GB/T 36075.1-2018Acoustics -- Measurement of room acoustic parameters -- Part 1: Performance spaces (English PDF)
声学 室内声学参量测量 第1部分:观演空间
This is a limited preview
Buy now to download the full PDF (37 pages)
Need quotation for your management?
Get a formal quotation for GB/T 36075.1-2018 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
March 15, 2018
Implementation date
October 1, 2018
Scope
GB/T 36075.1-2018 is the English-translated version of 声学 室内声学参量测量 第1部分:观演空间.
GB/T 36075.1-2018 is the Chinese standard "Acoustics -- Measurement of room acoustic parameters -- Part 1: Performance spaces". Its scope clause reads: This part of GB/T 36075 specifies the measurement methods, measurement steps, and measurement settings for the reverberation time and other sound quality parameters of the viewing room.
Preparation, coverage, results evaluation, and test report formats for acoustic measurements using modern digital technologies and for impulse-based response The evaluation of the indoor sound quality parameters. Its clauses include terms and definitions.
Found what you need?
Document preview — GB/T 36075.1-2018
National Standard of the People's Republic of China
- ICS
- 91.120.20
- Classification
- A 59
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Test Condition
- 5 Measurement Method
- 6 Evaluation of the decay curve
- 7 Measurement uncertainty
- 8 space average
- 9 Result Expression
- Appendix A (informative) Hall-based sound quality parameters based on impulse response
- Appendix B (Informative) The double-chamber hall sound quality parameter 15 based on impulse response
- Appendix C (Informative) Stage-based sound quality parameters based on impulse response
1 Scope
This part of GB/T 36075 specifies the measurement methods, measurement steps, and measurement settings for the reverberation time and other sound quality parameters of the viewing room.
Preparation, coverage, results evaluation, and test report formats for acoustic measurements using modern digital technologies and for impulse-based response
The evaluation of the indoor sound quality parameters.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
IEC 61260 Electroacoustic Octave and Fractional Octave Filters (Electroacoustics-Octave-bandandfractional-
Octave-bandfilters)
IEC 61672-1 Electroacoustic Sound Level Meter Part 1. Specification (Electroacoustics-Soundlevelmeters-Part 1.
Specifications)
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Decay curve
Describes the pattern of decay of sound pressure levels over time in a room after the sound source stops sounding.
[GB/T 20247-2006, Definition 3.1]
Note 1. The decay curve can be measured either after continuous noise interruption in the room or by inverse integration of the impulse response.
Note 2. It is not recommended to directly use the curve obtained by the non-continuous sound source to accurately measure the reverberation time of the room (for example, using a starting gun as a sound source, recording with sound level)
The instrument is recorded. This method can only be used for investigative simple-level measurements. Usually the room impulse response is not simply exponentially decaying, its slope is
The results obtained from the integral of the impulse response are not the same.
3.2 Interrupted sound source method
A method of obtaining a decay curve by directly recording the decay of the sound pressure level after an excitation of a broadband or narrowband sound source in the room to interrupt the sound.
[GB/T 20247-2006, definition 3.3]
3.3 Impulse response integration method
The method of obtaining the decay curve by integrating the inverse of the square of the impulse response against time.
[GB/T 20247-2006, definition 3.4]
3.4 Impulse response
The time-varying sound pressure formed by the Dirac pulse emitted from one point in the room at another point.
GB/T 31004.1 | GB/Z 27764 | GB/T 25078.1 | GB/T 15173 | GB/T 36079 | GB/T 36075.3 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 37 pages — is available in the English PDF.
Referenced standards
Normative references
IEC 61260 · IEC 61672
How to Download GB/T 36075.1-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 36075.2-2018 — Acoustics -- Measurement of room acoustic parameters -- Part 2: Reverberation time in ordinary rooms
GB/T 36075.3-2018 — Acoustics -- Measurement of room acoustic parameters -- Part 3: Open plan offices
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film