Scope

GB/T 34579-2017 (Methods of measurement and limits for radiated disturbances from plasma display panel equipment in the frequency range 150 kHz to 30 MHz) is available as an English-translated PDF.

GB/T 34579-2017 - This Standard specifies the methods of measurement and limits for radiated disturbances from plasma display panel equipment 150 kHz ~ 30 MHz.

This Standard is applicable to plasma display panel equipment with a visible display area of 1 m or a larger diagonal intended for use in residential or commercial environments within the scope of GB/T 13837-2012 or CISPR 32.

The corresponding frequency range of the radiofrequency radiated disturbances described in this Standard is 150 kHz ~ 30 MHz. This Standard specifies corresponding limits and measurement methods for the evaluation of radiofrequency radiated disturbances.

The limit requirements specified in this Standard are the basic requirements of EMC. The requirements aim at avoiding affecting the radio reception in the 150 kHz ~ 30 MHz frequency range of the area when the display panel equipment are working.

While adopting this Standard, other regulations on EMC radiated emission shall be implemented in accordance with GB/T 13837-2012 and CISPR 32. This Standard is a supplement to the requirements of other related standards on electromagnetic compatibility.

The purposes of this Standard are as follows: a) Establish supplementary requirements to properly protect the frequency spectrum in the frequency range of 150 kHz ~ 30 MHz, so that the expected radio reception in this frequency range can be normally used; b) In order to ensure the reproducibility of measurement and the repeatability of measurement results, specific measurement procedures are specified.

Found what you need?

Document preview — GB/T 34579-2017

National Standard of the People's Republic of China

ICS
33.100.10
Classification
M 74

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Normative References...4
  • 3 Terms and Definitions...5
  • 4 Limits...5
  • 5 Measurement Requirements...6
  • 6 Measurement Layout and Procedures...8
  • 7 Standard Compliance...9
  • Bibliography...11

Foreword

This Standard was drafted in accordance with the rules in GB/T 1.1-2009.

This Standard adopts the re-drafting law in the modification and adoption of IEC/PAS

62825:2013 Methods of Measurement and Limits for Radiated Disturbances from

Plasma Display Panel TVs in the Frequency Range 150 kHz to 30 MHz.

In comparison with IEC/PAS 62825:2013, the technical differences and the causes for

these differences are as follows:

---In terms of Normative References, this Standard adjusts the technical

differences, so as to adapt to the technical conditions of our country. The

adjustments are intensively reflected in Chapter 2 "Normative References". See

the specific adjustments below:

lambda CISPR 32 is modified into reference without year number (see Chapter 1);

lambda The reference of GB 3174 is added (see 5.5);

lambda The reference of GB 4824-2013 is added (see Table 1).

---The scope of application is expanded from plasma TVs to plasma display panel

equipment;

---The NOTE in Table 1 is modified into the main text;

---5.5 "EUT Working Status" is rewritten.

This Standard was proposed by and shall be under the jurisdiction of National

Technical Committee 79 on Radio Jamming of Standardization Administration of China

(SAC/TC 79).

The drafting organizations of this Standard: The 3rd Research Institute of China

Electronics Technology Group Corporation; Xiamen GOPRO Guangpu Electronics Co.,

Ltd.

1 Scope

This Standard specifies the methods of measurement and limits for radiated

disturbances from plasma display panel equipment 150 kHz ~ 30 MHz.

This Standard is applicable to plasma display panel equipment with a visible display

area of 1 m or a larger diagonal intended for use in residential or commercial

environments within the scope of GB/T 13837-2012 or CISPR 32.

The corresponding frequency range of the radiofrequency radiated disturbances

described in this Standard is 150 kHz ~ 30 MHz. This Standard specifies corresponding

limits and measurement methods for the evaluation of radiofrequency radiated

disturbances.

The limit requirements specified in this Standard are the basic requirements of EMC.

The requirements aim at avoiding affecting the radio reception in the 150 kHz ~ 30

MHz frequency range of the area when the display panel equipment are working.

While adopting this Standard, other regulations on EMC radiated emission shall be

implemented in accordance with GB/T 13837-2012 and CISPR 32. This Standard is a

supplement to the requirements of other related standards on electromagnetic

compatibility.

