Valid

GB/T 32794-2016Pig iron contenting nickel—Determination of nickel,cobalt,chromium,copper,phosphorus content—Inductively coupled plasma atomic emission spectrometry (English PDF)

含镍生铁 镍、钴、铬、铜、磷含量的测定 电感耦合等离子体原子发射光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 32794-2016 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

August 29, 2016

Implementation date

July 1, 2017

Scope

GB/T 32794-2016 is the English-translated version of 含镍生铁 镍、钴、铬、铜、磷含量的测定 电感耦合等离子体原子发射光谱法.

GB/T 32794-2016 is the Chinese standard "Pig iron contenting nickel - Determination of nickel, cobalt, chromium, copper, phosphorus content - Inductively coupled plasma atomic emission spectrometry".

Its scope clause reads: This standard specifies the determination of nickel, cobalt, chromium, copper, phosphorus content, by the inductively coupled plasma atomic emission spectrometry.

This standard applies to the determination of the content of nickel, cobalt, chromium, copper, phosphorus in pig iron contenting nickel. The content range of the determined element is as shown in Table 1.

Its clauses include principle; reagents; instruments; sampling and sample preparation; analytical procedures; calculation of results; tolerance; test report. It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on AUGUST 29, 2016 and took effect on JULY 01, 2017.

Found what you need?

Document preview — GB/T 32794-2016

National Standard of the People's Republic of China

ICS
77.100
Classification
H 11

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Principle5
  • 4 Reagents5
  • 5 Instruments7
  • 6 Sampling and sample preparation9
  • 7 Analytical procedures9
  • 8 Calculation of results10
  • 9 Tolerance11
  • 10 Test report11
  • Appendix A (Normative) Standard operation of measuring instrument13

1 Scope

This standard specifies the determination of nickel, cobalt, chromium, copper, phosphorus content, by the inductively coupled plasma atomic emission spectrometry.

This standard applies to the determination of the content of nickel, cobalt, chromium, copper, phosphorus in pig iron contenting nickel. The content range of the determined element is as shown in Table 1.

2 Normative references

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) is applicable to this standard.

GB/T 4010 Ferroalloys sampling and preparation of samples for chemical temperature). Place it in a 250 mL beaker. Add 120 mL of nitric acid (2 + 3).

Cover a watch glass. Heat to dissolve completely. Cool to room temperature.

Transfer it into a 1 L volumetric flask. Use water to dilute it to the mark. Mix well.

1 mL of this solution contains 4 mg of nickel.

4 Reagents

4.10 Cobalt standard solution

4.10.1 Cobalt standard solution, 1 mg/mL

Weigh 1.0000 g of metallic cobalt (above 99.99%) in a 250 mL beaker. Add 40 mL of nitric acid (1 + 1). Heat to dissolve it completely. Cool to room temperature.

Transfer it into a 1 L volumetric flask. Use water to dilute it to the mark. Mix well.

1 mL of this solution contains 1 mg of cobalt.

4.10.2 Cobalt standard solution, 200 µg/mL

Pipette 20.00 mL of cobalt standard solution (4.10.1) in a 100 mL volumetric flask. Use water to dilute it to the mark. Mix well. 1 mL of this solution contains 200 µg of cobalt.

4.11 Chromium standard solution, 1 mg/mL

Weigh 2.8289 g of reference potassium dichromate (baked at 180 °C for 1 h in advance, placed in a desiccator, cooled to room temperature). Put it in a 250 mL beaker. Add appropriate amount of water to dissolve it. Transfer it into a 1 L volumetric flask. Use water to dilute it to the mark. Mix well. 1 mL of this solution contains 1 mg of chromium.

4.12 Copper standard solution

4.12.1 Copper standard solution, 1 mg/mL

Weigh 1.0000 g of pure copper (above 99.99%, stored in a desiccator at room temperature). Place it in a 250 mL beaker. Add 30 mL of nitric acid (1 + 1). Heat to dissolve it, at low temperature. Cool to room temperature. Transfer it into a 1 L volumetric flask. Use water to dilute it to the mark. Mix well. 1 mL of this solution contains 1 mg of copper.

4.12.2 Copper standard solution, 100 µg/mL

Pipette 10.00 mL of copper standard solution (4.12.1), in a 100 mL volumetric flask. Use water to dilute it to the mark. Mix well. 1 mL of this solution contains 100 µg of copper.

4.13 Phosphorus standard solution

4.13.1 Phosphorus standard solution, 1 mg/mL

Weigh 4.3940 g of reference dipotassium hydrogen phosphate (dried in advance at 105 °C to a constant amount). Place it in a 250 mL beaker. Add an appropriate amount of water to dissolve it. Transfer it into a 1 L volumetric flask.

Use water to dilute it to the mark. Mix well. 1 mL of this solution contains 1 mg of phosphorus.

4.13.2 Phosphorus standard solution, 20 µg/mL

Pipette 2.00 mL of phosphorus standard solution (4.13.1), in a 100 mL volumetric flask. Use water to dilute it to the mark. Mix well. 1 mL of this solution contains 20 µg of phosphorus.

