GB/T 36450.7-2021Information technology - Storage management - Part 7: Host elements (English PDF)
信息技术 存储管理 第7部分:主机元素
This is a limited preview
Buy now to download the full PDF (247 pages)
Need quotation for your management?
Get a formal quotation for GB/T 36450.7-2021 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
October 11, 2021
Implementation date
May 1, 2022
Scope
GB/T 36450.7-2021 is the English-translated version of 信息技术 存储管理 第7部分:主机元素.
GB/T 36450.7-2021 is the Chinese standard "Information technology - Storage management - Part 7: Host elements". Its scope clause reads: This document specifies the management profile of the autonomy, components and abstract profiles of host-based storage devices.
Autonomous profile Describes the management of host-based independent storage entities; component configuration files (or sub-configuration files) describe host-based, which can be used by other The management of the storage entity used by the autonomous configuration file; the abstract configuration file described in this document can be used to create other host-based autonomous The basis of governance profile.
The autonomous configuration files included in this document are. ---Host resource discovery configuration file. This configuration file specifies the storage device displayed to the operating system running on the host system Model.
In addition, this configuration file also describes the storage mapping associated with the host system that can be discovered by the client application; ---Fibre Channel HBA configuration file.
This configuration file specifies from SAN devices (Fibre Channel switches, arrays, tape libraries) Etc.) The model and function of the Fibre Channel HBA that exports the block storage to the host system; ---iSCSI initiator sub-configuration file.
This configuration file specifies the necessary models and functions to manage iSCSI initiators. Component configuration files use autonomous configuration files to describe various aspects of host-based storage elements and services.
Specified in this document Component configuration files (sub-configuration files) include. ---Host hardware RAID controller configuration file. This configuration file specifies the model and function of the host-based RAID controller.
Yes, the controller exports block storage from locally connected storage devices (built-in hard drives, JBOD, etc.) to the host system; ---Store HBA configuration files.
This configuration file specifies the model and function of SAS, SATA, SPI or Fibre Channel HBA, They export storage from SAN devices (Fibre Channel switches, arrays, tape libraries, etc.) to the host system; ---The disk partition sub-configuration file models the partition (or slice) configuration service provided by the operating system on some platforms; ---SB multi-path management sub-configuration file.
The SB multipath management sub-configuration file will be used to support the path of the SB command protocol environment (Connection between host controller and device port) modelling; ---SCSI multi-path management sub-configuration file.
The SCSI multipath management sub-configuration file will be used to support the SCSI command protocol environment The path (the connection between the host controller, device ports, and logical units) is modeled.
This document applies to the design, development, and management of host-based independent storage entities and their component configuration files (or sub-configuration files).
Found what you need?
Document preview — GB/T 36450.7-2021
National Standard of the People's Republic of China
- Classification
- L 77
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Abbreviations
- 5 Typographical Convention
- 5.1 Maturity Model
- 5.2 Experimental maturity level
- 5.3 Achieved maturity level
- 5.4 Stable maturity level
- 5.5 Completed maturity level
- 5.6 Discarded materials
- 6 Disk partition sub-configuration file
- 6.1 Description
- 6.2 Health and fault management considerations
- 6.3 Supported sub-configuration files and packages
- 6.4 Configuration file method
- 6.5 Client Precautions and Methods
- 6.6 Registered name and version
- 6.7 CIM Elements
- 7 FCHBA profile
- 7.1 Overview
- 7.2 Description
- 7.3 Implementation
- 7.4 Health and fault management considerations
- 7.5 Method
- 7.6 Client Precautions and Methods
- 7.7 CIM Elements
- 8 Store HBA configuration files
- 8.1 Summary
- 8.2 Description
- 8.3 Implementation
- 8.4 Configuration file method
- 8.5 Use Case
- 8.6 CIM elements
- 9 Host Resource Discovery Configuration File
- 9.1 Description
- 9.2 Health and fault management considerations
- 9.3 Precautions for cascading
- 9.4 Supported sub-configuration files and packages
- 9.5 External method of configuration file-StorageConfigurationService.ScsiScan
- 9.6 Client Precautions and Methods
- 9.7 Registered name and version
- 9.8 CIM elements
- 10 Host hardware RAID controller configuration file
- 10.1 Overview
- 10.2 Description
- 10.3 Implementation
- 10.4 Method
- 10.5 Examples of use
- 10.6 CIM Elements
- 11 iSCSI initiator configuration file
- 11.1 Description
- 11.2 Health and fault management considerations