The purposes of this Standard are as follows:

a) Establish supplementary requirements to properly protect the frequency

spectrum in the frequency range of 150 kHz ~ 30 MHz, so that the expected

radio reception in this frequency range can be normally used;

b) In order to ensure the reproducibility of measurement and the repeatability of

measurement results, specific measurement procedures are specified.

2 Normative References

The following documents are indispensable to the application of this document. In

terms of references with a specified date, only versions with a specified date are

applicable to this document. In terms of references without a specified date, the latest

version (including all the modifications) is applicable to this document.

GB 3174 Characteristics of PAL-D Television Broadcasting System

GB/T 4365 Electrotechnical Terminology - Electromagnetic Compatibility (GB/T 4365-

2003, IEC 60050 (161): 1990 + AMD 1: 1997, IDT)

GB 4824-2013 Industrial, Scientific and Medical Equipment - Radio-frequency

Disturbance Characteristics - Limits and Methods of Measurement (CISPR 11: 2010,

IDT)

GB/T 6113.101-2016 Specification for Radio Disturbance and Immunity Measuring

Apparatus and Methods of Measurement - Part 1-1: Radio Disturbance and Immunity

Measuring Apparatus - Measuring Equipment (CISPR 16-1-1: 2010, IDT)

GB/T 6113.104-2016 Radio Disturbance and Immunity Measuring Apparatus and

Methods - Part 1-4: Radio Disturbance and Immunity Measuring Apparatus - Radiated

Disturbance Measuring Antenna and Test Site (CISPR 16-1-4: 2010, IDT)

GB/T 13837-2012 Sound and Television Broadcast Receivers and Associated

Equipment - Radio Disturbance Characteristics - Limits and Methods of Measurement

(IEC/CISPR 13:2009, MOD)

CISPR 32 Electromagnetic Compatibility of Multimedia Equipment - Emission

Requirements

3 Terms and Definitions

What is defined in GB/T 4365 and GB/T 13837-2012, and the following terms and

definitions are applicable to this Standard.

3.1 Boundary of the EUT

Boundary of the EUT refers to the smallest imaginary circle surrounding the equipment

under test (including all connecting cables).

4 Limits

4.1 Overview

The equipment specified in the scope of this Standard shall be measured at a

standardized radiation test site. Open fields or semi-anechoic chambers are preferred

(although these sites are verified in the frequency range of 30 MHz ~ 1 GHz in

accordance with GB/T 6113.104-2016).

The measuring equipment and methods of measurement are specified in Chapter 5

6 Measurement Layout and Procedures

6.1 Measurement Layout

The EUT shall be placed on a non-metallic test bench that is 80 cm above the

grounding plane. The distance between the center of the loop antenna and the

boundary of the equipment under test shall be 3 m, as it is shown in Figure 1.

When the EUT is equipped with a dedicated grounding terminal, use the shortest

possible grounding wire to ground this grounding terminal. When the EUT is not

equipped with a dedicated grounding terminal, it shall be tested under normal

conditions of connection, for example, grounding through a power line or a coaxial

signal line.

6.2 Measurement Procedures

In the axial and parallel directions of the two antennas, respectively measure the

radiated emission. The loop of the antenna defines a plane, and a horizontal line shall

simultaneously pass through the center line of the antenna and the EUT. When the line

connecting the horizontal line and the EUT is in the plane of the antenna loop, the

antenna direction at this moment is defined as the parallel direction. When the line

connecting the horizontal line and the EUT is perpendicular to the plane of the antenna

loop, the antenna direction at this moment is defined as the axial direction. The two

antenna directions are shown in Figure 2.

For the EUT placed on the rotary table, the rotary table shall thoroughly rotate, and the

measurement shall be conducted in the above-mentioned two antenna directions. In

addition, record the highest electromagnetic radiated disturbance level of each

frequency.

For the EUT not placed on the rotary table, the loop antenna shall be placed in at least

4 orthogonal positions 3 m away from the EUT; each position shall be measured in the

above-mentioned two antenna directions.

6.3 Expression of Measurement Results

All results obtained from the radiated disturbance measurement shall be recorded in

the test report. If the results in the frequency range being measured are not recorded

in a continuous mode and / or in the form of a chart, then, the results shall at least

include the following content.

When the radiated emission margin is less than 10 dB, at least the 6 highest

disturbance field strengths, disturbance frequencies, antenna polarization directions

(axial or parallel) and rotary table angles shall be recorded.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 34579-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
11 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 34579-2017

$145.00