GB/T 32710.7-2016Safety requirements for environmental testing and conditioning equipment—Part 7: Climatic and environmental test chambers (English PDF)
环境试验仪器及设备安全规范 第7部分:气候环境试验箱
This is a limited preview
Buy now to download the full PDF (36 pages)
Need quotation for your management?
Get a formal quotation for GB/T 32710.7-2016 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
June 14, 2016
Implementation date
January 1, 2017
Scope
GB/T 32710.7-2016 is the English-translated version of 环境试验仪器及设备安全规范 第7部分:气候环境试验箱.
GB/T 32710.7-2016 is the Chinese standard "Safety requirements for environmental testing and conditioning equipment—Part 7: Climatic and environmental test chambers".
Its scope clause reads: GB/T 32710 this part of the provisions of the measurement, control and laboratory with the wet test chamber, salt spray test chamber, mildew test chamber, low temperature Test chamber, high and low temperature and low pressure test chamber, high temperature and low pressure test chamber, high and low temperature test chamber, high temperature test chamber, low pressure test chamber and xenon arc lamp Weather resistance and electrical burns, mechanical hazards, flame spread out of the device, excessive temperature, fluid and fluid pressure, (Including lasers, sound pressure and ultrasonic pressure), release of gas, explosion and implosion, and biological and chemical hazards. but not Including the reliability, performance or other characteristics of the equipment independent of safety, the validity of the shipping package, the EMC requirements, the Fried environmental protection measures, maintenance (repair), maintenance (repair) personnel protection.
Note 1. The working temperature range of the climate and environment test chamber can be lower and/or higher than the ambient temperature. As a cold source, it can be from air and in air Heat is absorbed in the product, as a heat source, you can air and the sample in the air to apply heat.
This part applies to the measurement, control and laboratory use of hot and humid test chamber, salt spray test chamber, mildew test chamber, low temperature test chamber, high and low temperature Low pressure chamber, high temperature and low pressure test chamber, high and low temperature test chamber, high temperature test chamber, low pressure test chamber and xenon arc lamp weather resistance test Box and so on.
Note 2. Such equipment and equipment may be probing chamber, may be a walk-in test chamber, it may be combined with vibration, shock and other comprehensive test chamber. Its clauses include normative reference documents.
Found what you need?
Document preview — GB/T 32710.7-2016
National Standard of the People's Republic of China
- ICS
- 19.040
- Classification
- N 61
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 normative reference document
- 3 Terms and definitions
- 4 Test
- 5 signs and documents
- 6 anti-shock
- 7 Mechanical hazards
- 8 Resistance to mechanical shock and impact
- 9 to prevent the spread of flame
- 10 Equipment temperature limits and heat resistance
- 11 Risk of fluid protection
- 12 Radiation protection (including laser source), sound pressure and ultrasonic pressure
- 13 Protection against release of gas, explosion and implosion
- 14 components
1 Scope
GB/T 32710 this part of the provisions of the measurement, control and laboratory with the wet test chamber, salt spray test chamber, mildew test chamber, low temperature
Test chamber, high and low temperature and low pressure test chamber, high temperature and low pressure test chamber, high and low temperature test chamber, high temperature test chamber, low pressure test chamber and xenon arc lamp
Weather resistance and electrical burns, mechanical hazards, flame spread out of the device, excessive temperature, fluid and fluid pressure, (Including lasers, sound pressure and ultrasonic pressure), release of gas, explosion and implosion, and biological and chemical hazards. but not
Including the reliability, performance or other characteristics of the equipment independent of safety, the validity of the shipping package, the EMC requirements, the
Fried environmental protection measures, maintenance (repair), maintenance (repair) personnel protection.
Note 1. The working temperature range of the climate and environment test chamber can be lower and/or higher than the ambient temperature. As a cold source, it can be from air and in air
Heat is absorbed in the product, as a heat source, you can air and the sample in the air to apply heat.
This part applies to the measurement, control and laboratory use of hot and humid test chamber, salt spray test chamber, mildew test chamber, low temperature test chamber, high and low temperature
Low pressure chamber, high temperature and low pressure test chamber, high and low temperature test chamber, high temperature test chamber, low pressure test chamber and xenon arc lamp weather resistance test
Box and so on.
Note 2. Such equipment and equipment may be probing chamber, may be a walk-in test chamber, it may be combined with vibration, shock and other comprehensive test chamber.
2 normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 2423.1-2008 Environmental testing for electric and electronic products - Part 2. Test methods - Test A. Low temperature
GB/T 2423.2-2008 Environmental testing for electric and electronic products - Part 2. Test methods - Test B. High temperature
GB/T 2423.3-2006 Environmental testing for electric and electronic products - Part 2. Test methods - Test Cab. constant damp heat test
GB/T 2423.16-2008 Environmental testing for electric and electronic products - Part 2. Test methods - Test J and Guideline.
GB/T 2423.17-2008 Environmental testing for electric and electronic products - Part 2. Test methods Test Ka. Salt mist
GB/T 2423.18-2012 Environmental tests - Part 2. Test methods Test Kb. Salt mist, alternating (sodium chloride solution)
GB/T 2423.21-2008 Environmental testing for electric and electronic products - Part 2. Test methods - Test M. Low pressure
GB/T 2423.24-2013 Environmental tests - Part 2. Test methods - Test Sa. Simulated solar radiation on the ground and its test
Guidance
GB 4208-2008 enclosure protection class (IP code)
Safety of household and similar electrical appliances - Part 1. General requirements GB 4706.1-2005
GB 4706.13-2014 Particular requirements for safety and refrigerating appliances for household and similar electrical appliances, ice cream machines and ice machines
GB 4706.17-2010 Safety of household and similar electrical appliances - Particular requirements for compressors
GB 4706.71-2008 Safety and water supply installations for household and similar electrical appliances - Particular requirements for fixed circulation pumps
GB 4706.89-2008 Safety of household and similar electrical appliances Industrial and commercial high pressure cleaners and steam cleaners
Claim
GB 4793.1-2007 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1. General requirements
Information technology - Equipment safety - Part 1. Generic requirements GB 4943.1-2011 […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 36 pages — is available in the English PDF.
Similar standards
How to Download GB/T 32710.7-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 32710.8-2016 — Safety requirements for environmental testing and conditioning equipment—Part 8: Refrigerated incubators
GB/T 32710.6-2016 — Safety requirements for environmental testing and conditioning equipment—Part 6: Climatic chambers for biological application
GB/T 32710.9-2016 — Safety requirements for environmental testing and conditioning equipment—Part 9: Electric heating incubators
Secure payment via Stripe
Payments accepted
GB/T 32710.7-2016
$560.00