Valid

GB/T 42513.3-2023Methods for chemical analysis of nickel alloys - Part 3: Determination of aluminium content - Nitrous oxide- flame atomic absorption spectrometry and inductively coupled plasma atomic emission spectrometry (English PDF)

镍合金化学分析方法 第3部分:铝含量的测定 一氧化二氮-火焰原子吸收光谱法和电感耦合等离子体原子发射光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (14 pages)

Need quotation for your management?

Get a formal quotation for GB/T 42513.3-2023 in 30 minutes.

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

November 27, 2023

Implementation date

June 1, 2024

Scope

GB/T 42513.3-2023 is the English-translated version of 镍合金化学分析方法 第3部分:铝含量的测定 一氧化二氮-火焰原子吸收光谱法和电感耦合等离子体原子发射光谱法.

GB/T 42513.3-2023 — This document describes the determination of nickel alloys by nitrous oxide-flame atomic absorption spectrometry and inductively coupled plasma atomic emission spectrometry: method for medium aluminum content: This document applies to the determination of aluminum content in nickel alloys, Method 1: Determination range of nitrous oxide-flame atomic absorption spectrometry (mass Fraction) is 0.2%~4%; Method 2: The measurement range (mass fraction) of inductively coupled plasma atomic emission spectrometry is 0.010%~ 7.00%:

Found what you need?

Document preview — GB/T 42513.3-2023

National Standard of the People's Republic of China

ICS
77.120.40
Classification
H 13

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative reference documents
  • 3 Terms and definitions
  • 4 Method 1: Nitrous oxide-flame atomic absorption spectrometry

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents" Drafting:

This document is Part 3 of GB/T 42513 "Chemical Analysis Methods for Nickel Alloys": GB/T 42513 has released the following parts:

---Part 1: Determination of chromium content by ferrous ammonium sulfate potentiometric titration method;

---Part 2: Determination of phosphorus content by molybdenum blue spectrophotometry;

---Part 3: Determination of aluminum content by nitrous oxide-flame atomic absorption spectrometry and inductively coupled plasma atomic emission light spectrometry;

---Part 4: Determination of silicon content by nitrous oxide-flame atomic absorption spectrometry and molybdenum blue spectrophotometry;

---Part 5: Determination of vanadium content by nitrous oxide-flame atomic absorption spectrometry and inductively coupled plasma atomic emission light spectrum method:

This document has been modified to adopt ISO 7530-7:1992 "Nickel Alloy Flame Atomic Absorption Spectrometry Part 7: Determination of Aluminum Content":

Compared with ISO 7530-7:1992, this document has many adjustments in structure: A comparison list of structural number changes between the two documents See Appendix A:

Compared with ISO 7530-7:1992, there are many technical differences between this document and the clauses involved in the outer margins:

Straight single lines (|) are marked: A list of these technical differences and their causes is provided in Appendix B:

The following editorial changes have been made to this document:

---In order to coordinate with the existing standards, the name of the standard is changed to "Chemical Analysis Methods for Nickel Alloys Part 3: Determination of Aluminum Content - Oxygen Nitrogen-flame atomic absorption spectrometry and inductively coupled plasma atomic emission spectrometry";

---Added a note about hydrolysis precipitation in 4:5:5:2 Secondary Dilution:

Please note that some content in this document may be subject to patents: The publisher of this document assumes no responsibility for identifying patents:

Introduction

Nickel alloys are commonly used in instrumentation, electronic communications, pressure vessels, corrosion-resistant devices, and are widely used in aerospace and high-end special purposes:

Machinery and equipment manufacturing and other industries are one of the important metal raw materials for industrial development: International standards for chemical analysis methods of nickel alloys have been published for dozens of in:2017, with the progress of my country's industry, the demand for the production, import and export of high-end nickel alloy materials increased: To this end, international standards were transformed into national standards:

It is of great significance to assist the development and upgrading of non-ferrous industry and the development of domestic manufacturing industry: GB/T 42513 "Chemical Analysis Methods for Nickel Alloys" Purpose in establishing a complete and practical standard method for testing chromium, phosphorus, niobium, molybdenum, aluminum, vanadium, silicon, cobalt, copper and other elements in nickel alloys, transform it into the following international standards:

---ISO 7592:2017 Determination of chromium content in nickel alloys by ferrous ammonium sulfate potentiometric titration method;

---ISO 9388:1992 Determination of phosphorus content in nickel alloys by molybdenum blue spectrophotometry;

---ISO 7530-7:1992 Flame atomic absorption spectrometry analysis of nickel alloys Part 7: Determination of aluminum content;

---ISO 7530-8:1992 Flame atomic absorption spectrometry analysis of nickel alloys Part 8: Determination of silicon content;

---ISO 7530-9:1993 Flame atomic absorption spectrometry analysis of nickel alloys Part 9: Determination of vanadium content;

