GB/T 40980-2021Determination of reducing sugar in biochemical products—High-performance liquid chromatography with pre-column derivatization (English PDF)
生化制品中还原糖的测定 柱前衍生高效液相色谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 40980-2021 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
November 26, 2021
Implementation date
June 1, 2022
Scope
GB/T 40980-2021 is the English-translated version of 生化制品中还原糖的测定 柱前衍生高效液相色谱法.
GB/T 40980-2021 is the Chinese standard "Determination of reducing sugar in biochemical products - High-performance liquid chromatography with pre-column derivatization".
Its scope clause reads: This document specifies the determination method that uses high-performance liquid chromatography with pre-column derivatization to determine 10 reducing sugars: D- mannose, D-ribose, L-rhamnose, D-galactose, L-arabinose, D-xylose, L-fucose, D- glucose, D-maltose, D-lactose, in biochemical products.
This document is applicable to the determination of mannose, ribose, rhamnose, galactose, arabinose, xylose, fucose, glucose, maltose, lactose content in glycopepsin, human immune globulin for intravenous injection, rabies immunoglobulin, modified Y medium, glucose broth medium, buffer power-nitrate, xylose-gelatin medium and other biochemical products.
Its clauses include terms and definitions; principle; reagents or materials; instruments and equipment; analysis steps; calculation and presentation of analysis result; precision; other.
It was issued by the State Administration for Market Regulation on NOVEMBER 26, 2021 and took effect on JUNE 01, 2022.
Found what you need?
Document preview — GB/T 40980-2021
National Standard of the People's Republic of China
- ICS
- 07.080
- Classification
- A 40
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Terms and definitions4
- 4 Principle4
- 5 Reagents or materials5
- 6 Instruments and equipment6
- 7 Analysis steps6
- 8 Calculation and presentation of analysis result8
- 9 Precision9
- 10 Other9
- Annex A (informative) Liquid chromatogram10
1 Scope
This document specifies the determination method that uses high-performance liquid chromatography with pre-column derivatization to determine 10 reducing sugars: D- mannose, D-ribose, L-rhamnose, D-galactose, L-arabinose, D-xylose, L-fucose, D- glucose, D-maltose, D-lactose, in biochemical products.
This document is applicable to the determination of mannose, ribose, rhamnose, galactose, arabinose, xylose, fucose, glucose, maltose, lactose content in glycopepsin, human immune globulin for intravenous injection, rabies immunoglobulin, modified Y medium, glucose broth medium, buffer power-nitrate, xylose-gelatin medium and other biochemical products.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 6682, Water for analytical laboratory use - Specification and test methods
3 Terms and definitions
There are no terms and definitions that need to be defined in this document.
4 Principle
The reducing sugars in the sample are extracted by boiling water. The extract is reacted with 1-phenyl-3-methyl-5-pyrazolone (PMP) under alkaline conditions to generate sugar derivatives. Separate by liquid chromatography and determine by UV detector.
Determine the nature by chromatographic retention time. Use external standard method for quantification.
5 Reagents or materials
Unless otherwise specified, all reagents used in this method are analytically pure except that the mobile phase is chromatographically pure. The water used in the test is grade one water specified in GB/T 6682.
5.1 Potassium dihydrogen phosphate (KH2PO4).
5.2 Sodium hydroxide (NaOH).
5.3 Potassium ferrocyanide [K4Fe(CN)6·3H2O].
5.4 Zinc acetate [Zn(CH3COO)2·2H2O].
5.5 1-Phenyl-3-methyl-5-pyrazolone (C10H10N2O, PMP).
5.6 Hydrochloric acid (HCl).
5.7 Trichloromethane (CHCl3).
5.8 Methanol (CH3OH).
5.9 Acetonitrile (CH3CN): Chromatographically pure.
5.10 Triethylamine (C6H15N).
5.11 N-hexane (C6H6).
5.13 Zinc acetate solution (220g/L): Weigh 220.0g of zinc acetate. Use water to dilute to 1000mL.
5.14 0.5mol/L 1-phenyl-3-methyl-5-pyrazolone (PMP) derivative solution: Weigh 87.1g of PMP derivatization reagent. Add methanol to dissolve and dilute to 1000mL.
