Scope

GB/T 38481-2020 is the English-translated version of 微生物超低频突变测定 双重测序法.

GB/T 38481-2020 is the Chinese standard "Determination of ultralow-frequency mutations for microorganisms - Duplex sequencing". Its scope clause reads: This Standard specifies the method for the determination of ultralow-frequency mutations for microorganisms by duplex sequencing.

This Standard is applicable to the determination of ultralow-frequency mutations in microbial genomes or gene fragments.

Its clauses include terms and definitions; principle; reagents; apparatus and utensil; preparation of the sample; synthesis of linker barcode label; high-throughput sequencing; analysis of the results; calculation and presentation of the results.

It was issued by the State Administration for Market Regulation on NOVEMBER 19, 2020 and took effect on NOVEMBER 19, 2020.

Found what you need?

Document preview — GB/T 38481-2020

National Standard of the People's Republic of China

ICS
07.080
Classification
A 21

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative References4
  • 3 Terms and Definitions4
  • 4 Principle5
  • 5 Reagents5
  • 6 Apparatus and Utensil6
  • 7 Preparation of the Sample6
  • 8 Synthesis of Linker Barcode Label6
  • 9 Connection and Amplification of the Linker Barcode Label and the DNA of the Sample to be Tested7
  • 10 High-throughput Sequencing8
  • 11 Analysis of the Results8
  • 12 Calculation and Presentation of the Results8

1 Scope

This Standard specifies the method for the determination of ultralow-frequency mutations for microorganisms by duplex sequencing.

This Standard is applicable to the determination of ultralow-frequency mutations in microbial genomes or gene fragments.

2 Normative References

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) is applicable to this document.

GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods

3 Terms and Definitions

For the purpose of this document, the following terms and definitions apply.

3.1 Ultralow-frequency mutations

Chemical, physical or biological factors lead to permanent changes of microbial DNA with a frequency of less than 1 x 10^-5.

3.2 Barcode label

Use the nucleotide fragments connected to both sides of the DNA fragment to be tested to mark the DNA of the same amplified family and assist in the confirmation of mutation sites.

3.3 Complementary tag family

All DNA fragments with complementary barcode labels at both ends.

5 Reagents

5.7 DNA analysis kit.

5.8 Tris-ethylenediaminetetraacetic acid (Tris-EDTA) buffer solution, pH 8.0. Prepared by 10mmol/L analytical pure Tris and 0.1mmol/L EDTA, adjust the pH value to 8.0.

6 Apparatus and Utensil

6.5 Electronic balance: the accuracy is 0.01g.

6.1 PCR thermal cycler

6.2 Magnetic separator

6.3 High-throughput sequencer

6.4 Nucleic acid analysis system

7 Preparation of the Sample

7.1 DNA extraction

Use microbial genome or plasmid extraction kit to perform genomic or plasmid DNA extraction operation on the sample to be tested; and finally use 50µL of sterile double-distilled water for DNA elution. The extracted DNA sample is used to detect the concentration and purity of nucleic acid by a nucleic acid quantifier.

7.2 DNA fragmentation and end repair

Use the high-throughput gene sequencing library building kit to fragment the DNA of the sample to be tested to 100bp~1000bp, and repair the end to the Tail-A.

8 Synthesis of Linker Barcode Label

8.1 Annealing

Take 100µL of each of the two linker chain oligonucleotide fragments with a concentration of 100µmol/L for annealing; heat at 95°C for 5min, then cool down naturally, and stand for 1h.

8.2 Extension

The product obtained in 8.1 is mixed with deoxyribonucleoside triphosphate mixture (dNTPs) and Klenow enzyme according to the instructions of the reagents; divide them Use the sorted product as the template and the linker chain amplification primer sequence as the primer; 1 amol DNA sample amount per 200,000 readings was used for PCR amplification. The amplification program is set according to the requirements of the selected high-fidelity DNA polymerase.

10 High-throughput Sequencing

Use a high-throughput sequencing kit to perform high-throughput sequencing on the amplified PCR products; and the number of sequencing bases for each sample to be tested is set to be greater than or equal to 10Gb.

11 Analysis of the Results

Clean the high-throughput sequencing data; and then perform data analysis according to the following procedures:

a) Complementary label classification based on random labels is performed; each family needs to contain two-way complementary sequences. For the complementary tag family size distribution after excluding 1, the maximum peak shall be distributed between 6 and 12.

b) Only when the double-stranded homologous sequence recognizes the mutation at the same site shall it be regarded as the real mutation site.

12 Calculation and Presentation of the Results

12.1 Calculation of the results

The mutation rate is calculated according to Formula (1):

Where: M - mutation rate;

Nm - the number of mutation sites of double-stranded homologous sequence; Nt - the total number of sequenced nucleotides without tags. […]

12.2 Presentation of results

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 38481-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 38481-2020

$85.00