GB/T 36940-2018Textiles—Determination of certain benzotriazole compounds (English PDF)
纺织品 苯并三唑类物质的测定
This is a limited preview
Buy now to download the full PDF (16 pages)
Need quotation for your management?
Get a formal quotation for GB/T 36940-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 28, 2018
Implementation date
July 1, 2019
Scope
GB/T 36940-2018 is the English-translated version of 纺织品 苯并三唑类物质的测定.
GB/T 36940-2018 is the Chinese national test method for measuring certain benzotriazole compounds in textile products, with the substances covered listed in Annex A. The sample is cut into small pieces and extracted ultrasonically at 60 °C with n-hexane-saturated acetonitrile; the filtered extract is then analysed either by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) or by liquid chromatography with a diode array detector (HPLC-DAD), and quantified by the external standard method.
The standard sets out the reagents, apparatus, test procedure, calculation and expression of results, the lower limits of determination of the two methods and their precision, and what the test report must contain.
It applies to all types of textile products and is used by testing laboratories. It was issued on 28 December 2018 and has applied since 1 July 2019.
Found what you need?
Document preview — GB/T 36940-2018
National Standard of the People's Republic of China
- ICS
- 59.080.01
- Classification
- W 04
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Principle4
- 4 Reagents and materials5
- 5 Apparatus and equipment6
- 6 Test procedures6
- 7 Calculation and expression of results9
- 8 Lower limit of determination and precision of the methods10
- 9 Test report10
- Appendix A (Normative) Information on reference materials12
- Appendix B (Informative) Mass spectrometry reference conditions13
- Appendix C (Informative) Multi-reaction monitoring diagrams (MRM) of benzotriazole compound reference materials14
- Appendix D (Informative) HPLC-DAD chromatograms and UV spectrograms of benzotriazole compound reference materials16
1 Scope
This Standard specifies the test method for determination of certain benzotriazole compounds (see Appendix A) in textile products using high performance liquid chromatography-tandem mass spectrometer (HPLC- MS/MS) or high performance liquid chromatograph-diode array detector (HPLC-DAD). This Standard applies to all types of textile products.
2 Normative references
The following documents are indispensable for the application of this document.
For the dated references, only the editions with the dates indicated are applicable to this document. For the undated references, the latest edition (including all the amendments) are applicable to this document.
GB/T 6682 Water for analytical laboratory use - Specification and test methods
3 Principle
USE n-hexane-saturated acetonitrile-ultrasound to extract certain benzotriazole compounds in textiles. After the extract is filtered through a filter membrane, use high performance liquid chromatography-tandem mass spectrometer (HPLC-MS/MS) or high performance liquid chromatograph-diode array detector (HPLC-DAD) to determine and confirm; use external standard method to quantify.
5 Apparatus and equipment
5.1 Analytical balance: The division value is 0.01 g.
5.2 Reactor: sealed with a plug. It is about 25 mL and made of hard glass.
5.3 Ultrasonic generator: The working frequency is 40 kHz. Temperature is controllable.
5.4 Volumetric flask: 25 mL.
5.5 Disposable syringe: 1 mL.
5.6 Organic filter membrane: 0.22 µm; nylon or other organic phase.
5.7 High performance liquid chromatography-tandem mass spectrometer (HPLC-MS/MS).
5.8 High performance liquid chromatograph-diode array detector (HPLC-DAD).
6 Test procedures
6.1 Extraction and purification
TAKE a representative sample; CUT it to less than 5 mm×5 mm and mix well.
WEIGH 1.0 g (accurate to 0.01 g); PUT it in the reactor (5.2); ADD 15 mL of n-hexane saturated acetonitrile (4.9); EXTRACT in a 60 °C ultrasonic generator (5.3) for 15 min. FILTER the extract; USE 10 mL of n-hexane-saturated acetonitrile (4.9) to ultrasonically extract the residue for 15 min. Combine the filtrates and collect in a 25 mL volumetric flask (5.4); COOL to room temperature and dilute to the mark. The sample solution is filtered through a 0.22 µm organic filter membrane (5.6). TAKE the filtrate as a test solution for machine analysis.
6.2 HPLC-MS/MS method
6.2.1 HPLC-MS/MS analysis conditions
Because the test results depend on the apparatus used, it is not possible to give general parameters for chromatography/mass spectrometry. The following parameters have proven suitable for testing:
a) Chromatographic column: Eclipse Plus C18 column, 3.5 µm, 2.1 mm×50 mm or an equivalent column;
b) Mobile phase A: methanol (4.1);
7 Calculation and expression of results
7.2 Expression of results
The test results are expressed by the detection results of benzotriazole compounds respectively. The results are retained to one decimal place. When below the lower limit of determination, the test result is "not-detected".
8 Lower limit of determination and precision of the methods
8.1 Lower limit of determination
The lower limit of determination of benzotriazole compounds by HPLC-MS/MS method is 1 mg/kg. The lower limit of determination of benzotriazole compounds by HPLC-DAD method is 20 mg/kg.
8.2 Precision
In the same laboratory, using the same equipment by the same operator, according to the same test method, and within a short period of time, the relative standard deviation of the two test results obtained from tests performed independently on the same measured object is not more than 10%, on the premise of no more than 5% in cases greater than 10%.
9 Test report
The test report shall give at least the following:
a) The number of this Standard;
b) A detailed description of the test sample;
c) Description of apparatus method;
d) Test results;
e) Any differences from the prescribed procedures; […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 36940-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-1992 — Water for analytical laboratory use--Specification and test methods
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 36940-2018
$165.00