GB/T 41439-2022Paper, board and pulps - Determination of pH of salted water extracts (English PDF)
This is a limited preview
Buy now to download the full PDF
Need quotation for your management?
Get a formal quotation for GB/T 41439-2022 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
April 15, 2022
Implementation date
November 1, 2022
Scope
GB/T 41439-2022 (Paper, board and pulps - Determination of pH of salted water extracts) is available as an English-translated PDF.
GB/T 41439-2022 — This document describes a method for the determination of pH of salted water extracts of paper, board and pulp. This document applies to paper, board and pulps.
Found what you need?
Document preview — GB/T 41439-2022
National Standard of the People's Republic of China
Issued by: SAMR; SAC
Contents
- Foreword3
- 1 Scope5
- 2 Normative references5
- 3 Terms and definitions5
- 4 Principle5
- 5 Reagents6
- 6 Instruments and equipment6
- 7 Sampling and preparation of sample6
- 8 Test procedures7
- 9 Result calculation8
- 10 Precision8
- 11 Test report9
- Appendix A (Informative) Preparation of standard buffer solutions10
1 Scope
This document describes a method for the determination of pH of salted water extracts of paper, board and pulp.
This document applies to paper, board and pulps.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the version corresponding to that date is applicable to this document; for undated references, the latest version (including all amendments) is applicable to this document.
GB/T 450, Paper and board - Sampling for testing and identification of machine and cross direction, wire side and felt side (GB/T 450-2008, ISO 186:2002, MOD)
GB/T 740, Pulps - Sampling for testing (GB/T 740-2003, ISO 7213:1981, IDT)
3 Terms and definitions
The following terms and definitions are applicable to this document.
3.1 salted water Weak potassium chloride (KCl) solution, whose concentration is 0.100 mol/L.
4 Principle
The sample is soaked in salted water (0.100 mol/L KCl) at 20 °C ~ 25 °C or 90 °C for
1 h. After the suspension is filtered, the pH is measured at a temperature of 20 °C ~ 25 °C.
8 Test procedures
8.1 Soaking in salted water
8.1.1 Perform two tests in parallel.
8.1.2 Air-dry the test pieces in the laboratory atmosphere until they reach moisture equilibrium.
8.1.3 Weigh 2.0 g ~ 2.2 g of the air-dried test pieces into a flask (see 6.2); add 100 mL of salted water (5.3) at a temperature of 20 °C ~ 25 °C. Make sure that all the test pieces are soaked. Cover the flask and let it stand for 1 h; shake the flask (see 6.2) at least once during the standing time. Filter the suspension through a fritted glass filter (see 6.2);
measure the pH of the filtrate. If it is necessary to soak the test pieces in salted water (5.3) at 90 °C, weigh 2.0 g ~ 2.2 g of the air-dried sample into the flask (see 6.2), and add 100 mL of salted water (5.3) at a temperature of 90 °C +/- 5 °C. Then, put the flask (see 6.2) into the thermostat bath (6.3) or on the heating plate (6.3); keep the temperature at 90 °C +/- 5 °C; soak for 1 h; shake the flask (see 6.2) at least once during this period. Cool the suspension in the flask (see 6.2) after the soaking is over; filter the suspension through a fritted glass filter (see 6.2); measure the pH of the filtrate.
8.2 Calibration of the PH meter
8.2.1 Calibrate the pH-meter and the pH-electrodes according to the manufacturer’s instructions. Or proceed according to 8.2.2.
8.2.2 Rinse the electrodes with distilled or deionized water (5.1) and drain. Do not wipe the electrodes. Use two standard buffer solutions (5.2) with different pH values to calibrate the pH-meter at a temperature of 20 °C ~ 25 °C, so that the pH value of the measured extract is between the pH values of the two standard buffer solutions (5.2). If the pH meter does not display the correct pH values for the two standard buffer solutions (5.2), consult the instrument manufacturer's manual.
8.2.3 When not in use, store the electrodes according to the instrument manufacturer's manual.
8.3 Determination of pH After calibrating the pH meter according to the procedure in 8.2, rinse the electrode several times with distilled or deionized water (5.1) and once with a small amount of filtered suspension (i.e., the extract). Under the condition of 20 °C ~ 25 °C, measure and record the pH value of the extract twice in parallel.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 450Paper and board -- Sampling for testing and identification of machine and cross direction, wire side and felt side
- GB/T 450-2008Paper and board -- Sampling for testing and identification of machine and cross direction, wire side and felt side
- GB/T 740Pulps -- Sampling for testing
- GB/T 740-2003Pulps -- Sampling for testing
ISO 186 · ISO 7213
How to Download GB/T 41439-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 450-2008 — Paper and board -- Sampling for testing and identification of machine and cross direction, wire side and felt side
GB/T 740-2003 — Pulps -- Sampling for testing
GB/T 7251.4-2026 — Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)
Secure payment via Stripe
Payments accepted
GB/T 41439-2022
$150.00