---ISO 11435:2011 Determination of molybdenum content in nickel alloys by inductively coupled plasma atomic emission spectrometry;

---ISO 7530:2015 Flame atomic absorption spectrometry analysis of nickel alloys Part 1: Determination of cobalt, chromium, copper, iron and manganese content;

---ISO 22033:2011 Determination of niobium content in nickel alloys by inductively coupled plasma atomic emission spectrometry;

---ISO 11436:1993 Determination of total boron content in nickel and nickel alloys Curcumin spectrophotometric method;

---ISO 23166:2018 Determination of tantalum content in nickel alloys by inductively coupled plasma atomic emission spectrometry:

GB/T 42513 is planned to consist of 13 parts:

---Part 1: Determination of chromium content by ferrous ammonium sulfate potentiometric titration method:

---Part 2: Determination of phosphorus content by molybdenum blue spectrophotometry:

---Part 3: Determination of aluminum content by nitrous oxide-flame atomic absorption spectrometry and inductively coupled plasma atomic emission light spectrum method:

---Part 4: Determination of silicon content by nitrous oxide-flame atomic absorption spectrometry and molybdenum blue spectrophotometry:

---Part 5: Determination of vanadium content by nitrous oxide-flame atomic absorption spectrometry and inductively coupled plasma atomic emission light spectrum method:

---Part 6: Determination of molybdenum content by inductively coupled plasma atomic emission spectrometry:

---Part 7: Determination of cobalt, chromium, copper, iron and manganese content by flame atomic absorption spectrometry:

---Part 8: Determination of niobium content by inductively coupled plasma atomic emission spectrometry:

---Part 9: Determination of total boron content of curcumin spectrophotometrically:

---Part 10: Determination of trace element content by glow discharge mass spectrometry:

---Part 11: Determination of silicon, manganese, phosphorus, chromium, nickel, copper, molybdenum, cobalt, iron, aluminum, vanadium, titanium, tungsten and niobium content by X-ray fluorescence spectrometry (common law):

---Part 12: Determination of tantalum content by inductively coupled plasma atomic emission spectrometry:

---Part 13: Determination of oxygen, nitrogen and hydrogen content: Inert gas melting - thermal conductivity method/infrared absorption method:

Adding aluminum to nickel alloys can make the material have suitable strength and hardness, as well as a lower melting point and higher electrical conductivity, which is used to modify the alloy:

There are demanding areas of shape memory: This document can promote the progress of my country's nickel alloy testing technology and ensure that industry practitioners There are standards to follow in the process of application, scientific research and testing, which fill the gap in the determination method of aluminum content in nickel alloys in my country:

Nickel alloy chemical analysis method Part 3: Determination of aluminum content Nitrous oxide-flame atomic absorption spectrometry and Inductively coupled plasma atomic emission spectrometry Warning---Personnel using this document should have regular laboratory work experience: This document does not address all possible security issues question: Users are responsible for taking appropriate safety and health measures and ensuring compliance with the conditions stipulated in relevant national regulations:

1 Scope

This document describes the determination of nickel alloys by nitrous oxide-flame atomic absorption spectrometry and inductively coupled plasma atomic emission spectrometry:

method for medium aluminum content:

This document applies to the determination of aluminum content in nickel alloys, Method 1: Determination range of nitrous oxide-flame atomic absorption spectrometry (mass Fraction) is 0.2%~4%; Method 2: The measurement range (mass fraction) of inductively coupled plasma atomic emission spectrometry is 0.010%~ 7.00%:

2 Normative reference documents

This document has no normative references:

3 Terms and definitions

There are no terms or definitions to be defined in this document:

4 Method 1: Nitrous oxide-flame atomic absorption spectrometry

4.1 Principle

The sample is dissolved in acid, and an ionization inhibitor (if necessary) is added to the nitric acid-hydrochloric acid mixed acid medium: This is the test solution: Dissolve the test the liquid is sucked into the nitrous oxide-acetylene flame of the atomic absorption spectrometer, and the absorbance of aluminum is measured at the wavelength of 309:3nm of the atomic absorption spectrometer:

Degree, use the working curve method to calculate the aluminum content:

4.2 Reagents

Warning: Hydrofluoric acid (4:2:3) is extremely irritating and corrosive to skin and mucous membranes and can cause severe skin burns that will heal slowly: like in case of contact with skin, rinse with water and seek medical advice:

Mixed acids (4:2:7) are unstable and highly corrosive: Toxic gas (chlorine) will be released when left standing, so preparation should be done in a fume hood:

carried out and should not be stored in closed containers:

Unless otherwise stated, only approved analytical grade reagents and distilled water or water of equivalent purity are used during analysis:

4.2.1 Nitric acid: rho=1:41g/mL:

4.2.2 Hydrochloric acid: rho=1:18g/mL:

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.

How to Download GB/T 42513.3-2023

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
14 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 42513.3-2023

$300.00