to comply with my country's standard technical requirements;
---Replaced ISO 10934-1 and ISO 10934-2 (see Chapter 3) with normatively quoted GB/T 27668 to comply with our national standards Quasi-technical requirements;
---Formula (8) and formula (9) have been changed to adapt to my country's technical requirements and improve operability (see 8.1 and 8.2). The following editorial changes have been made to this document.
---Deleted the "Note" in Chapter 3;
---Corrected the serial numbers of mathematical formulas in international standards, changing "(7), (8), (9), (10), (11), (12)" to "(6), (7), (8), (9), (10), (11)";
---Reference removed.
Introduction
With the development of digital information technology, digital imaging display microscopes are playing an increasingly important role in the field of microscopy and are widely used.
It is used in fields such as scientific research, teaching, medical care and manufacturing, and is often equipped with digital imaging displays in various optical, mechanical and electrical integration equipment. microscopy system. In the modern optical microscope industry, there are a large number of companies that produce digital imaging display microscopes, and the products have different performance and types.
Many categories. Therefore, the various parameters of digital imaging display microscopes produced by different companies should be standardized and unified so that their related components can be consistent.
Mutual replacement is very beneficial to improving the efficiency of optical microscopes, accelerating scientific research and integrating product development.
In view of the above reasons, in order to improve enterprise production efficiency, promote collaborative production among enterprises, and improve scientific research projects and new product development To increase the speed of research and development, it is necessary to standardize and normalize the various imaging performance information provided to users by digital imaging display microscopes.
1 Scope
This document defines the terms and definitions, symbols and abbreviations for imaging performance information provided to users by digital imaging display microscopes, and regulates The magnification rate, ultimate resolving power, effective magnification range, object field of view, depth of field and the information provided by the manufacturer to the user are specified.
This document applies to the design, manufacturing and quality assessment of digital imaging display microscopes.
2 Normative reference documents
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, the dated quotations For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document.
GB/T 22059 Microscope magnification values, tolerances and symbols (GB/T 22059-2018, ISO 8039:2014, MOD)
GB/T 27668 Microscope optical microscopy terminology (GB/T 27668-2023, ISO 10934:2020, MOD)
3 Terms and definitions
The terms and definitions defined in GB/T 22059 and GB/T 27668 and the following apply to this document.
3.1 Microscope with digital imaging display
An instrument consisting of an objective lens, an image sensor, and a digital display used to display minute details that are invisible to the naked eye.
Note: The system can include image enhancement, image analysis and archiving, etc.
3.2 Image sensor
A device that converts optical imaging into digital images.
3.3 Digital display
An output device for the visual display of digital images and other information.
3.4 Resolvingpowerlimit
The maximum spatial frequency that can be distinguished in object space, expressed in lp/mm.
Note: Due to factors such as reduced contrast and moiré pattern, the actual obtained resolution power will always be lower than the ultimate resolution power. Also, it depends on the sensor The type, structure of the object, lighting and other reasons.
3.5 Pixel pitch
The distance between the centers of adjacent pixels (picture elements) in an image sensor or digital display.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.
Referenced standards
How to Download GB/T 42886-2023
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 22059-2008 — Microscopes - Magnifying power
GB/T 22059-2018 — Microscopes -- Values, tolerances and symbols for magnification
GB/T 27668.1-2011 — Microscopes - Vocabulary for light microscopy
Secure payment via Stripe
Payments accepted
GB/T 42886-2023
$300.00