GB/T 3884.2-2012Methods for chemical analysis of copper concentrates - Part 2: Determination of gold and silver contents - Flame atomic absorption spectrometric method and fire assay method (English PDF)
铜精矿化学分析方法 第2部分:金和银量的测定 火焰原子吸收光谱法和火试金法
This is a limited preview
Buy now to download the full PDF (14 pages)
Need quotation for your management?
Get a formal quotation for GB/T 3884.2-2012 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Recommended
Issue date
August 29, 2025
Implementation date
March 1, 2026
Scope
GB/T 3884.2-2012 is the English-translated version of 铜精矿化学分析方法 第2部分:金和银量的测定 火焰原子吸收光谱法和火试金法.
GB/T 3884.2-2012 is the Chinese standard "Methods for chemical analysis of copper concentrates - Part 2: Determination of gold and silver contents - Flame atomic absorption spectrometric method and fire assay method".
Its scope clause reads: This document describes the methods for determining the gold and silver content in copper concentrate and copper slag concentrate, using flame atomic absorption spectrometry and fire assay.
Methods 1 and 2 of this document are applicable to the determination of gold and silver content in copper concentrate and copper slag concentrate. Method 1 has a determination range of silver.
10.0 g/t ~ 500.0 g/t; Method 2 has a determination range of gold. 0.50 g/t ~ 56.00 g/t, silver. 50.0 g/t ~ 2500.0 g/t. Method 3 is applicable to the determination of gold and silver content in copper sulfide concentrate with a copper content of 15% ~ 60%, with a determination range of gold.
0.50 g/t ~ 300.00 g/t, silver. 25.0 g/t ~ 1500.0 g/t. Its clauses include terms and definitions; method 1 -- flame atomic absorption spectrometry; method 2 -- fire assay.
It was issued by the State Administration for Market Regulation on 2025-08-29 and took effect on 2026-03-01.
Found what you need?
Document preview — GB/T 3884.2-2012
National Standard of the People's Republic of China
- ICS
- 77.120.30
Issued by: State Administration for Market Regulation
Contents
- Foreword...3
- Introduction...8
- 1 Scope...10
- 2 Normative references...10
- 3 Terms and definitions...11
- 4 Method 1 -- Flame atomic absorption spectrometry...11
- 5 Method 2 -- Fire assay...14
1 Scope
This document describes the methods for determining the gold and silver content in copper concentrate and copper slag concentrate, using flame atomic absorption spectrometry and fire assay.
Methods 1 and 2 of this document are applicable to the determination of gold and silver content in copper concentrate and copper slag concentrate. Method 1 has a determination range of silver. 10.0 g/t ~ 500.0 g/t; Method 2 has a determination range of gold. 0.50 g/t ~ 56.00 g/t, silver. 50.0 g/t ~ 2500.0 g/t. Method 3 is applicable to the determination of gold and silver content in copper sulfide concentrate with a copper content of 15% ~ 60%, with a determination range of gold. 0.50 g/t ~ 300.00 g/t, silver.
25.0 g/t ~ 1500.0 g/t.
2 Normative references
The following documents, through normative references in this document, constitute essential provisions of this document. For dated references, only the edition cited applies; for undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 385 Laboratory glassware - Burettes
ISO 648 Laboratory glassware - Single-volume pipettes
ISO 1042 Laboratory glassware - One-mark volumetric flasks
ISO 3696 Water for analytical laboratory use - Specification and test methods
ISO 4787 Laboratory glass and plastic ware - Volumetric instruments - Methods for testing of capacity and for use
ISO 9599 Copper, lead, zinc and nickel sulfide concentrates - Determination of hygroscopic moisture content of the analysis sample - Gravimetric method
3 Terms and definitions
This document does not contain any terms or definitions that require clarification.
4 Method 1 -- Flame atomic absorption spectrometry
4.1 Principle
The sample is dissolved in nitric acid, hydrofluoric acid, perchloric acid, hydrochloric acid. In a dilute hydrochloric acid medium, the absorbance of silver is measured using a flame atomic absorption spectrometer, at a wavelength of 328.1 nm with an air- acetylene flame. The silver content is calculated using the standard curve method.