- 11.3 Supported sub-configuration files and packages
- 11.4 Configuration file method
- 11.5 Client Notes and Methods
- 11.6 Registered name and version
- 11.7 CIM elements
- 12 SCSI multipath management sub-configuration file
- 12.1 Description
- 12.2 Health and fault management considerations
- 12.3 Precautions for cascading
- 12.4 Supported sub-configuration files and packages
- 12.5 Configuration file method
- 12.6 Client Precautions and Methods
- 12.7 Registered name and version
- 12.8 CIM elements
- 13 SB multi-path management sub-configuration file
- 13.1 Overview
- 13.2 Description
- 13.3 Health and fault management considerations
- 13.4 Precautions for cascading
- 13.5 Supported configuration files, sub-configuration files and packages
- 13.6 Method
- 13.7 Client Precautions and Methods
- 13.8 Registered name and version
- 13.9 CIM Elements
- Appendix A (informative) SMI-S Information Model
- References
1 Scope
This document specifies the management profile of the autonomy, components and abstract profiles of host-based storage devices. Autonomous profile
Describes the management of host-based independent storage entities; component configuration files (or sub-configuration files) describe host-based, which can be used by other
The management of the storage entity used by the autonomous configuration file; the abstract configuration file described in this document can be used to create other host-based autonomous
The basis of governance profile.
The autonomous configuration files included in this document are.
---Host resource discovery configuration file. This configuration file specifies the storage device displayed to the operating system running on the host system
Model. In addition, this configuration file also describes the storage mapping associated with the host system that can be discovered by the client application;
---Fibre Channel HBA configuration file. This configuration file specifies from SAN devices (Fibre Channel switches, arrays, tape libraries)
Etc.) The model and function of the Fibre Channel HBA that exports the block storage to the host system;
---iSCSI initiator sub-configuration file. This configuration file specifies the necessary models and functions to manage iSCSI initiators.
Component configuration files use autonomous configuration files to describe various aspects of host-based storage elements and services. Specified in this document
Component configuration files (sub-configuration files) include.
---Host hardware RAID controller configuration file. This configuration file specifies the model and function of the host-based RAID controller.
Yes, the controller exports block storage from locally connected storage devices (built-in hard drives, JBOD, etc.) to the host system;
---Store HBA configuration files. This configuration file specifies the model and function of SAS, SATA, SPI or Fibre Channel HBA,
They export storage from SAN devices (Fibre Channel switches, arrays, tape libraries, etc.) to the host system;
---The disk partition sub-configuration file models the partition (or slice) configuration service provided by the operating system on some platforms;
---SB multi-path management sub-configuration file. The SB multipath management sub-configuration file will be used to support the path of the SB command protocol environment (Connection between host controller and device port) modelling;
---SCSI multi-path management sub-configuration file. The SCSI multipath management sub-configuration file will be used to support the SCSI command protocol environment
The path (the connection between the host controller, device ports, and logical units) is modeled.
This document applies to the design, development, and management of host-based independent storage entities and their component configuration files (or sub-configuration files).
2 Normative references
The content of the following documents constitutes an indispensable clause of this document through normative references in the text. Among them, dated quotations
Only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to
This document.
GB/T 36450.2-2021 Information Technology Storage Management Part 2.Common Architecture (ISO /IEC 24775-2.2014,
MOD)
ISO /IEC 24775-3.2014 Information Technology Storage Management Part 3.Common Profile (Informationtechnolo- gy-Storagemanagement-Part 3.Commonprofiles)
ISO /IEC 24775-4.2014 Information Technology Storage Management Part 4.Block Devices (Informationtechnology-
Storagemanagement-Part 4.Blockdevices)
GB/T 42450 | GB/T 40685 | GB/T 39788 | GB/T 36450.4 | GB/T 36450.3 | GB/T 36450.5 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 247 pages — is available in the English PDF.
Referenced standards
How to Download GB/T 36450.7-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 36450.2-2021 — Information technology - Storage management - Part 2: Common architecture
GB/T 36450.8-2021 — Information technology - Storage management - Part 8: Media libraries
GB/T 36450.6-2021 — Information technology - Storage management - Part 6: Fabric
Secure payment via Stripe
Payments accepted
GB/T 36450.7-2021
$2,150.00