GB/T 4130.2-2024Acoustics - Calibration of hydrophones - Part 2: Procedures for low frequency pressure calibration (English PDF)

声学 水听器校准 第2部分:低频声压场校准方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (35 pages)

Need quotation for your management?

Get a formal quotation for GB/T 4130.2-2024 in 30 minutes.

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

December 31, 2024

Implementation date

July 1, 2025

Scope

GB/T 4130.2-2024 is the English-translated version of 声学 水听器校准 第2部分:低频声压场校准方法.

GB/T 4130.2-2024 — This document specifies the method for calibrating the low-frequency sound pressure field of a hydrophone in the frequency range of 0.01 Hz to several kilohertz.

The calibrated frequency range depends on the depending on the calibration method used.

Found what you need?

Document preview — GB/T 4130.2-2024

National Standard of the People's Republic of China

ICS
17.140
Classification
A 59
Replacing
GB/T 4130-2017

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Symbols
  • 5 Calibration Step
  • 5.1 Principle
  • 5.2 Sound field limitation
  • 5.3 Calibration scheme
  • 5.4 Results Report
  • 5.5 Recalibration cycle
  • 5.6 Temperature and pressure considerations for calibration
  • 5.7 Transducer Preparation
  • 6 Electrical Measurements
  • 6.1 Signal Type
  • 6.2 Grounding
  • 6.3 Hydrophone output voltage measurement
  • 6.3.1 General
  • 6.3.2 Electrical load of measuring instruments
  • 6.3.3 Electrical load of extension cables
  • 6.3.4 Crosstalk and acoustic interference
  • 6.3.5 Built-in preamplifier
  • 6.4 Transmitter Current Measurement
  • 7 Hydrostatic excitation calibration
  • 7.1 Overview
  • 7.2 Principle
  • 7.2.1 Determination of alternating pressure
  • 7.2.2 Determination of correction factors
  • 7.2.3 Determination of equivalent height
  • 7.2.4 Calculation of hydrophone sound pressure sensitivity
  • 7.3 Design of vibration systems
  • 7.4 Hydrostatic Excitation Alternative
  • 7.5 Measurement uncertainty
  • 8 Piezoelectric compensation calibration
  • 8.1 Overview
  • 8.2 Principle
  • 8.2.1 Determination of sound pressure
  • 8.2.2 Determination of characteristic constants
  • 8.2.3 Calculation of hydrophone sound pressure sensitivity
  • 8.3 Design of the calibration chamber
  • 8.3.1 Overview
  • 8.3.2 Low frequency cavity
  • 8.3.3 High frequency cavity
  • 8.4 Implementation limitations of piezoelectric compensation
  • 8.5 Comparative calibration method
  • 8.6 Measurement uncertainty
  • 9 Acoustic Coupler Cavity Reciprocity Calibration
  • 9.1 Overview
  • 9.2 Principle
  • 9.2.1 Reciprocity Principle of Acoustic Coupled Cavity
  • 9.2.2 Reciprocity calibration steps
  • 9.2.3 Calculation of transfer impedance
  • 9.2.4 Determination of Tone Compliance
  • 9.3 Limitations of the Reciprocity Method for Acoustically Coupled Cavities
  • 9.3.1 Frequency Limitation
  • 9.3.2 Limitations of hydrophones
  • 9.4 Measurement
  • 9.4.1 General
  • 9.4.2 Impact of interference
  • 9.4.3 Reciprocity Verification
  • 9.4.4 Verification of Linearity
  • 9.5 Measurement uncertainty
  • 10 Pistonphone Calibration
  • 10.1 Overview
  • 10.2 Principle
  • 10.2.1 Determination of sound pressure
  • 10.2.2 Determination of medium compliance
  • 10.2.3 Calculation of hydrophone sound pressure sensitivity
  • 10.3 Restrictions
  • 10.4 Comparison Calibration
  • 10.4.1 Comparative calibration using a reference transducer
  • 10.4.2 Comparative calibration using an air-water pistonphone
  • 10.5 Measurement uncertainty
  • 11 Calibration of vibrating liquid column method
  • 11.1 Overview
  • 11.2 Principle
  • 11.2.1 General
  • 11.2.2 Expression of sound pressure
  • 11.2.3 Determination of sensitivity
  • 11.3 Measurement conditions
  • 11.3.1 Mechanical conditions
  • 11.3.2 Acoustic conditions
  • 11.4 Comparative Calibration
  • 11.5 Measurement uncertainty
  • 12 Calibration of static pressure transducer method
  • 12.1 Overview
  • 12.2 Principle
  • 12.2.1 Principles of static pressure calibration
  • 12.2.2 Determination of the sensitivity of the static pressure transducer
  • 12.2.3 Calculation of sound pressure sensitivity
  • 12.3 Limitations
  • 12.4 Measurement uncertainty
  • Appendix A (Informative) Improved Acoustic Coupler Cavity Calibration Method
  • A.1 Overview
  • A.2 Acoustic Coupler Calibration Based on Reference Coupler Cavity
  • A.2.1 Overview
  • A.2.2 Theory
  • A.3 Calibration of acoustic coupling cavity method based on reference coupling cavity and sound source
  • A.3.1 Overview
  • A.3.2 Theory
  • A.4 Calibration of the acoustic coupling cavity method based on a coupling cavity and a known acoustic compliance auxiliary block
  • A.4.1 Overview
  • A.4.2 Theory
  • Appendix B (Informative) Uncertainty Assessment of Hydrophone Low-Frequency Sound Pressure Field Calibration
  • B.1 Overview
  • B.2 Type A uncertainty assessment
  • B.3 Type B uncertainty assessment
  • B.4 Reporting of uncertainty
  • B.5 Common sources of uncertainty
  • Reference

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting.

