GB/T 39696-2020Determination of flowability of fine ceramic powders. Calibrated funnel (English PDF)
精细陶瓷粉末流动性测定 标准漏斗法
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for GB/T 39696-2020 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
December 14, 2020
Implementation date
November 1, 2021
Scope
GB/T 39696-2020 is the English-translated version of 精细陶瓷粉末流动性测定 标准漏斗法.
GB/T 39696-2020 — This standard specifies the principle, device, sample preparation, test procedure, and result measurement of fine ceramic powder using the standard funnel method: Calculation and test report: This standard applies to granulated ceramic powder and non-granulated ceramic powder that can freely flow through the specified aperture:
Found what you need?
Document preview — GB/T 39696-2020
National Standard of the People's Republic of China
- ICS
- 81.040.10
- Classification
- Q 30
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Principle
- 4 devices
Foreword
This standard was drafted in accordance with the rules given in GB/T 1:1-2009:
This standard uses the redrafting method to amend and adopt ISO 14629:2012 "Fine Ceramics (Advanced Ceramics, Advanced Technical Ceramics) Ceramic Powder
Determination of terminal fluidity:"
Compared with ISO 14629:2012, this standard has many structural adjustments: Appendix A lists the differences between this standard and ISO 14629:2012:
A list of chapter number comparisons:
The technical differences between this standard and ISO 14629:2012 and the reasons are as follows:
--- Regarding normative reference documents, this standard has made adjustments with technical differences to adapt to my country's technical conditions and adjustments:
The situation is reflected in Chapter 2 "Normative Reference Documents", and the specific adjustments are as follows:
* Deleted ISO 80000-1, ISO /IEC 17025;
* Replace ISO 565 (see 4:4) with GB/T 6005 modified to adopt international standards:
This standard also made the following editorial changes:
---The name of the standard was revised to "Standard Funnel Method for the Determination of Flowability of Fine Ceramic Powder":
This standard was proposed by the China Building Materials Federation:
This standard is under the jurisdiction of the National Industrial Ceramics Standardization Technical Committee (SAC/TC194):
Drafting organizations of this standard: Shandong Industrial Ceramics Research and Design Institute Co:, Ltd:, China Building Materials Inspection and Certification Group Zibo Co:, Ltd:, Hefei
Gutai Automation Co:, Ltd:, Hunan Yangdong Electric Porcelain Electric Co:, Ltd:, Sinoma Jiangxi Electric Porcelain Electric Co:, Ltd:
1 Scope
This standard specifies the principle, device, sample preparation, test procedure, and result measurement of fine ceramic powder using the standard funnel method:
Calculation and test report:
This standard applies to granulated ceramic powder and non-granulated ceramic powder that can freely flow through the specified aperture:
2 Normative references
The following documents are indispensable for the application of this document: For dated reference documents, only the dated version applies to this document.
Pieces: For undated references, the latest version (including all amendments) applies to this document:
GB/T 6005 Test sieve The basic size of woven wire mesh, perforated plate and electroformed sheet screen hole (GB/T 6005-
2008, ISO 565:1990, MOD)
3 Principle
Measure the time required for 50:0g of ceramic powder to flow through the standard-sized funnel hole, and divide the outflow time by the mass of the outflow powder to obtain a single
The quality of the powder flowing out of the funnel within the set time is used to characterize the fluidity of the powder:
4 devices
4:1 Standard funnel
Made of non-magnetic, corrosion-resistant, material with certain strength and hardness (such as 304 stainless steel), the structure and dimensions are shown in Figure 1:
As shown, the apertures are 2:5mm and 5:0mm respectively:
4:2 Collector
The structure and dimensions of the cylindrical stainless steel barrel are shown in Figure 2:
4:3 Stand and base
The test stand and base should be level and free of vibration: The structure is shown in Figure 3: The standard funnel hole should be approximately above the collector:
At 50mm:
4:4 Test sieve
Meet the requirements of GB/T 6005, a metal sieve with an aperture of 0:71mm:
4:5 Balance
The accuracy is better than 0:1g: When weighing fluffy powder materials, choose a balance with an accuracy of 0:01g:
4:6 Stopwatch
The accuracy is +/-0:1s:
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
Referenced standards
How to Download GB/T 39696-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6005-1997 — Test sieves--Metal wire cloth, perforated metal plate and electroformed sheet--Nominal sizes of opening
GB/T 6005-2008 — Test sieves -- Metal wire cloth, perforated metal plate and electroformed sheet -- Nominal sizes of openings
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
Secure payment via Stripe
Payments accepted
GB/T 39696-2020
$105.00