Scope

GB/T 37385-2019 is the English-translated version of 硅中氯离子含量的测定 离子色谱法.

GB/T 37385-2019 is the Chinese standard "Test method for chloride content of silicon - Ion chromatography method". Its scope clause reads: This Standard specifies ion chromatography test method for chloride content of silicon.

This Standard is applicable to the determination of chloride content of rod silicon, block silicon, granular silicon, and flake silicon. The determination range is from 1.0µg/g to the maximum solid solubility of chloride in silicon.

Its clauses include method principle; interference factors; reagents and materials; instruments and devices; specimen; test steps; test data processing; precision; quality assurance and control; test report.

It was issued by the State Administration for Market Regulation on MARCH 25, 2019 and took effect on FEBRUARY 01, 2020.

Found what you need?

Document preview — GB/T 37385-2019

National Standard of the People's Republic of China

ICS
77.040
Classification
H 17

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Method principle4
  • 4 Interference factors4
  • 5 Reagents and materials5
  • 6 Instruments and devices5
  • 7 Specimen5
  • 8 Test steps6
  • 9 Test data processing7
  • 10 Precision7
  • 11 Quality assurance and control8
  • 12 Test report9
  • Annex A (informative) Working reference conditions of ion chromatograph10

1 Scope

This Standard specifies ion chromatography test method for chloride content of silicon.

This Standard is applicable to the determination of chloride content of rod silicon, block silicon, granular silicon, and flake silicon. The determination range is from 1.0µg/g to the maximum solid solubility of chloride in silicon.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB/T 6679, General rules for sampling solid chemical products

GB/T 6682-2008, Water for analytical laboratory use - Specification and test methods

3 Method principle

Place the sample in a high-temperature tube type furnace to heat. After the sample is melt, chlorine shall be released in the form of chloride. Use a bubble absorption bottle that is filled with water to absorb. Then use ion chromatograph to determine the chloride content in the absorption solution.

4 Interference factors

4.1 The material purity of the sample tube and the sample container of the high-temperature tube type furnace shall affect the test results. If the purity is not enough, the impurities in the sample tube and the sample container shall evaporate at a high temperature.

4.2 The sample tube and the sample container of the high-temperature tube prepared absorption bottles connected in series (8.3) to the exhaust port of the high-temperature tube type furnace. Adjust the flow of argon to 200mL/min~300mL/min. Argon enters absorption bottle through the high-temperature tube type furnace.

8 Test steps

8.5.2 Heat test portion from room temperature to 1500°C and remain at 1500°C for 20min. Then cool to room temperature. During this process, chlorine in the sample is released in the form of chloride and absorbed by water in the absorption bottle.

8.5.3 Use ion chromatograph to determine the chloride content of the solution in the absorption bottle. When the chloride content in the sample is below or exceeds the standard curve drawing range, it shall adjust the sample quantity according to Table 1 to re-analyze. Refer to Annex A for the working conditions of ion chromatograph.

9 Test data processing

The chloride content w in test portion is calculated according to formula (1):

Where, w - Chloride content in test portion, in micrograms per gram (µg/g); c1 - Content of chloride in the first absorption bottle, in micrograms per milliliter (µg/mL); c2 - Content of chloride in the second absorption bottle, in micrograms per milliliter (µg/mL); c0 - Sum of blank chloride in two absorption bottles, in micrograms per milliliter (µg/mL);

V - Total volume of water in two absorption bottles, in milliliters (mL); m - Mass of test portion, in grams (g).

The calculation result is expressed to one digit after the decimal point.

10 Precision

10.1 For the measured values of two independent test results obtained under […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 37385-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 37385-2019

$150.00