This document is part 2 of GB/T 4130 "Calibration of acoustic hydrophones". GB/T 4130 has been published in the following parts.

--- Part 2: Low frequency sound pressure field calibration method.

This document replaces GB/T 4130-2017 "Low-frequency calibration method for acoustic hydrophones". Compared with GB/T 4130-2017, except for the structure in addition to adjustments and editorial changes, the main technical changes are as follows.

--- Added calibration steps (see Chapter 5);

--- Added electrical measurements (see Chapter 6);

--- Added the hydrostatic excitation method alternative (see 7.4);

--- Added pistonphone calibration (see Chapter 10);

--- Added static pressure transducer calibration (see Chapter 12);

--- Deleted the determination of hydrophone voltage coupling loss (see Appendix A of the 2017 edition);

--- Incorporate the determination of equivalent height into the hydrostatic excitation method calibration (see 7.2.3, Appendix B of the 2017 edition);

--- Incorporate the measurement method of the characteristic constants of the piezoelectric compensation transducer into the piezoelectric compensation method calibration (see 8.2.2, Appendix C of the 2017 edition).

This document is equivalent to IEC 60565-2:2019 "Hydroacoustics - Hydrophone calibration - Part 2: Low frequency sound pressure field calibration" step".

The following minimal editorial changes were made to this document.

--- In order to coordinate with the existing standards, the name of the standard is changed to "Acoustic hydrophone calibration part 2.low frequency sound pressure field calibration method";

--- Corrected the error in the original IEC text and moved the normative reference ISO/IEC Guide 98-3 from the references to Chapter 2.

Introduction

Hydrophones are used to convert underwater acoustic signals into electrical signals and are the core of sonar, underwater noise measurement systems, marine acoustic instruments and other equipment.

To ensure the accuracy and reliability of their measurement results, they need to be calibrated before use.

GB/T 4130 "Calibration of Acoustic Hydrophones" describes the calibration method of hydrophones, which aims to standardize and guide the calibration of hydrophones.

It consists of parts.

--- Part 1: Free-field calibration method. The purpose is to establish the free-field calibration of hydrophones and transducers in the frequency range of.200 Hz to 1 MHz.

Free-field calibration method.

--- Part 2: Low-frequency sound pressure field calibration method. The purpose is to establish the low-frequency sound pressure field calibration method of hydrophones in the frequency range of 0.01 Hz to several kilohertz.

Calibration method in high-frequency sound pressure field.

To ensure the accuracy of the calibration, the hydrophone to be calibrated should be a "rigid" hydrophone, which is small in size compared to the wavelength of the sound and Insensitive to vibration during calibration.

This document presents the hydrostatic excitation method, piezoelectric compensation method, acoustic coupling cavity reciprocity method, pistonphone method, vibrating liquid column method and hydrostatic transduction method.

The principles, steps and measurement uncertainty of physical calibration methods such as the hydrophone method. One of the above methods can be used to calibrate the hydrophone.

The choice depends on the principle used and the limitations of the sound field and frequency.

Acoustic Hydrophone Calibration Part 2: Low frequency sound pressure field calibration method

1 Scope

This document specifies the method for calibrating the low-frequency sound pressure field of a hydrophone in the frequency range of 0.01 Hz to several kilohertz. The calibrated frequency range depends on the depending on the calibration method used.

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document.

For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to this document.

ISO/IEC Guide 98-3 Uncertainty of measurement Part 3: Guide to the expression of uncertainty in measurement Note. GB/T 27418-2017 Evaluation and expression of measurement uncertainty (ISO/IEC Guide 98-3..2008, MOD) Note. GB/T 2900.86-2009 Electrical terminology - acoustics and electroacoustics (IEC 60050-801:1994, IDT) IEC 60500:2017 Underwater acoustics - Hydrophones - Characteristics of hydrophones in the frequency range of 1 Hz to 500 kHz

3 Terms and definitions

For the purposes of this document, the terms and definitions defined in IEC 60050-801 and IEC 60500:2017 and listed below apply.

ISO and IEC maintain terminology databases used for standardization at the following URLs.

Coupler

A rigid fluid-filled cavity into which a transducer and a hydrophone can be inserted, the maximum dimension of the cavity being less than the wavelength.

NOTE. In this document, the term "small cavity" is used interchangeably with coupled cavity.

[Source. IEC 60565:2006[1], 3.3, modified] 3.2 Diffraction factor the root mean square value of the incident plane wave sound pressure from a given direction received by the hydrophone is equal to the value of the sound pressure at the reference center of the hydrophone after the hydrophone is removed.

The ratio of the free-field sound pressure to the RMS value.

Note. Perform spatial averaging first, then temporal averaging.

[Source. IEC 60500:2017, 3.3, modified]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 35 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 4130.2-2024

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
35 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 4130.2-2024

$645.00