GB/T 41531-2022Textiles—Determination of phenol and bisphenol A (English PDF)
纺织品 苯酚和双酚A的测定
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 41531-2022 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
July 11, 2022
Implementation date
February 1, 2023
Scope
GB/T 41531-2022 is the English-translated version of 纺织品 苯酚和双酚A的测定.
GB/T 41531-2022 describes a high performance liquid chromatography method for determining phenol and bisphenol A in textiles.
The specimen is extracted ultrasonically with methanol, the extract is filtered through a membrane and the filtrate is measured on a liquid chromatograph fitted with a fluorescence detector or a diode array detector, with quantification by the external standard method.
The document covers the reagents and apparatus, the preparation and extraction of specimens, the standard working curve, the qualitative and quantitative analysis, the calculation of results and the test report.
With fluorescence detection the quantitative limit is 1.0 mg/kg for phenol and 2.0 mg/kg for bisphenol A; with diode array detection it is 10.0 mg/kg for both. It applies to all types of textile products, cites GB/T 6682, was issued on 11 July 2022 and has applied since 1 February 2023.
Found what you need?
Document preview — GB/T 41531-2022
National Standard of the People's Republic of China
- ICS
- 59.080.01
- Classification
- W 04
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative References4
- 3 Terms and Definitions4
- 4 Principles4
- 5 Reagents5
- 6 Apparatus5
- 7 Analysis Procedures6
- 8 Calculation and Representation of Result6
- 9 Quantitative Limit of Method7
- 10 Precision7
- 11 Test Report7
- Appendix A (Informative) Analysis of Liquid Chromatography of Phenol and Bisphenol A8
1 Scope
This Document describes a method for the determination of phenol and bisphenol A in textiles using high performance liquid chromatography.
This Document applies to all types of textile products.
2 Normative References
The provisions in following documents become the essential provisions of this Document through reference in this Document. For the dated documents, only the versions with the dates indicated are applicable to this Document; for the undated documents, only the latest version (including all the amendments) is applicable to this Document.
GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods
3 Terms and Definitions
For the purposes of this Document, no terms and definitions apply.
4 Principles
The specimen is ultrasonically extracted with methanol; and the extracting solution is filtered through a filter membrane; and then the specimen is determined by a high-performance liquid chromatograph equipped with a fluorescence detector (HPLC/FLD) or a high-performance liquid chromatograph equipped with a diode array detector (HPLC/DAD); then conduct the quantification by external standard method.
6 Apparatus
6.4 Glass extraction bottle: with a capacity of 40mL and a screw cap.
6.5 Polytetrafluoroethylene filter membrane: The pore size is 0.45µm.
7 Analysis Procedures
7.1 Preparation and extraction of specimens
Take a representative specimen; cut it to less than 5mm×5mm; and mix well. Take 1g from the mixed sample, accurate to 0.01g; put the specimen in the glass extraction bottle (6.4); add 30mL of methanol (5.2) into the glass extraction bottle (6.4); screw the cap tightly. Put the glass extraction bottle (6.4) in an ultrasonic cleaner (6.2); extract at 35°C for (40±2) min; then cool to room temperature; and filter the extracting solution through a polytetrafluoroethylene filter membrane (6.5) as a sample solution for analysis by the instrument.
7.2 Standard working curve
Pipette the mixed standard working solution (5.6); and measure it with reference to the instrument analysis conditions given in A.1 of Appendix A. Take the mass concentration of phenol or bisphenol A as the abscissa, and the corresponding chromatographic peak area as the ordinate, draw the working curve.
7.3 Qualitative and quantitative analysis
Qualitative analysis is carried out by comparing the retention time and spectrum of the measured substance with the standard substance in the chromatogram; and the external standard method is used for quantification. See A.1 for instrument analysis conditions. When the analysis conditions of A.1 are used, the liquid chromatograms of phenol and bisphenol A are shown in Figures A.1 and A.2.
8 Calculation and Representation of Result
Calculate the content of phenol and bisphenol A according to the formula (1), respectively, and the calculation results are accurate to one digit after the decimal point. The test results are represented by the content of phenol and bisphenol A, respectively.
Where:
X - the content of phenol and bisphenol A in the specimen, in mg/kg;
cs - mass concentration of phenol and bisphenol A in the sample solution obtained through the standard working curve, in mg/L;
V - extracting solution volume of specimen, in mL;
f - dilution factor;
m - mass of specimen, in g.
9 Quantitative Limit of Method
9.1 The quantitative limit of HPLC/FLD phenol is 1.0mg/kg; and the quantitative limit of bisphenol A is 2.0mg/kg.
9.2 The quantitative limit of HPLC/DAD phenol is 10.0mg/kg; and the quantitative limit of bisphenol A is 10.0mg/kg.
10 Precision
At the level of confidence at 95%, at the same laboratory, the same operator uses the same device, according to the same measurement method, and independently testing the same measured objects in a short time. The obtained absolution difference of the two independent test results shall be no more than 10% of the arithmetic mean.
11 Test Report
The test report should be given at least the following content:
a) Use this Document;
b) Sample source and description;
c) Types of used detectors;
d) Test results;
e) Any details that deviate from this Document;
f) Test date. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 41531-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-1992 — Water for analytical laboratory use--Specification and test methods
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 41531-2022
$155.00