Scope

GB/T 34799-2017 is the English-translated version of 几丁质酶活性检测方法.

GB/T 34799-2017 is the Chinese national test method for the activity of chitinase.

Clause 1 states that the standard covers the detection of chitinase activity in the product obtained by fermentation of Serratia marcescens, Streptomyces griseus and Trichoderma viride, and that it applies to biochemical reagents and to the determination of chitinase activity in industrial products.

The clauses shown on the page are 1 Scope, 2 Normative references, 3 Terms and definitions, 4 principle, 5 equipment and appliances and 6 Reagents, and clause 2 cites GB/T 6682.

Clause 3 defines the chitinase activity unit as the amount of chitinase that, at 37 degrees Celsius and pH 6.0, catalyses in a two-step reaction assisted by beta-N-acetylglucosaminidase the formation of 1mg of product per minute, one such unit being written U; the name of the product formed is garbled in the draft at this point and is left out here.

Clause 4 states the principle: chitinase rapidly catalyses the hydrolysis of chitin into N-acetylglucose or into disaccharides and oligosaccharides made of it, those are hydrolysed further into N-acetylglucose with N-acetylglucosaminidase, and the N-acetylglucose produced is detected by absorbance and used to calculate the enzyme activity.

Clause 5 lists the apparatus as a pH meter, an electronic balance reading to 0.0001g, a spectrophotometer whose absorbance value is accurate to 0.001, a 1cm quartz cuvette and a constant temperature shaking shaker with a temperature control accuracy of plus or minus 0.5 degrees Celsius.

Clause 6 requires reagents of analytical grade and water meeting the grade two requirements of GB/T 6682, and the draft breaks off at that line, so the procedure and the calculation are not shown.

The standard was proposed by and is administered by the National Biochemical Test Standardization Technical Committee (SAC/TC387). The page declares no replaced edition; it was issued on November 1, 2017 and has applied since May 1, 2018.

Found what you need?

Document preview — GB/T 34799-2017

National Standard of the People's Republic of China

ICS
07.080
Classification
G 66

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Principle
  • 5 Equipment and appliances
  • 6 Reagents

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This standard specifies Serratia marcescens, Streptomyces griseus and green wood Detection of Chitinase Activity by Trichodermaviride Fermentation.

This standard applies to biochemical reagents, determination of chitinase activity in industrial products.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 6682 analytical laboratory water specifications and test methods

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 Chitinase activity unit

At 37 ° C, pH 6.0, beta-N-acetylglucosaminidase-assisted two-step reaction catalyzed the formation of 1 mg N-B per minute The amount of chitinase in acylglucose is one unit of activity, in units of U.

4 Principle

Chitinase rapidly catalyzes the hydrolysis of chitin to N-acetylglucose or disaccharides and oligosaccharides composed of N-acetylglucose, disaccharides and Oligosaccharides continue to be hydrolyzed with N-acetylglucosaminidase to N-acetylglucose, which is detectable by absorbance, Calculated N-acetyl glucose production measured enzyme activity.

5 Equipment and appliances

5.1 pH meter.

5.2 electronic balance. Feel 0.0001g.

5.3 Spectrophotometer. Absorbance value accurate to 0.001.

5.4 1cm quartz cuvette.

5.5 constant temperature shaking shaker temperature control accuracy of ± 0.5 °C.

6 Reagents

The reagents used in this standard are of analytical grade, water is in line with GB/T 6682 provisions of the two water.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 34799-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 34799-2017

$85.00