Valid

GB/T 37158-2018Non-destructive testing—Test method for measuring the maximum detectable steel thickness by industrial computed tomography(CT) (English PDF)

无损检测 工业计算机层析成像(CT)检测最大可检测钢厚度测试方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 37158-2018 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 28, 2018

Implementation date

July 1, 2019

Scope

GB/T 37158-2018 is the English-translated version of 无损检测 工业计算机层析成像(CT)检测最大可检测钢厚度测试方法.

GB/T 37158-2018 sets out how to measure the maximum detectable steel thickness of an industrial computed tomography (CT) system. It applies to industrial CT systems with a ray energy of 225 keV and above, and uses the phantom described in GB/T 37122, made of round steel discs of different outer diameters.

The standard gives the testing requirements and steps, and defines the result: under specified spatial resolution, the outer diameter of the largest disc that still meets R of at least 10% and CNR of at least 3 is taken as the maximum detectable steel thickness.

It also lists what the testing record, the image data file and the test report must contain, and an annex recommends disc diameters. The standard was issued on 28 December 2018 and has applied since 1 July 2019.

Found what you need?

Document preview — GB/T 37158-2018

National Standard of the People's Republic of China

ICS
19.100
Classification
J 04

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Terms and definitions4
  • 4 Testing requirements and steps5
  • 5 Result evaluation6
  • 6 Testing record and report9
  • Annex A (informative) Recommended outer diameters of phantom round disc10

1 Scope

This Standard specifies the test method for measuring the maximum detectable steel thickness by industrial computed tomography (CT).

This Standard is applicable to the test for measuring the maximum detectable steel thickness indicator of industrial CT system of which the radian energy is 225 keV and above.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB/T 12604.2, Non-destructive testing - Terminology - Terms used in radiographic testing

GB/T 29069, Non-destructive testing - Test method for measurement of industrial computed tomography (CT) system performance

GB/T 34365, Non-destructive testing - Terminology - Terms used in industrial computed tomography testing

GB/T 37122, Non-destructive testing - Phantom of maximum detectable steel thickness for industrial computed tomography (CT)

3 Terms and definitions

For the purposes of this document, the terms and definitions defined in GB/T 12604.2 and GB/T 34365 as well as the following apply.

3.1 The maximum detectable steel thickness

For a specific CT system, under certain conditions such as scanning and […]

5 Result evaluation

5.3 Guideline

Under specified spatial resolution conditions, when R=10% and CNR=3, the outer diameter size of round disc of tested phantom is defined as the maximum detectable steel thickness. This thickness value usually requires multiple testing of fitting curves. To simplify testing, it usually regards the outer diameter size of round disc of testable maximum phantom as the maximum detectable steel thickness under specified spatial resolution conditions, when R>=10% and CNR>=3.

6 Testing record and report

6.1 Testing record

6.1.1 Testing record usually shall contain detailed records such as standard test piece name, test purpose, test equipment, ray source parameters, scanning mode, slice thickness, slice position, scanning time, field of view diameter, image matrix, reconstruction parameters, image description, evaluation criteria, tester, reviewer, test date.

6.1.2 Image data file shall generally include image number, standard test piece name, test purpose, test equipment, ray source parameters, scanning mode, slice thickness, slice position, scanning time, field of view diameter, image matrix, reconstruction parameters, etc.

6.2 Testing report

Testing report shall usually contain standard test piece name, test purpose, test equipment, test method, slice thickness, slice position, image matrix, test image, evaluation standard, evaluation result, tester, reviewer, approver, test date, report date. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 37158-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 37158-2018