GB/T 34940.1-2017Static transfer systems (STS) -- Part 1: General and safety requirements (English PDF)
静态切换系统(STS) 第1部分:总则和安全要求
This is a limited preview
Buy now to download the full PDF (43 pages)
Need quotation for your management?
Get a formal quotation for GB/T 34940.1-2017 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Level / Type
National · Recommended
Issue date
November 1, 2017
Implementation date
May 1, 2018
Scope
GB/T 34940.1-2017 is the English-translated version of 静态切换系统(STS) 第1部分:总则和安全要求.
GB/T 34940.1-2017 — GB/T 34940 is suitable for stand-alone operation, scheduled to ensure continuous power supply load AC Static Switching System (STS). The system is two or multiple independent AC source automatically or manually interrupted or uninterrupted controlled switch.
This section GB/T 34940 specifies the general principles and safety requirements. Electromagnetic compatibility (EMC) requirements see GB/T 34940.2, certainty to methods and test requirements can see GB/T 34940.3.
The purpose of this section is to reduce the risk of fire and electric shock, as well as installation, operation and maintenance of equipment in the manner specified by the manufacturer Risk of personal injury.
This section includes the switching element and its control and protection components (if applicable) requirements, including access to STS and its accessories exchange the overall information of the grid.
STS in order to achieve the operation, control, protection, isolation of the necessary components or devices (such as circuit breakers, fuses, transformers, etc.) should meet the requirements of the relevant standards, this section does not cover.
This section applies to AC voltage not exceeding 1000V single-phase, two-phase and three-phase static switching system.
This section does not apply to. --- Switching DC source device; --- Only use the mechanical and electrical switching devices to allow the load during the switching process power supply interruption, and is intended for emergency power supply system, the static switching system System.
Such equipment is covered by IEC 60947-6-1; --- Integrated in the UPS, by the national standard "uninterruptible power supply (UPS)" covered by the automatic switching device.
Note. Scheduled for vehicles, boats, aircraft, tropical areas, emergency power supply systems (eg for medical facilities, firefighting and emergency rescue, etc.) or at an altitude of 1000m STS in the above areas may have different requirements.
Found what you need?
Document preview — GB/T 34940.1-2017
National Standard of the People's Republic of China
- ICS
- 29.240.99
- Classification
- K 85
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 General Definitions
- 3.2 Rating
- 3.3 Enter the value
- 4 Safety requirements
- 4.1 Marking and description
- 4.2 Basic Design Requirements
- 4.3 Structure Requirements
- 4.4 Heat requirements, fire and fire insurance
- 5 Electrical Requirements and Simulation Abnormal Conditions
- 5.1 Overview
- 5.2 Dielectric strength
- 5.3 Abnormal operation and fault conditions
- Appendix A (Normative) Determination of cross-sectional area of protective conductor based on thermal short-term current stress (more details
- See IEC 60364-5-54)
- Appendix B (Normative) The minimum and maximum cross-sectional area of copper conductor suitable for connection 42
- Reference
- Figure 1 Test finger
- Figure 2 test pin
- Figure 3 Test probe
- Figure 4 circuit to determine the insulation
- Figure 5 Determination of live parts and accessible surfaces between the insulation
- Figure 6 Circuit and the environment between the insulation and the insulation between the circuit
- Figure 7 Determination of functional insulation
- Figure 8 Determination of basic insulation
- Figure 9 Double Insulation or Reinforced Insulation Determination
- Table 1 Internal wiring insulation penetration
- Table 2 Protective conductor (PE, PEN) cross-sectional area
- Table 3 pollution level definition
- Table 4 Clearances between Primary Circuits and Their Environment (Impulse Withstand Voltage Overvoltage Category III)
- Table 5 Secondary circuit and its environment between the clearance (impact withstand voltage overvoltage category II)
- Table 6 Clearances within the circuit (impact withstand voltage according to overvoltage category I)
- Table 7 minimum creepage distance
- Table 8 Limits for Internal Limited Power
- Table 9 Non-intrinsically limited power supply limits (requires over-current protection device)
- Table 10 Temperature Limits. Part 1
- Table 11 Temperature Limits. Part 2
- Table A.1 is not in the cable insulation protection conductor or bare protective conductor in contact with the cable sheath k value
- Table B.1 suitable for connecting copper conductor minimum and maximum cross-sectional area
Foreword
GB/T 34940 "Static Switching System (STS)" is divided into the following sections.
