GB/T 33888-2017Non-destructive testing instruments—Characterization and verification of ultrasonic thickness measuring equipment (English PDF)
无损检测仪器 超声测厚仪特性与验证
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 33888-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
July 12, 2017
Implementation date
February 1, 2018
Scope
GB/T 33888-2017 is the English-translated version of 无损检测仪器 超声测厚仪特性与验证.
GB/T 33888-2017 is the Chinese national standard for characterising and verifying a pulse echo ultrasonic thickness gauge.
It covers both the straight digital reading and the waveform display types, used with a single or a twin crystal probe, and it fixes the general requirements the instrument and its probe have to satisfy, the information a manufacturer's technical specification has to carry about the display, the transmitter and the receiver, and the material, shape and size of the calibration block.
The tests come in three groups, from temperature stability, low battery warning and working time to pulse repetition frequency, transmit pulse shape, receiver frequency range, the smallest and largest thickness measurable, accuracy and resolution, the sound velocity setting and the storage of calibrations and data. It was issued on 12 July 2017 and has applied since 1 February 2018.
Found what you need?
Document preview — GB/T 33888-2017
National Standard of the People's Republic of China
- ICS
- 19.100
- Classification
- N 77
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 normative reference document
- 3 Terms and definitions
- 4 General requirements
- 5 Technical specification for ultrasonic thickness measurement equipment
- 5.1 General conditions
- 5.2 Common attributes
- 5.3 Display
- 5.4 Transmitter
- 5.5 Receiver
- 5.6 Other information
- 6 calibration test block
- 6.1 General conditions
- 6.2 Materials
- 6.3 shape and size
- 7 ultrasonic thickness measurement equipment performance requirements
- 8 probe
- 9 Group 1 Test
- 9.1 Basic requirements
- 9.2 Equipment requirements for Group 1 testing
- 9.3 Temperature stability
- 9.4 Low battery warning
- 9.5 Power working time
- 9.6 Operating voltage range
- 9.7 Operating current range
- 9.8 Operating temperature range
- 9.9 pulse repetition frequency, PRF
- 9.10 Transmit pulse shape, rise time and peak voltage
- 9.11 Receiver operating frequency range
- 9.12 minimum and maximum measured thickness
- 9.13 Accuracy and resolution
- 9.14 Sound speed range setting (calibration)
- 9.15 Calibration mechanism
- 9.16 Calibration Settings Storage
- 9.17 data storage
- 9.18 print
- 9.19 Display and call
- 9.20 Display response time
- 10 Group 2 Tests
- 10.1 General Technology
- 10.2 Equipment requirements for Group 2 testing
- 10.3 General characteristics
- 10.4 General mechanical conditions and external conditions
- 11 Group 3 Test
- 11.1 General Technology
- 11.2 General mechanical conditions and external conditions
- 11.3 Calibration mechanism
- 11.4 Calibration Setup Storage
- 11.5 data storage
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard specifies the method and acceptance criteria for evaluating the performance of pulse echo ultrasonic thickness measurement instruments.
This standard includes straight (digital) read and waveform display types, using a single probe or twin crystal probe.
This standard applies to GB/T 27664 series of standards for the thickness of the equipment validation.
2 Normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 699 high quality carbon structural steel
GB/T 12604.1 Non - destructive testing - Terminology - Ultrasonic testing
GB/T 27664.2 Non-destructive testing - Performance and verification of ultrasonic testing equipment - Part 2: Probes
3 Terms and definitions
GB/T 12604.1 Definitions of terms and definitions apply to this document.
4 General requirements
Ultrasonic thickness measurement equipment should meet the following conditions.
a) Ultrasonic instruments and probes shall comply with the technical requirements of this standard;
b) Declaration of conformity issued by an organization with ISO 9001 certification, or an organization such as an ultrasound product quality supervision and inspection center The test certificate, or the internal test of the test report;
c) Ultrasonic instruments and probes shall clearly identify the manufacturer, model and series and unique serial number;
d) instructions for use of specific models and series of ultrasound equipment;
e) According to this standard in the manufacturer's technical specifications in the corresponding model and series of ultrasonic equipment performance indicators.
Note: The manufacturer's technical specifications do not fully constitute the required certification for b).
5 Technical specification for ultrasonic thickness measurement equipment
5.1 General conditions
For a certain type of ultrasonic thickness measurement equipment, its technical specifications should contain at least the information listed in 5.2 ~ 5.5. Tests based on Chapter 7 Test the values obtained as nominal values and tolerances.
5.2 Common attributes
The details are as follows. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 33888-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12604.1-2020 — Non-destructive testing - Terminology - Ultrasonic testing
GB/T 27664.2-2026 — Non-destructive testing instruments - Characterization and verification of ultrasonic test equipment - Part 2: Probes
GB/T 699-2015 — Quality carbon structure steels
Secure payment via Stripe
Payments accepted
GB/T 33888-2017