4.2 Reagents
Unless otherwise specified, only reagents confirmed to be of analytical grade and distilled or deionized water or water of equivalent purity shall be used in the analysis.
4.2.1 Nitric acid (rho = 1.42 g/mL).
4.2.2 Hydrochloric acid (rho = 1.19 g/mL).
4.2.3 Hydrofluoric acid (rho = 1.42 g/mL).
4.2.4 Perchloric acid (rho = 1.67 g/mL).
4.2.5 Silver standard stock solution. Weigh 0.1000 g of silver (wAg >= 99.99%) into a
200 mL beaker; add 20 mL of nitric acid (1 + 1); heat until completely dissolved; cool to room temperature; transfer to a 200 mL amber volumetric flask; dilute to the mark with chloride-free water; mix well. 1 mL of this solution contains 500 µg of silver.
4.2.6 Silver standard solution. Transfer 10.00 mL of the silver standard stock solution
(4.2.5) to a 100 mL volumetric flask; dilute to the mark with hydrochloric acid (1 + 3);
mix well. 1 mL of this solution contains 50 µg of silver.
4.3 Instruments
Flame atomic absorption spectrometer with a silver hollow cathode lamp.
Under optimal instrument operating conditions, any instrument meeting the following specifications may be used.
- Characteristic concentration. In a solution consistent with the matrix of the sample solution, the characteristic concentration of silver shall not exceed 0.018 µg/mL;
- Precision. When measuring absorbance 10 times with the highest concentration standard solution, the standard deviation shall not exceed 1.0% of the average absorbance. When measuring absorbance 10 times with the lowest concentration standard solution (not the "zero" standard solution), the standard deviation shall not exceed 0.5% of the average absorbance of the highest concentration standard solution;
- Linearity of the working curve. Dividing the working curve into 5 equal segments according to concentration, the ratio -- of the absorbance difference in the highest segment to the absorbance difference in the lowest segment -- shall not be less than
0.85.
4.4 Samples
4.4.1 The sample particle size shall not exceed 100 µm.
4.4.2 The sample shall be dried at 100 °C ~ 105 °C for 1 hour, then placed in a desiccator and cooled to room temperature.
4.5 Test procedure
4.5.1 Sample
Weigh 0.5 g of sample (4.4), accurate to 0.0001 g.
4.5.2 Parallel test
Perform two parallel tests and take the average value.
4.5.3 Blank test
Perform a blank test along with the sample.
4.5.4 Determination
4.5.4.1 Place the sample (4.5.1) in a 250 mL PTFE beaker; add a small amount of water to moisten; add 15 mL of nitric acid (4.2.1); heat on a hot plate at low temperature to dissolve; evaporate to a volume of about 10 mL; remove and let cool slightly. Add 5 mL of hydrofluoric acid (4.2.3); continue heating to dissolve while shaking occasionally;
dissolve to a small volume; remove and let cool slightly. Add 5 mL of perchloric acid (4.2.4); cover with a PTFE watch glass; heat to dissolve until there is no black residue at the bottom of the beaker; remove and let cool slightly. Rinse the watch glass and beaker walls with water; add 5 mL of hydrochloric acid (4.2.2); continue heating until the perchloric acid emits white fumes. Evaporate to near dryness; then remove and cool.
4.5.4.2 Add hydrochloric acid (4.2.2) according to Table 1; rinse the watch glass and beaker walls with water; heat to dissolve the salts; remove and cool to room temperature.
Transfer the solution to a volumetric flask of the appropriate volume (the volume of the volumetric flask is the measurement volume in Table 1); dilute with water to the mark;
mix well; let it stand (or filter dry).
