GB/T 36214.2-2018Plastics -- Determination of average molecular mass and molecular mass distribution of polymers using size-exclusion chromatography -- Part 2: Universal calibration method (English PDF)
塑料 体积排除色谱法测定聚合物的平均分子量和分子量分布 第2部分:普适校正法
This is a limited preview
Buy now to download the full PDF (20 pages)
Need quotation for your management?
Get a formal quotation for GB/T 36214.2-2018 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
May 14, 2018
Implementation date
December 1, 2018
Scope
GB/T 36214.2-2018 is the English-translated version of 塑料 体积排除色谱法测定聚合物的平均分子量和分子量分布 第2部分:普适校正法.
GB/T 36214.2-2018 is the Chinese standard "Plastics -- Determination of average molecular mass and molecular mass distribution of polymers using size-exclusion chromatography -- Part 2: Universal calibration method".
Its scope clause reads: This part of GB/T 36214 specifies a method for determining the average molecular weight and molecular weight distribution of polymers by volume exclusion chromatography (SEC).
Methods. The method uses a universal calibration curve instead of a conventional calibration curve to calculate the average molecular weight and molecular weight distribution.
Note 1. The bibliography related to this section is listed in the bibliography. Note 2.
The principle of the universal calibration method is based on the retention time of the polymer on the SEC depending on the molecular size of the polymer (fluidic volume) or the intrinsic viscosity The product of [eta] and the molecular weight M. Experiments have demonstrated many random coil polymers (regardless of their chemical structure, degree of branching, composition or stereoregularity) Sex) conforms to this correspondence.
The universal calibration curve is the use of polymer standards such as narrow molecular weight distribution polystyrene, eluted by lg([eta]M) Inter-t or elution volume V is plotted.
The molecular weight Mi of the unknown polymer sample can be corrected by the corresponding elution time on the universal calibration curve. [eta]M value and intrinsic viscosity [eta] or Mark-Houwink-Sakurada formula (eta[ ] = KMalpha -> eta[ ]M = K and alpha in KMalpha 1 ) are calculated, where K is a constant and alpha is an index dependent on the experimental conditions.
Therefore, this test method is as GB/T 36214.1 Described in this is a relative method in which the calculated average molecular weight and molecular weight distribution are equal to or close to their absolute values. Its clauses include terms and definitions.
Found what you need?
Document preview — GB/T 36214.2-2018
National Standard of the People's Republic of China
- ICS
- 83.080.20
- Classification
- G 31
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Foreword
- 1 Scope
- 2 Normative references
1 Scope
This part of GB/T 36214 specifies a method for determining the average molecular weight and molecular weight distribution of polymers by volume exclusion chromatography (SEC).
Methods. The method uses a universal calibration curve instead of a conventional calibration curve to calculate the average molecular weight and molecular weight distribution.
Note 1. The bibliography related to this section is listed in the bibliography.
Note 2. The principle of the universal calibration method is based on the retention time of the polymer on the SEC depending on the molecular size of the polymer (fluidic volume) or the intrinsic viscosity
The product of [eta] and the molecular weight M. Experiments have demonstrated many random coil polymers (regardless of their chemical structure, degree of branching, composition or stereoregularity)
Sex) conforms to this correspondence. The universal calibration curve is the use of polymer standards such as narrow molecular weight distribution polystyrene, eluted by lg([eta]M)
Inter-t or elution volume V is plotted. The molecular weight Mi of the unknown polymer sample can be corrected by the corresponding elution time on the universal calibration curve.
[eta]M value and intrinsic viscosity [eta] or Mark-Houwink-Sakurada formula (eta[ ] = KMalpha -> eta[ ]M =
K and alpha in KMalpha 1 ) are calculated, where K is a constant and alpha is an index dependent on the experimental conditions. Therefore, this test method is as GB/T 36214.1
Described in this is a relative method in which the calculated average molecular weight and molecular weight distribution are equal to or close to their absolute values.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 36214.1-2018 Determination of the average molecular weight and molecular weight distribution of polymers by volume exclusion chromatography - Part 1.
General Principles (ISO 16014-1.2012, IDT)
GB/T 36214.3-2018 Determination of the average molecular weight and molecular weight distribution of polymers by volume exclusion chromatography - Part 3.
Low temperature method (ISO 16014-3.2012, IDT)
GB/T 36214.4-2018 Determination of the average molecular weight and molecular weight distribution of polymers by volume exclusion chromatography - Part 4.
High temperature method (ISO 16014-4.2012, IDT)
ISO 472 plastic terminology and its definition (Plastics-Vocabulary)
3 Terms and definitions
The terms and definitions defined in ISO 472 and GB/T 36214.1-2018 apply to this document. For the convenience of using this section, here again
The definitions of the different average molecular weights are listed.
The following formula defines four average molecular weights, Ni refers to the number of i-type molecules with a molecular weight of Mi, and alpha is Mark-Houwenke-Sakurada (Mark-Houwink-Sakurada) The index in the formula.
Note. Although the formula is the same as in GB/T 36214.1, the Mi value in the following formula is calculated using the pervasive calibration curve described in Chapter 4. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 36214.1-2018Plastics -- Determination of average molecular mass and molecular mass distribution of polymers using size-exclusion chromatography -- Part 1: General principles
- GB/T 36214.3-2018Plastics -- Determination of average molecular mass and molecular mass distribution of polymers using size-exclusion chromatography -- Part 3: Low-temperature method
- GB/T 36214.4-2018Plastics -- Determination of average molecular mass and molecular mass distribution of polymers using size-exclusion chromatography -- Part 4: High-temperature method
ISO 16014 · ISO 472
How to Download GB/T 36214.2-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 36214.1-2018 — Plastics -- Determination of average molecular mass and molecular mass distribution of polymers using size-exclusion chromatography -- Part 1: General principles
GB/T 36214.3-2018 — Plastics -- Determination of average molecular mass and molecular mass distribution of polymers using size-exclusion chromatography -- Part 3: Low-temperature method
GB/T 36214.4-2018 — Plastics -- Determination of average molecular mass and molecular mass distribution of polymers using size-exclusion chromatography -- Part 4: High-temperature method
GB/T 36214.2-2018
$155.00