4.14 Reagent blank stock solution

Weigh 2.5 g of ammonium fluoride. Place it in a 500 mL beaker. Add 20 mL of water and 40 mL of perchloric acid. Heat it, until white smoke is generated.

Remove and cool it. Add 50 mL of hydrochloric acid (1 + 1). Heat to boil.

Remove and cool to room temperature. Transfer it into a 500 mL volumetric flask. Use water to dilute it to the mark. Mix well.

5 Instruments

In addition to the usual laboratory instruments and equipment, an inductively coupled plasma atomic emission spectrometer is used in the analysis. A high-salt atomizer is equipped, if necessary. After optimization, the instrument shall meet the following requirements: […]

5.1 General requirements

Initially adjust the inductively coupled plasma atomic emission spectrometer, according to the recommendations of the instrument manufacturer AND the requirements of laboratory analysis.

5.2 Actual resolution of instrument

Calculate the bandwidth of each used analysis line; the bandwidth shall be less than 0.030 nm.

5.3 Analytical spectral lines

This standard does not specify a special analysis line. The recommended analysis line is as listed in Table 2. During use, it shall check the interference of the spectral lines.

6 Sampling and sample preparation

Take samples in accordance with the provisions of GB/T 4010. All the easy-to-break specimens shall pass through 0.125 mm sieve holes. All the hard-to-break specimens (drilled) shall also pass through 1.60 mm sieve holes; take the specimens above the 0.154 mm sieve.

7 Analytical procedures

7.1 Sample amount

Weigh 0.20 g of sample, accurate to 0.0001 g.

7.2 Blank test

Pipette an iron solution (4.8), which contains similar amount of iron in the sample. Do a blank test with the sample.

7.3 Decomposition of sample

7.3.1 Place the sample (7.1) in a 250 mL polytetrafluoroethylene beaker. Add 10 mL of ammonium fluoride solution (4.7). Let it stand for 2 min ~ 3 min. Add 20 mL of nitric acid (4.3) and 10 mL of hydrochloric acid (4.2). Slowly heat to dissolve. Then add 8 mL of perchloric acid (4.4). Continue to heat, until the beaker is just filled with white smoke. Immediately remove it and cool it slightly.

Add 20 mL of water and 10 mL of hydrochloric acid (4.6). Heat to boil it. Cool it to room temperature. Transfer it into a 200 mL volumetric flask. Use water to dilute it to the mark. Mix well. Filter it under dry state.

7.3.2 If the sample is not completely dissolved, follow step of 7.3.1, until the procedure that "Add 20 mL of water and 10 mL of hydrochloric acid (4.6). Heat to boil it. Cool it to room temperature". Use medium-speed quantitative filter paper to filter it into a 200 mL volumetric flask. Use water to rinse the beaker 2 ~ 3 times. Rinse the filter paper 4 ~ 5 times. Retain the filtrate. Move the filter paper together with the residue into a platinum crucible. Ash it in a low temperature furnace at 700 °C ~ 750 °C. Take out the crucible. Cool it. Add 1 g of mixed flux (4.1). Put it in a 700 °C ~ 750 °C low temperature furnace, to melt for 20 minutes. Then move it into a 900 °C ~ 1000 °C high temperature furnace, to melt it for 5 ~ 8 minutes. Take out the crucible. Cool it. Leach it in a 250 mL glass beaker, which contains a small amount of water. Add 5 mL of hydrochloric acid (4.2). Wash the crucible clean. Heat to boil it. Cool to room temperature.

Move it into a 200 mL volumetric flask, to combine with the original filtrate. Use water to dilute it to the mark. Mix well.

7.4 Preparation of calibration curve solution

Appendix A (Normative) Standard operation of measuring instrument

A.1 Purpose

The purpose of the performance test, which is given in this Appendix, is to use different types of instruments, to properly determine the performance of the plasma spectrometer. It allows different instruments to use different operating conditions, BUT the plasma spectrometer can ultimately produce consistent results.

The whole performance test procedure is evaluated by three basic parameters: detection limit (DL), background equivalent concentration (BEC), short-term precision (RSDN).

A.2 Definition

This standard applies the following definitions: […]

A.2.1 Detection limit (DL)

When an element produces a minimum concentration signal, it can be considered to exceed any false background signal with a certain specified level; on the other hand, the element concentration produces a signal, which is three times the standard deviation of the background level value.

A.2.2 Background equivalent concentration (BEC): It is the concentration of the analyte that produces a net intensity equal to the background intensity value; it is a measure of sensitivity to a given wavelength.

A.2.3 Short-term precision (RSDN): The relative standard deviation of a series of readings of the instrument, which is obtained under the measurement conditions.

A.3 Background equivalent concentration and detection limit

Prepare 3 sets of solution, which has the concentration of the measured substances: 0 concentration level, 10 times the detection limit, 1000 times the detection limit. These solutions contain acids and matrix elements, at similar concentrations to the tested samples.

The plasma spectrometer shall be adjusted initially, according to the manufacturer's recommendations AND the laboratory's practical experience in quantitative analysis. Absorb the blank solution AND take 10 intensity readings. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 32794-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 32794-2016

$145.00