GB/T 34482-2017 is the English-translated version of 建筑用铝合金隔热型材传热系数测定方法.
GB/T 34482-2017 is the Chinese standard "Determination of Thermal Transmittance for Architecture Aluminum Alloy Thermal Barrier Profiles".
Its scope clause reads: This Standard stipulates the terms, definitions, method and principle, test equipment and devices, test sample, determination and test report for the determination of thermal transmittance for architecture aluminum alloy thermal barrier profiles.
This Standard is applicable to the determination of thermal transmittance for architecture aluminum alloy thermal barrier profiles. Its clauses include terms and definitions; method and principle; test equipment and devices; test sample; determination; test report.
It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on OCTOBER 14, 2017 and took effect on JULY 1, 2018.
Found what you need?
Document preview — GB/T 34482-2017
National Standard of the People's Republic of China
- ICS
- 77.040.99
- Classification
- H 21
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative References4
- 3 Terms and Definitions4
- 4 Method and Principle5
- 5 Test Equipment and Devices5
- 6 Test Sample7
- 7 Determination8
- 8 Test Report13
- Appendix A (Normative) Heat Flow Coefficient Calibration Method14
1 Scope
This Standard stipulates the terms, definitions, method and principle, test equipment and devices, test sample, determination and test report for the determination of thermal transmittance for architecture aluminum alloy thermal barrier profiles.
This Standard is applicable to the determination of thermal transmittance for architecture aluminum alloy thermal barrier profiles.
2 Normative References
The following documents are indispensable to the application of this document. In terms of references with a specific date, only versions with a specific date are applicable to this document. In terms of references without a specific date, the latest versions (including all the modification lists) are applicable to this document.
GB/T 4132 Definitions of Terms Relating to Thermal Insulating Materials
GB/T 8170 Rules of Rounding off for Numerical Values & Expression and Judgement of Limiting Values
GB/T 10294 Thermal Insulation - Determination of Steady-state Thermal Resistance and Related Properties - Guarded Hot Plate Apparatus
GB/T 13475 Thermal Insulation - Determination of Steady-state Thermal Transmission
Properties - Calibrated and Guard Hot Box
JJG 368-2000 Working Copper/Copper-Nickel Thermocouple
3 Terms and Definitions
Terms and definitions defined in GB/T 4132, and the following terms and definitions are applicable to this document.
3.1 Areal Density of Heat Flow Rate
q
Areal density of heat flow rate refers to per unit area heat flow, which is vertical to the
0.04 W/(m-K). The actual value of thermal transmittance shall be provided by manufacturers, or, be determined in accordance with the methods stipulated in GB/T
10294. The parallelism of both sides of the thermal insulation board shall be not more than ± 0.5°. Thermal insulation board for calibration, which is known as calibration board for short, has the thickness of 20 mm or 60 mm.
5.4 Test Piece Frame
The texture of test piece frame shall comply with the stipulations in GB/T 13475. The thermal transmittance shall be not more than 0.04 W/(m-K). The thickness of test piece frame shall be not less than 300 mm.
5.5 Hot Box External Wall
The texture of hot box external wall shall comply with the stipulations in GB/T 13475.
The thermal transmittance shall be not more than 0.04 W/(m-K). The thickness of hot box external wall shall be not less than 200 mm.
5.6 Hot Box Calibration
5.6.1 Parameters that the hot box needs to calibrate include: hot chamber external wall heat flow coefficient M1 and test piece frame heat flow coefficient M 2.
5.6.2 When the cold chamber draught fan of the hot box is constant-speed fan, the wind speed of the cold chamber draught fan shall be 3 m/s. In accordance with the methods in Appendix A, calibrate hot chamber external wall heat flow coefficient M 1 and test piece frame heat flow coefficient M 2.
5.6.3 When the cold chamber draught fan of the hot box is adjustable-speed fan, in accordance with the methods in Appendix B, set up the wind speed. Then, in accordance with the methods in Appendix A, calibrate hot chamber external wall heat flow coefficient M1 and test piece frame heat flow coefficient M 2.
5.6.4 Hot box calibration shall be conducted at least once a year. If the location, structure or accessory of hot box changes, re-calibration will be needed.
6 Test Sample
In accordance with hot box’s hole size, cut-take samples. The cutting inclination of the samples shall be ± 0.5°. The total effective projected area of the samples shall be not less than 30% of the hole area of the hot box. The effective projected area of sample refers to the larger one in the projected areas of both-side metal profile, indoors and outdoors, of the thermal barrier profile. Please refer to Figure 2 for the selection of effective projected area A f of an individual sample. The sum of effective projected areas of multiple samples adopted in one test shall be considered as the total effective projected area of the samples.
various measured parameters (energy consumption value of maintaining constant hot chamber temperature; internal and external surface temperature of hot chamber external wall; temperature of test piece frame hot side surface and cold side surface;
air temperature of hot chamber and cold chamber; temperature of thermal insulation board hot side surface and cold side surface) as a group of data.
