GB/T 41752-2022Gas analysis - Investigation and treatment of analytical bias (English PDF)
Also coversGBT41752-2022
Open the GB/T 41752-2022 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
October 12, 2022
Implementation date
October 12, 2022
Scope
GB/T 41752-2022 (Gas analysis - Investigation and treatment of analytical bias) is available as an English-translated PDF.
GB/T 41752-2022 — This document describes the analysis and correction of bias (systematic error) in gas analysis procedures using a reference gas mixture or a reference analysis procedure. difference), and a general method for assessing the uncertainty of the corrected value. The main sources of (and contributors to) analytical procedure bias are instrument drift and matrix interferences, which typically vary with analyte concentration. Therefore, this document describes the following two methods. --- Drift analysis and correction of analytical systems with limited stability; ---For a stable analysis system with determined gas sample composition, its bias can be used in subsequent method development and analysis after research and mastery used in method validation studies. This document establishes two procedures applicable to the analysis of system effects. a) retrospectively model observed deviations and correct their effects; b) Averaging system effects and expanding uncertainties. Usually, the first procedure requires more work, but can obtain smaller uncertainties. For ease of use, the methods described in this document are all used to analyze gas composition procedures, for example, the concentration of a specific analyte in a mixed gas measurement procedure. These methods are equally applicable to the measurement of physical or chemical properties of pure or mixed gases in relation to gas analysis.
Document preview — GB/T 41752-2022
National Standard of the People's Republic of China
- ICS
- 71.100.20
- Classification
- G 86
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Preface
- Introduction
- 1 Scope1
- 2 Normative references1
- 3 Terms and Definitions1
- 4 symbols2
foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules for Standardization Documents"
drafting.
This document is modified to adopt ISO 15796.2005 "Research and Treatment of Analysis Bias in Gas Analysis".
Compared with ISO 15796.2005, this document has made the following structural adjustments.
--- A chapter on normative references has been added;
--- Adjust the symbol descriptions in 5.2.1.1 and 5.2.2.1 to Chapter 4.
The technical differences between this document and ISO 15796.2005 and their reasons are as follows.
---Change the angle brackets (such as < x >) representing the average value in the text to an overscore (such as x), because the overscore is common in our country
The symbolic expression of the average value of ;
---Change the term "traceability" to "measurement traceability", the term "traceability" comes from the term in the old version of VIM
--- Change "d >2u[d]" in "multiplicative drift correction" to "d<=2u[d]" (see 5.3.3), here is the errata;
--- Changed the formula (32) (see 6.2.3.3), here is the errata;
--- Changed the formula (39) (see 6.3.4), here is the errata.
Please note that some contents of this document may refer to patents. The issuing agency of this document assumes no responsibility for identifying patents.
Introduction
Metrological traceability is key to quality assurance in gas analysis. Metrological traceability usually refers to uninterrupted calibration through documentation
Chain, the property that links a measurement result to a measurement reference standard. If a measurement proves to be insignificant through an uninterrupted chain of comparisons
Significant bias means that the measurement result has metrological traceability within the specified uncertainty range. Metrological traceability through having a clear measurement
It is reflected in the analytical procedure of the amount concentration range and matrix composition, rather than the result of a single measurement. Measurement of relevant components by an analytical procedure has been traced
If it can be shown that the measurement results are not biased, or the bias has been corrected, then the analytical procedure can be regarded as having a representative sample of the source.
traceability. A representative sample can be a reference gas mixture or a specific sample measured in parallel using a reference analytical procedure.
"Bias" is an estimate of what we usually call "systematic error". "Systematic error" together with "random error" constitutes measurement error.
"Systematic error" means that component of measurement error that remains constant or varies in a predictable manner across repeated measurements, and is generally determined by imperfections in the analytical procedure.
It is easy to introduce, and correction compensation can be used for known system errors. ISO 15796 gives the common types of "bias" in gas analysis respectively
Corresponding research and processing methods have been proposed, which has a significant guiding role for workers in the field of gas analysis.
In this document, the term "concentration" has two meanings.
--- As a general term in gas composition analysis, replace the term "content" (see ISO 7504 [4]);
--- As a general alternative term for a specific analyte in gas composition analysis, such as. the mass concentration or mole fraction of a specific analyte (see
ISO 7504[4]).
Research and Treatment of Analytical Bias in Gas Analysis
1 Scope
This document describes the analysis and correction of bias (systematic error) in gas analysis procedures using a reference gas mixture or a reference analysis procedure.
difference), and a general method for assessing the uncertainty of the corrected value.
The main sources of (and contributors to) analytical procedure bias are instrument drift and matrix interferences, which typically vary with analyte concentration.
Therefore, this document describes the following two methods.
--- Drift analysis and correction of analytical systems with limited stability;
---For a stable analysis system with determined gas sample composition, its bias can be used in subsequent method development and analysis after research and mastery
used in method validation studies.
This document establishes two procedures applicable to the analysis of system effects.
a) retrospectively model observed deviations and correct their effects;
b) Averaging system effects and expanding uncertainties.
Usually, the first procedure requires more work, but can obtain smaller uncertainties.
For ease of use, the methods described in this document are all used to analyze gas composition procedures, for example, the concentration of a specific analyte in a mixed gas
measurement procedure. These methods are equally applicable to the measurement of physical or chemical properties of pure or mixed gases in relation to gas analysis.
2 Normative references
The contents of the following documents constitute the essential provisions of this document through normative references in the text. Among them, dated references
For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to
this document.
GB/T 6379.3 Accuracy of measurement methods and results (trueness and precision) Part 3.Standard measurement method precision
Intermediate measurement (GB/T 6379.3-2012, ISO 5725-3.1994, IDT)
GB/T 10628 Determination and verification comparison method of gas analysis and calibration gas mixture composition (GB/T 10628-2008,
ISO 6143.2001, IDT)
GB/T 27418-2017 Evaluation and Expression of Measurement Uncertainty (ISO /IEC Guide98-3.2008, MOD)
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
bias
An estimate of the systematic error.
Note. Since the true value of the measurand cannot be known exactly, the systematic error cannot be accurately measured and can only be estimated using reference values.
3.2
correction
The procedure for making adjustments to uncorrected measurements to compensate for systematic errors.
Note 1 to entry. A procedure for adjusting uncorrected measurements to compensate for systematic errors. Since the systematic error cannot be fully known, this compensation does not
completely.
Note 2.In ISO /IEC Guide99 [5], the meaning of this term is different.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 6379.3 · GB/T 6379.3-2012 · ISO 5725 · GB/T 10628 · GB/T 10628-2008 · ISO 6143.2001 · GB/T 27418-2017
How to Buy GB/T 41752-2022
- 1Add to cart. Click the "Buy GB/T 41752-2022" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 46830.2-2026 — Plastics - Liquid crystal polymer (LCP) moulding and extrusion materials - Part 2: Preparation of test specimens and determination of properties
GB/T 28593-2026 — Sand and dust weather warning levels
GB/T 19608.3-2026 — Classification of special environmental conditions - Part 3: Plateau
Secure payment via Stripe
Payments accepted
GB/T 41752-2022
$470.00