Scope
GB/T 35125-2017 is the English-translated version of 天文望远镜试验方法.
GB/T 35125-2017 — This standard specifies the terms and definitions of astronomical telescopes, test methods. This standard applies to observation in natural light astronomical telescope, the objective lens of the aperture of 150mm and below the refractive days Binoculars and Objectives Clear aperture of 250mm and below the reflective telescope.
Found what you need?
Document preview — GB/T 35125-2017
National Standard of the People's Republic of China
- ICS
- 37.020
- Classification
- N 31
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Test methods
- 4.1 Objective aperture clear aperture
- 4.2 Refractive objective lens focal length
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard uses the redrafted method reference ISO 14490-4:2005 "Optical and optical instruments telephoto system test method part 4.
Astronomical Telescope Test Method "prepared, and ISO 14490-4:2005 consistency is not equivalent.
This standard is proposed by the China Machinery Industry Federation.
This standard by the National Standardization Technical Committee of Optics and Photonics (SAC/TC103) centralized.
This standard was drafted unit. Ningbo Cham Beijing Optical Instrument Co., Ltd., Guangzhou, Guangdong Optical Instrument Co., Ltd., Shanghai University of Technology, on Sea Optical Instrument Institute, Han's Laser Technology Industry Group Co., Ltd., Chongqing Ott Optical Instrument Co., Ltd., Ningbo Yongxin Optical Co., Ltd., Nanjing Jiangnan Yongxin Optical Co., Ltd., Ningbo Sunny Optical Instrument Co., Ltd., Nanjing East Lee to photoelectric Industrial Co., Ltd.
Division, Ningbo City Teaching Instrument Co., Ltd., Wuzhou Oka Optical Instrument Company, Ningbo Huaguang Precision Instrument Co., Ltd., Mike Audi Industrial Group Company, Guiyang Xintian Optoelectronics Technology Co., Ltd.
1 Scope
This standard specifies the terms and definitions of astronomical telescopes, test methods.
This standard applies to observation in natural light astronomical telescope, the objective lens of the aperture of 150mm and below the refractive days Binoculars and Objectives Clear aperture of 250mm and below the reflective telescope.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 35126 Telescope terminology GB/T 13962 Optical instruments terminology GB/T 25480 Instrumentation transport, storage of the basic environmental conditions and test methods JB/T 9328-1999 resolution board
3 Terms and definitions
GB/T 35126, GB/T 13962 defined terms and definitions apply to this document.
4 Test methods
4.1 Objective aperture clear aperture
4.1.1 Test Tools
Vernier caliper.
4.1.2 Test Procedure
Refractive. Use vernier caliper in the circumference of the uniform distribution of the four measurements of the inner diameter of the nosepiece.
Reflex. Use vernier caliper measurements in the four locations evenly distributed around the circumference of the mirror objective lens inscribed circle diameter or reflective objective without occlusion Department of the lens diameter.
Take the average value as the measured value, the measured value and the nominal aperture of the objective lens of the difference between the diameter of the objective lens is the aperture error.
4.2 Refractive objective lens focal length
4.2.1 Test Tools
Test tools are as follows.
a) focal length meter or optical bench;
b) reading microscope (for magnification method);
c) Boluo board (for the magnification method);
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
Referenced standards
How to Download GB/T 35125-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 13962-2009 — Optical instruments-vocabulary
GB/T 25480-2010 — Basic environmental conditions and testing methods for transportation and storage of instruments
GB/T 35126-2017 — Terms for astronomical telescopes
Secure payment via Stripe
Payments accepted
GB/T 35125-2017
$210.00