--- Part 1. General and safety requirements;
--- Part 2. Electromagnetic compatibility (EMC) requirements;
--- Part 3. Determination of performance methods and test requirements.
This section GB/T 34940 Part 1.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the translation method identical with IEC 62310-1-2005 "Static Switching System (STS) Part 1. General and safety requirements." the documents of our country that are consistent with the corresponding international documents that are normative references in this section are as follows.
--- GB/T 2893.1-2013 Graphical symbols Graphical symbols Safety colors and safety signs Part 1. Safety signs and safety Fully labeled design principles (ISO 3864-1:2011, MOD)
--- GB/T 4025-2010 man-machine interface logo identifies the basic and safety rules Indicator and operating device coding rules (IEC 60073:2002, IDT) Solid insulating materials - Resistance to tracking index and comparative tracking index - Determination of method (IEC 60112).
2009, IDT)
--- GB/T 4208-2008 enclosure protection (IP code) (IEC 60529:2001, IDT)
--- GB 4943.1-2011 Information technology equipment safety Part 1. General requirements (IEC 60950-1:2005, MOD)
--- GB/T 5465 (all parts) Graphical symbols for electrical equipment (IEC 60417DB.2007, MOD)
--- GB/Z 6829-2008 Residual Current Surge Protector General Requirements (IEC/T R60755.2008, IDT)
--- GB/T 11021-2014 Electrical insulation heat resistance and representation (IEC 60085:2007, IDT) Automatic electrical controls for household and similar use - Part 1. General requirements (IEC 60730-1.:2004);
2003, IDT)
--- GB/T 16273.1-2008 Graphical symbols for use in equipment - Part 1. General symbols (ISO 7000:2004, NEQ)
--- GB/T 16895.3-2004 Electrical installations of buildings Part 5-54. Selection and installation of electrical equipment Grounding configuration, Protective conductor and protective coupling conductor (IEC 60364-5-54:2002, IDT)
--- GB/T 16895.9-2000 Electrical installations of buildings Part 7. Requirements for special installations or locations Section 707. Number According to the handling equipment electrical equipment grounding requirements (IEC 60364-7-707:1984, IDT)
--- GB/T 16916.1-2014 Residual current operated circuit breakers (RCCB) for household and similar purposes without overcurrent protection Part 1. General rules (IEC 61008-1:2012, MOD)
--- GB/T 16917.1-2014 Residual current operated circuit breakers (RCBO) with overcurrent protection for household and similar purposes Part 1. General rules (IEC 61009-1:2012, MOD) High voltage test techniques - Part 1. General definitions and test requirements (IEC 60060-1.
2006, MOD)
--- GB/T 16935.1-2008 Insulation coordination of equipment in low-voltage systems - Part 1. Principles, requirements and tests (IEC 60664-1:2007, IDT)
--- GB/T 16935.3-2016 Insulation coordination of equipment within low-voltage systems Part 3. The use of coating, canning and molding Anti-fouling protection (IEC 60664-3:2010, IDT) this section made the following editorial changes.
--- After the letter number column item "test b)" to "test a)" (see 4.2.1.1);
--- Correct "(45/U) µF" to "(45/U) nF" and "(700/U2) µF" to "(700/U2) nF" (see 4.2.3.2);
--- "S <= 800" corrected "S > 800" (see Table 2);
--- According to 2.5 of IEC 60950-1:2001, the first paragraph of 4.2.12 is corrected to "limited by the AC mains power supply Source, or battery-powered and in the load at the same time by the AC power supply when charging the limited power supply should be equipped with isolation change Pressure device. "(See 4.2.12);
--- Correct "<=1000Uoc" to "<=1000/Uoc" (see Table 9).