Table 1 -- Constant volume and volume for adding hydrochloric acid
4.5.4.3 Using an air-acetylene flame, at the analytical wavelength of silver (328.1 nm), zero the instrument with water and measure the absorbance of the blank solution and the sample solution. Determine the corresponding silver mass concentration from the working curve.
4.5.5 Plotting the working curve
4.5.5.1 Pipette 0 mL, 0.20 mL, 1.00 mL, 2.00 mL, 3.00 mL, 4.00 mL, 5.00 mL of silver standard solution (4.2.6) into a set of 100 mL volumetric flasks (when the mass fraction of silver in the sample is 10.0 g/t ~ 20.0 g/t, add an equal amount of copper and iron matrix solution to the sample solution). Add 10.0 mL of hydrochloric acid (4.2.2); dilute to the mark with water; mix well.
4.5.5.2 Under the same conditions as the sample solution, at the analytical wavelength
of silver (328.1 nm), zero the instrument with water and measure the absorbance of the silver standard solutions. Subtract the absorbance of the "zero" concentration solution from the series of standard solutions. Plot the working curve with the mass concentration of silver as the abscissa and the corresponding absorbance as the ordinate.
4.6 Test data processing
The silver content is expressed as a mass fraction wAg, in g/t, which is calculated according to formula (1).
Where.
rho1 - Mass concentration of silver in the test solution obtained from the working curve, in micrograms per milliliter (µg/mL);
rho0 - Mass concentration of silver in the blank solution obtained from the working curve, in micrograms per milliliter (µg/mL);
V - Total volume of the test solution, in milliliters (mL);
m0 - Mass of the sample, in grams (g).
The calculation result is expressed to one decimal place.
4.7 Precision
4.7.1 Repeatability
Under repeatability conditions, the absolute difference between two independent test results within the average range given in Table 2 does not exceed the repeatability limit (r); the number of cases exceeding the repeatability limit (r) does not exceed 5%. The repeatability limit (r) is obtained using linear interpolation or extrapolation according to Table 2.
Table 2 -- Repeatability limits (r) for Method 1
4.7.2 Reproducibility
The absolute difference between two independent test results, which are obtained under reproducibility conditions, within the average range given in Table 3, shall not exceed the reproducibility limit (R). The cases exceeding the reproducibility limit (R) shall not exceed 5%. The reproducibility limit (R) is obtained using linear interpolation or extrapolation based on the data in Table 3.
Table 3 -- Reproducibility limits (R) of Method 1
5 Method 2 -- Fire assay
5.1 Principle
The sample is prepared and melted at high temperature. The molten lead traps the precious metals in the sample to form lead clasps. Other substances in the sample react with the flux to form fusible slag. The lead clasps are blown away to obtain gold-silver granules. Impurities adhering to the surface of the granules are removed. Gold is separated by nitric acid; the silver content is determined by titration, or the gold content is determined by gravimetric method or flame atomic absorption spectrometry.
5.2 Reagents
Unless otherwise specified, only reagents confirmed to be of analytical grade and distilled water or deionized water or water of equivalent purity are used in the analysis.
5.2.1 Anhydrous sodium carbonate. Industrial grade, powder.
5.2.2 Lead oxide. Industrial grade, powder (wAu < 0.01 g/t; wAg < 0.5 g/t).
5.2.3 Borax. Industrial grade, powder.
5.2.4 Silica. Industrial grade, powder.
5.2.5 Starch. Industrial grade, powder.
5.2.6 Potassium nitrate. Analytical grade.
5.2.7 Sodium chloride. Industrial grade, powder.
5.2.8 Silver (wAg >= 99.99%).
5.2.9 Nitric acid (rho = 1.42 g/mL). Chloride ion free.
5.2.10 Nitric acid (1 + 1). Chloride ion free.
5.2.11 Nitric acid (1 + 7). Chloride ion free.
5.2.12 Mixed acid. 3 parts by volume of hydrochloric acid (rho = 1.19 g/mL) + 1 part by volume of nitric acid (5.2.9), prepare fresh before use.