7.6 Result Calculation
7.6.1 In accordance with Formula (1), calculate the thermal conductivity of
thermal insulation board. The numerical value rounding-off rule shall comply with relevant stipulations in GB/T 8170. The result shall retain 2 decimal places.
Where,
---thermal conductivity of thermal insulation board (reciprocal of thermal insulation board’s thermal resistance), expressed in [W/(m
2
-K)];
lambda---thermal conductivity coefficient of thermal insulation board, expressed in [W/(m-K)];
d---thickness of thermal insulation board, expressed in (m).
7.6.2
In accordance with Formula (2), calculate thermal transmittance coefficient K.
The numerical value rounding-off rule shall comply with relevant stipulations in GB/T
8170. The result shall retain 2 decimal places.
Where,
K---thermal transmittance coefficient, expressed in [W/(m
2
-K)];
Phiin ---energy consumption of maintaining constant hot chamber temperature, expressed in (W);
Deltathetaek ---average temperature difference between internal and external surface of hot chamber external wall, expressed in (K);
Deltathetasur ---average temperature difference between test piece frame hot side surface and cold side surface, expressed in (K);
Deltathetan ---during test, air temperature difference between hot chamber and cold chamber,
Appendix A (Normative)
Heat Flow Coefficient Calibration Method
A.1 An Overview of Method
Adopt a calibration board, whose thickness is around 60 mm. Transform the temperature difference between the hot chamber and the external environment; the temperature difference between the cold chamber and the hot chamber. Calculate hot chamber external wall heat flow coefficient M 1 and test piece frame heat flow coefficient
M 2.
A.2 Calibration of Heat Flow Coefficient
A.2.1 In accordance with B.2.1, install a calibration board, whose thickness is around
60 mm.
A.2.2 In accordance with B.2.2, install a thermocouple.
A.2.3 Set up the test ambient temperature of the hot box to be 25 °C; relative ambient humidity shall be not more than 60%. In accordance with 7.4, set up hot box test conditions. In accordance with 7.5, record the first piece of data.
A.2.4 Set up the test ambient temperature of the hot box to be 20 °C. Maintain the ambient humidity and the hot box test conditions unchanged, comply with 7.5 to record the second piece of data.
A.2.5 In accordance with (A.1) and (A.2) simultaneous equations, calculate hot
chamber external wall heat flow coefficient M 1 and test piece frame heat flow coefficient
M 2. The numerical value rounding-off rule shall comply with relevant stipulations in
GB/T 8170. The result shall retain 3 decimal places.
Where,
Phiin,1, Phiin,2---hot chamber heating power in the first and the second record, expressed in (W);
Deltathetaek,1 , Deltathetaek,2 ---average temperature difference between internal and external surface of hot chamber external wall in the first and the second record, expressed in (K);
Appendix B (Normative)
Cold Chamber Draught Fan Speed Setting Method
B.1 An Overview of Method
Adopt a calibration board, whose thickness is around 20 mm. Operate the equipment, calculate the total surface thermal resistance of the calibration board. Through adjustment of the wind speed of the cold chamber draught fan, make the total surface thermal resistance of the calibration board reach the stipulated value. Then, adopt the wind speed of the cold chamber draught fan at that moment as the set value of the cold chamber draught fan speed in the subsequent calibration and determination.
B.2 Cold Chamber Draught Fan Speed Setting
B.2.1 In the test piece frame, near the hot chamber, place a calibration board, whose thickness is around 20 mm. The end face of the calibration board shall tightly cling to the test piece frame. Both sides of the calibration board shall not exceed the surface of the test piece frame, as it is shown in Figure 1. Use sealing gum to seal up the installation clearance.
B.2.2 In accordance with GB/T 13475, or, hot box instruction, install thermocouple in
hot box space, and on hot chamber external wall and test piece frame. On the calibration board, comply with area to uniformly distribute thermocouple, as it is shown in Figure B.1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 4132Thermal insulation - Vocabulary
- GB/T 8170Rules of rounding off for numerical values & expression and judgement of limiting values
- GB/T 10294Thermal insulation -- Determination of steady-state thermal resistance and related properties -- Guarded hot plate apparatus
- GB/T 13475Thermal insulation -- Determination of steady-state thermal transmission Properties -- Calibrated and guard hot box
JJG 368-2000
Similar standards
How to Download GB/T 34482-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10294-2008 — Thermal insulation -- Determination of steady-state thermal resistance and related properties -- Guarded hot plate apparatus
GB/T 13475-2008 — Thermal insulation -- Determination of steady-state thermal transmission Properties -- Calibrated and guard hot box
GB/T 4132-2023 — Thermal insulation - Vocabulary
Secure payment via Stripe
Payments accepted
GB/T 34482-2017
$125.00