5.15 1.0mol/L NaOH solution: Weigh 40.0g of sodium hydroxide. Add water to dissolve and dilute to 1000mL.
5.16 1.0mol/L HCl solution: Take 83.2mL of concentrated hydrochloric acid. Slowly add into about 800mL of water. After cooling, add water to make up to 1000mL.
5.17 Sugar standard product: D-mannose (CAS:3458-28-4), D-ribose (CAS:50-69-1), L-rhamnose (CAS:10030-85-0), D-galactose (CAS:59-23-4), L-arabinose (CAS: 5328- 37-0), D-xylose (CAS: 31178-70-8), L-fucose (CAS: 2438-80-4), D-glucose (CAS:50- 99-7), D-maltose (CAS:3458-28-4), D-lactose (CAS:63-42-3). The purity is all >=99%. After cooling the sample solution, add 5mL of n-hexane. Vortex for 2min. Centrifuge at 5000r/min for 5min. Discard the n-hexane layer. Pour the aqueous supernatant into a 50mL volumetric flask. Add 10mL of water to the solid residue. Vortex for 2min. Centrifuge at 5000r/min for 3min. Combine the aqueous layer in the above 50mL volumetric flask. Add 5mL of potassium ferrocyanide solution, 5mL of zinc acetate solution. Use water to set volume to constant. Mix well. Centrifuge to get the supernatant. After filtration through a 0.45m filter membrane, it can be used.
5.12 Potassium ferrocyanide solution (106g/L)
Weigh 106.0g of potassium ferrocyanide. Use water to dissolve and dilute to 1000mL.
7 Analysis steps
7.2.2 Preprocessing of liquid samples containing oil and protein
Weigh 5g of sample (accurate to 0.001g) into a 50mL centrifuge tube. Add 20mL of water. Extract in boiling water bath for 15min. Conduct ultrasonic extraction for 10min.
After the sample solution is cooled, add 3mL of potassium ferrocyanide solution and 3mL of zinc acetate solution. Use water to set volume to 40mL. Shake the centrifuge tube well. Centrifuge at 5000r/min for 5min. Take part of the clarified water layer. Add 5mL of n-hexane. Shake or vortex for 2min. Centrifuge at 5000r/min for 5min. Take the clear liquid from the water layer. After filtration through a 0.45µm filter, it can be used.
7.2.3 Preprocessing of liquid samples not containing oil and protein
Weigh 5g of sample (accurate to 0.001g) into a 50mL centrifuge tube. Add water to 40mL. Extract in boiling water bath for 15min. Conduct ultrasonic extraction for 10min.
After the sample solution has cooled, transfer to a 50mL volumetric flask to set volume to constant. Take the clear liquid from the water layer. After filtration through a 0.45µm filter, it can be used.
7.3 Specimen derivation
Pipette 0.4mL of specimen and standard working solution of different concentrations into a 15mL stoppered test tube. Add 0.2mL of 1.0mol/L NaOH solution and 1.0mL of 0.5mol/LPMP derivative solution. React in a constant temperature water bath at 70°C for 60min. Cool to room temperature. Add 0.2mL of 1.0mol/L HCl solution. After shaking, use nitrogen to dry. Add 2mL of distilled water to reconstitute. Add 2mL of chloroform. After fully vortexing, stand or centrifuge. Discard the lower organic layer.
Repeat this three times. Take the upper aqueous phase. After passing through a 0.45µm filter membrane, it is analyzed by liquid chromatography.
7.4 Instrument chromatographic reference conditions
The instrument chromatographic reference conditions are as follows:
a) Chromatographic column: C18 chromatographic column, 250mm×4.6mm, 3.0µm, or a chromatographic column with equivalent performance;
b) Mobile phase: Phase A is an aqueous solution containing 20mmol/LKH2PO4 (adjusted to pH 7.8±0.1 with triethylamine). Phase B is acetonitrile. The gradient […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 40980-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-1992 — Water for analytical laboratory use--Specification and test methods
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 40980-2021
$135.00