5.2.13 Ferric ammonium sulfate solution. Take 1 part by volume of saturated ferric
ammonium sulfate solution and add 3 parts by volume of nitric acid (1 + 3); mix well.
5.2.14 Potassium thiocyanate standard titration solution. Prepare and standardize
according to the following steps.
a) Preparation. Weigh 0.5 g of potassium thiocyanate; place it in a 100 mL beaker;
dissolve it in water; transfer it to a 1000 mL volumetric flask; dilute to the mark with water; mix well. Filter after standing for one week; prepare for later use.
b) Standardization. Weigh three portions of silver (10.00 mg ~ 15.00 mg, 5.2.8);
place them separately in porcelain crucibles (5.3.7). Add 10 mL ~ 15 mL of nitric acid (5.2.10); gently heat to dissolve; evaporate to 1 mL ~ 2 mL. Add a small amount of water and 0.5 mL of ferric ammonium sulfate solution (5.2.13); titrate until a light pink color is obtained, which is the endpoint.
Calculate the actual concentration of the potassium thiocyanate standard titration solution using formula (2).
Where.
c - Actual concentration of the potassium thiocyanate standard titration solution, in moles (mol/L);
m1 - Mass of silver, in milligrams (mg);
107.868 - Molar mass of silver, in grams per mole (g/mol), [MAg = 107.868];
V1 - Volume of potassium thiocyanate standard titration solution consumed in titrating silver, in milliliters (mL);
V0 - Volume of potassium thiocyanate standard titration solution consumed in titrating the blank solution, in milliliters (mL).
If the range of the three calibration results is not greater than 4 × 10^-^5 mol/L, take the average of the three calibration results; otherwise, recalibrate.
5.2.15 Gold standard stock solution. Weigh 0.1000 g of gold (wAu >= 99.99%) into a 100 mL beaker; add 10 mL of mixed acid (5.2.12); cover with a watch glass; evaporate to near dryness in a water bath; remove and cool slightly; add 20 mL of hydrochloric acid (1 + 1); rinse the beaker and watch glass with a small amount of water; transfer the solution to a 100 mL volumetric flask; dilute to the mark with water; mix well. 1 mL of this solution contains 1 mg of gold.
5.2.16 Gold standard solution. Transfer 10.00 mL of the gold standard stock solution
(5.2.15) into a 100 mL volumetric flask; add 20 mL of hydrochloric acid (1 + 1); dilute to the mark with water; mix well. 1 mL of this solution contains 100 µg of gold.
5.3 Instruments and equipment
5.3.1 Microbalance. Sensitivity 0.0001 mg.
5.3.2 Assay furnace. Maximum heating temperature 1200 °C.
5.3.3 Refractory clay crucible. Volume approximately 350 mL.
5.3.4 Ash dishes.
5.3.5 Specimen pulverizer.
5.3.6 Porcelain crucible. Volume 30 mL.
5.3.7 Porcelain crucible. Volume 50 mL or 100 mL.
5.3.8 Atomic absorption spectrometer, equipped with a gold hollow cathode lamp.
Under optimal instrument operating conditions, any instrument meeting the following specifications may be used.
- Characteristic concentration. In a solution consistent with the matrix of the measurement solution, the characteristic concentration of gold shall not exceed
0.08 µg/mL;
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.
Referenced standards
Normative references
ISO 385 · ISO 648 · ISO 1042 · ISO 3696 · ISO 4787 · ISO 9599
How to Download GB/T 3884.2-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 3884.1-2025 — Methods for chemical analysis of copper concentrates - Part 1: Determination of copper content - Iodine titration method and electrogravimetric method
GB/T 3884.10-2012 — Methods for chemical analysis of copper concentrates -- Part 10: Determination of Antimony content -- Hydride generation atomic fluorescence spectrometry method
GB/T 3884.11-2005 — Methods for chemical analysis of copper concentrates-Determination of mercury content-Cold atomic absorption spectrometric method
Secure payment via Stripe
Payments accepted
GB/T 3884.2-2012
$640.00