Valid

GB/T 41559-2022Textiles—Determination of isothiazolone compounds (English PDF)

纺织品 异噻唑啉酮类化合物的测定

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 41559-2022 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

July 11, 2022

Implementation date

February 1, 2023

Scope

GB/T 41559-2022 is the English-translated version of 纺织品 异噻唑啉酮类化合物的测定.

GB/T 41559-2022 is the Chinese test method for seven isothiazolone compounds in textiles.

The specimen is extracted with methanol under ultrasound, the extract is filtered through a membrane and the compounds are measured either by high performance liquid chromatography with tandem mass spectrometry or by high performance liquid chromatography with a diode array detector, quantification being by the external standard method.

It specifies the reagents and materials, the instruments, the analysis steps, how the result is calculated and expressed, the precision and the content of the test report, with limits of quantification of 0.1 mg/kg for HPLC-MS/MS and 1.0 mg/kg for HPLC-DAD.

A normative annex carries the chemical information of the reference materials. It applies to textile products of all kinds, cites GB/T 6682, was issued on 11 July 2022 and has applied since 1 February 2023.

Found what you need?

Document preview — GB/T 41559-2022

National Standard of the People's Republic of China

ICS
59.080.01
Classification
W 04

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Terms and definitions4
  • 4 Principle4
  • 5 Reagents and materials4
  • 6 Instruments5
  • 7 Analysis steps5
  • 8 Result calculation and expression7
  • 9 Limit of quantitation8
  • 10 Precision8
  • 11 Test report8
  • Annex A (normative) Chemical information of isothiazolone reference materials9
  • Annex B (informative) Instrument analysis conditions10
  • Annex C (informative) Multiple reaction monitoring chart (MRM) of isothiazolone standard substances13
  • Annex D (informative) HPLC-DAD chromatograms and UV spectra of isothiazolone standard substances14

1 Scope

This document describes the test method that uses high performance liquid chromatography-tandem mass spectrometer (HPLC-MS/MS) or high performance liquid chromatography-diode array detector (HPLC-DAD) to determine 7 isothiazolone compounds in textiles.

This document applies to various textile products.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB/T 6682, Water for analytical laboratory use - Specification and test methods

3 Terms and definitions

There are no terms and definitions that need to be defined in this document.

4 Principle

The specimen is extracted with methanol by ultrasonic. The extract is filtered through a membrane. Use high performance liquid chromatography-tandem mass spectrometer (HPLC-MS/MS) or high performance liquid chromatography-diode array detector (HPLC-DAD) to determine. Use external standard method for quantification.

5 Reagents and materials

Unless otherwise specified, only analytically pure reagents are used, and the water is grade one water in accordance with GB/T 6682.

5.1 Methanol: Chromatographically pure.

5.2 Formic acid: Chromatographic pure; purity >=98.0%.

5.3 Formic acid solution: 0.1%. Measure 1mL of formic acid (5.2). Dissolve in water and dilute to 1000mL. Shake well.

5.4 7 kinds of isothiazolone reference products: Purity >=95%, in line with the provisions of Annex A.

5.5 Single-component standard stock solution: Accurately and separately weigh an appropriate amount of each isothiazolone separately product (5.4). Use methanol (5.1) to respectively prepare the standard stock solution of which the concentration is about 1000mg/L. NOTE: The standard stock solution shall be stored in a refrigerator at 0°C~4°C, protected from light. It is valid for 6 months.

5.6 Series mixed standard working solutions: Prepare as needed. Respectively pipette a certain volume of 7 isothiazolone standard stock solutions (5.5). Use methanol (5.1) to dilute step by step into a series of mixed standard working solutions of different concentrations. For example, When using HPLC-MS/MS, the concentrations are 2.0µg/L, 10.0µg/L, 50.0µg/L, 100.0µg/L, 500.0µg/L. When using HPLC-DAD, the concentrations are 0.2mg/L, 1.0mg/L, 5.0mg/L, 10.0mg/L, and 50.0mg/L. NOTE: The mixed standard working solution shall be stored in a refrigerator at 0°C~4°C, protected from light. It is valid for 1 month.

5.7 Membrane: Organic phase needle type.

6 Instruments

6.1 Analytical balance: Resolution is 0.01g and 0.1mg.

6.2 Reaction bottle: Tubular, with airtight stopper, about 50mL, made of hard glass.

6.3 Ultrasonic generator: The working frequency is 40kHz. The temperature control range is (40±5)°C.

6.4 High performance liquid chromatography-tandem mass spectrometer (HPLC-MS/MS): Equipped with an electrospray ionization source (ESI).

6.5 High performance liquid chromatograph (HPLC-DAD): Equipped with a diode array detector (DAD).

7 Analysis steps

7.1 Specimen preparation and handling

Take a representative specimen. Cut into pieces about 5mm x 5mm. Mix well. Use the balance (6.1) to accurately weigh about 1g of the above specimen, accurate to 0.01g.

7.2

absorption spectrum is consistent with the standard material, and the maximum absorption wavelength deviation is within the range of ±2nm, THEN the target analyte can be judged to be detected.

The HPLC chromatograms and UV absorption spectra of 7 isothiazolones obtained under the analytical conditions given in Annex B are shown in Annex D.

According to the content of the analyte in the specimen, select the mixed standard working solution (5.6) with similar response values for analysis. Take the peak area of the target compound as the ordinate, the concentration of the target compound as the abscissa, to draw a standard working curve. Perform quantitative calculation according to the external standard method. The response values of the analyte in the mixed standard working solution (5.6) and the test solution (7.1) shall be within the linear response range of the instrument. If the content exceeds the standard curve range, use methanol to dilute it to an appropriate concentration and analyze.

7.3 Blank test

In the case of no specimen, follow steps 7.1~7.2.

8 Result calculation and expression

Calculate the content of each isothiazolone in the textile according to formula (1).

Round the calculation result to one decimal place. The test results are expressed in terms of the content of each isothiazolone.

Where, Xi - The content of isothiazolone i in the specimen, in milligrams per kilogram (mg/kg);

Ci - The mass concentration of isothiazolone i in the specimen solution read from the standard working curve, in milligrams per liter (mg/L);

C0 - The mass concentration of isothiazolone i in the blank solution read from the standard working curve, in milligrams per liter (mg/L);

V - The final volume of the specimen solution, in milliliters (mL); m - The mass of the specimen, in grams (g); f - The dilution factor.

9 Limit of quantitation

The limit of quantification for the detection of 7 isothiazolones by HPLC-MS/MS is 0.1mg/kg. The limit of quantification for the detection of 7 isothiazolone compounds by HPLC-DAD is 1.0mg/kg.

10 Precision

At a 95% confidence level, in the same laboratory, by the same operator using the same equipment, according to the same test method, test the same test object independently of each other in a short period of time. The absolute difference between the two test results obtained shall not be greater than 10% of the arithmetic mean of the two measured values.

11 Test report

The test report shall at least give the following:

a) Number of this document;

b) Sample source and description;

c) Instruments and methods used;

d) Test results;

e) Any details that deviate from this document;

f) Test date. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 41559-2022

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 41559-2022