This part is proposed by China Electrical Equipment Industry Association.
This part of the National Power Electronic Systems and Equipment Standardization Technical Committee (SAC/TC60) centralized.
This part of the drafting unit. Guangdong Zhicheng Champion Group Co., Ltd., Huazhong University of Science and Technology, Xi'an Institute of Power Electronics, Xiamen Kehua Hengsheng Co., Ltd., China Power Supply Society, Qingdao Chuangtong Technology Development Co., Ltd., Renault (Changzhou) Electronics Co., Ltd., Zhejiang Kezheng Electronic Information Products Inspection Co., Schneider Electric Information Technology (China) Co., Ltd., Emerson Network Power Co., Zhuhai and Thailand Tan Technology Co., Ltd., Xi'an love to send Branch Power Electronics Co., Ltd., China Power Industry Association.
1 Scope
GB/T 34940 is suitable for stand-alone operation, scheduled to ensure continuous power supply load AC Static Switching System (STS). The system is two or multiple independent AC source automatically or manually interrupted or uninterrupted controlled switch.
This section GB/T 34940 specifies the general principles and safety requirements. Electromagnetic compatibility (EMC) requirements see GB/T 34940.2, certainty to methods and test requirements can see GB/T 34940.3.
The purpose of this section is to reduce the risk of fire and electric shock, as well as installation, operation and maintenance of equipment in the manner specified by the manufacturer Risk of personal injury.
This section includes the switching element and its control and protection components (if applicable) requirements, including access to STS and its accessories exchange the overall information of the grid.
STS in order to achieve the operation, control, protection, isolation of the necessary components or devices (such as circuit breakers, fuses, transformers, etc.) should meet the requirements of the relevant standards, this section does not cover.
This section applies to AC voltage not exceeding 1000V single-phase, two-phase and three-phase static switching system.
This section does not apply to.
--- Switching DC source device;
--- Only use the mechanical and electrical switching devices to allow the load during the switching process power supply interruption, and is intended for emergency power supply system, the static switching system System. Such equipment is covered by IEC 60947-6-1;
--- Integrated in the UPS, by the national standard "uninterruptible power supply (UPS)" covered by the automatic switching device.
Note. Scheduled for vehicles, boats, aircraft, tropical areas, emergency power supply systems (eg for medical facilities, firefighting and emergency rescue, etc.) or at an altitude of 1000m STS in the above areas may have different requirements.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document.
Static switching systems (STS) - Part 2. Electromagnetic compatibility (EMC) requirements (IEC 62310-2.
2006, IDT)
High voltage test techniques - Part 1. General definitions and test requirements (High - voltagetesttech -niques-Part 1: Generaldefinitionsandtestrequirements) Basic and safety rule marking of IEC 60073 man-machine interface markings and coding rules for operating devices (Basicand safetyprinciplesfor man-machineinterface, marking and identification-Coding principlesfor indicatorsandactuators) IEC 60083 IEC Member States standardized household and similar plugs and sockets (Plugsandsocket-outletsfordomestic andsimilargeneraluse, standardized member account IOW) IEC 60085 electrical insulation heat classification (Electricalinsulation-Thermal classification) IEC 60112 solid insulation material tracking resistance index and compared to the tracking index method (Methodforthedetermi-
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 43 pages — is available in the English PDF.
Referenced standards
Normative references
IEC 62310 · IEC 60073 · IEC 60083 · IEC 60085 · IEC 60112
How to Download GB/T 34940.1-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 34940.2-2017 — Static transfer systems (STS) -- Part 2: Electromagnetic compatibility (EMC) requirements
GB/T 34940.3-2017 — Static transfer systems (STS) -- Part 3: Method for specifying performance and test requirements
GB/T 9246-2026 — Microscopes - Oculars (eyepieces)
Secure payment via Stripe
Payments accepted
GB/T 34940.1-2017
$530.00