GB/T 33611-2017Textiles—Determination of short chain 4-(1,1,3,3-tetramethylbutyl)phenol ethoxylate (English PDF)
纺织品 短链对特辛基苯酚乙氧基化物的测定
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 33611-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
May 12, 2017
Implementation date
December 1, 2017
Scope
GB/T 33611-2017 is the English-translated version of 纺织品 短链对特辛基苯酚乙氧基化物的测定.
GB/T 33611-2017 is the Chinese test method for the short chain ethoxylates of 4-(1,1,3,3-tetramethylbutyl)phenol in textiles, that is the mono-, di- and triethoxylate of 4-tert-octylphenol.
The specimen is cut small, extracted with methanol in an ultrasonic bath, the extract is concentrated and made up in isopropanol, and the three compounds are separated by normal phase high performance liquid chromatography on a silica gel column with a fluorescence detector and quantified against an external standard.
The standard gives the principle, the reagents and standard solutions, the apparatus, the sample pre-treatment, the determination, the calculation, the lower limit of determination and the precision, and the content of the test report.
It applies to all types of textile products and cites GB/T 6682. It was issued on 12 May 2017 and has applied since 1 December 2017.
Found what you need?
Document preview — GB/T 33611-2017
National Standard of the People's Republic of China
- ICS
- 59.080.01
- Classification
- W 04
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative References4
- 3 Principle4
- 4 Reagent and Standard Solution5
- 5 Apparatus and Materials5
- 6 Sample Pre-Treatment6
- 7 Determination6
- 8 Result Calculation7
- 9 Determination Low Limit of Method and Precision8
- 10 Test Report8
- Appendix A (Informative) Normal Phase HPLC Reference Retention Time and Chromatogram of Short Chain 4-(1,1,3,3-Tetrametylbutyl) Phenol Ethoxylate Standard Product9
Foreword
This Standard was drafted as per the rules specified in GB/T 1.1-2009.
1 Scope
This Standard specifies the method of adopting the normal phase High Performance Liquid Chromatography (HPLC) to determine the 3 kinds of short chain 4-(1, 1, 3, 3-tetrametylbutyl) phenol ethoxylate, namely, 4-tert-octylphenol monoethoxylate, 4-tert-octylphenol diethoxylate, 4-tert-octylphenol triethoxylate in the textiles. This Standard is applicable to all types of textile products.
2 Normative References
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document.
GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods
3 Principle
Take methanol as the extraction solvent; use ultrasonic wave to extract short chain 4-(1, 1, 3, 3-tetrametylbutyl) phenol ethoxylate in the specimen; concentrate the extracting solution, then use normal phase high performance liquid chromatography with fluorescence detector to determine; use external standard method to determine the quantity.
6 Sample Pre-Treatment
Select the representative sample; cut into 5mm × 5mm pieces, mix evenly. Weigh 2g of specimen, accurate to 0.01g; place into the stoppered conical flask (5.4); add 50mL of methanol (4.1), extract for 40min under the room temperature in the ultrasonic-wave generator (5.2); transfer the extracting solution into the round bottom flask (5.5); then use 10mL of methanol (4.1) to wash the slag, add into the extracting solution.
Concentrate to 1mL at 40°C rotary evaporator (5.6); then use isopropanol (4.3) to make the constant volume of 10mL. Filter the solution through the organic phase filter membrane (5.7), then serve as the sample solution to be tested by the normal phase high performance liquid chromatography.
7 Determination
7.1 Normal phase high performance liquid chromatography conditions
Since the test results depend on the instrument used; it is not possible to give general parameters for chromatographic analysis. The following parameters have been proved to be appropriate for the test.
a) Chromatographic column: Dikma platisil silica gel column; 250mm × 4.6mm, 5.0µm or equivalent.
b) Chromatographic column temperature: 35°C.
c) Mobile phase:
--- Mobile Phase A: n-hexane + isopropanol (85:15);
--- Mobile Phase B: isopropanol + water (85:15).
d) Fluorescence detector: excitation wavelength of 230nm; emission wavelength of 296nm.
e) Flow rate: 0.5mL/min.
f) Sample injection volume: 10µL.
g) Gradient elution program, refer to Table 1. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 33611-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-1992 — Water for analytical laboratory use--Specification and test methods
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 33611-2017
$75.00