GB/T 32580.302-2016Railway applications -- Fixed installations -- Particular requirements for a.c. switchgear -- Part 3-2: Measurement, control and protection devices for specific use in a.c. traction systems -- Single-phase current transformers (English PDF)
轨道交通 地面装置 交流开关设备的特殊要求 第3-2部分:交流牵引系统专用测量、控制和保护装置 单相电流互感器
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for GB/T 32580.302-2016 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Level / Type
National · Recommended
Issue date
April 25, 2016
Implementation date
November 1, 2016
Scope
GB/T 32580.302-2016 is the English-translated version of 轨道交通 地面装置 交流开关设备的特殊要求 第3-2部分:交流牵引系统专用测量、控制和保护装置 单相电流互感器.
GB/T 32580.302-2016 — This part of GB/T 32580 specifies the operating conditions, characteristics and applications of single-phase current transformers ("current transformers") Valuation and design requirements, primary short-circuit conditions, special design and structural characteristics.
This part applies to the electrified railway power supply system with nominal voltage of 25kV, 50kV and frequency of 50Hz. Electrical measurement and protection of the current transformer.
Found what you need?
Document preview — GB/T 32580.302-2016
National Standard of the People's Republic of China
- ICS
- 29.280
- Classification
- S 81
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Contents
- Preface
- 1 Scope
- 2 Normative reference document
- 3 Terms and definitions
- 4 Working conditions
- 5 Features and Applications
- 6 Rating and design requirements
- 7 Primary short circuit condition
Foreword
GB/T 32580 "Special requirements for AC switchgear for rail transit equipment" is divided into the following sections.
- Part 1. Single-phase circuit breakers with Un greater than 1 kV;
- Part 2. Single - phase disconnectors with Un greater than 1 kV, earthing switches and load switches;
- Part 3-1. Guidance on the application of measurement, control and protection devices for AC traction systems;
- Part 3-2. Special measurement, control and protection devices for AC traction systems - Single - phase current transformers;
Part 3-3. Special measurement, control and protection devices for AC traction systems Single phase inductive voltage transformers.
This part is part 3-2 of GB/T 32580.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This section uses the re-drafting method to modify the use of IEC 62505-3-2.:2009 "Rail Transit Ground Equipment AC Switchgear Special requirements - Part 3-2. Single - phase current transformers for the measurement, control and protection of AC traction systems.
The technical differences between this part and IEC 62505-3-2.:2009 are given in Appendix A.
This section makes the following editorial changes.
--- increase 8.1 "general" to eliminate the suspension section;
- Increased Information Appendix A, describing the technical differences between this and the original;
--- delete the original reference.
This section is made by the National Railway Administration.
This part is headed by the National Technical Committee for Standardization of Electrical Equipment and Systems (SAC/TC278).
This part of the main drafting unit. China Railway Fourth Survey and Design Institute Group Co., Ltd.
This part participates in the drafting unit. Railway Third Survey and Design Institute Group Co., Ltd., China Railway Electrification Survey and Design Institute Co., Ltd.
This part of the main drafters. Li Jinjun, Zhang Huazhi.
This part participates in the drafters. Zhu Jiang, Tian Shengli, Chen Xingqiang, Ye Chaorong.
Rail transit ground equipment AC switchgear special requirements Part 3-2. AC traction system for special measurement, Control and protection devices Single-phase current transformers
1 Scope
This part of GB/T 32580 specifies the operating conditions, characteristics and applications of single-phase current transformers ("current transformers") Valuation and design requirements, primary short-circuit conditions, special design and structural characteristics.
This part applies to the electrified railway power supply system with nominal voltage of 25kV, 50kV and frequency of 50Hz. Electrical measurement and protection of the current transformer.
2 Normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 1402-2010 Rail Transit Traction Power Supply System Voltage (IEC 60850.:2007, MOD) GB 4208-2008 enclosure protection class (IP code) (IEC 60529.:2001, IDT) GB 20840.2-2014 Transformers - Part 2. Supplementary technical requirements for current transformers (IEC 61869-2.:2012, MOD) GB/T 24338 (all parts) Rail traffic Electromagnetic compatibility (IEC 62236) GB/T 32580.1-2016 Particular requirements for AC switchgear for terrestrial equipment for rail transit - Part 1. Un greater than 1kV single-phase circuit breaker (IEC 62505-1.:2009, MOD)
3 Terms and definitions
The terms and definitions defined in GB 20840.2-2014 and GB/T 32580.1-2016 apply to this document.
4 Working conditions
The equipment described in this part is installed on the circuit breaker specified in GB/T 32580.1-2016, so the work of GB/T 32580.1-2016 the conditions apply to this section. If the current transformer is installed separately with the switch, the operating conditions of the switch are applicable to this section.
5 Features and applications
Current transformers should meet.
a) Installed inside the circuit breaker specified in GB/T 32580.1-2016 or installed in the special casing of the circuit breaker.
Technical requirements and the structural and test requirements of GB/T 32580.1-2016 (if applicable);
b) When installed on a separate stand, the technical requirements of this part apply.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
How to Download GB/T 32580.302-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 32580.1-2026 — Railway applications - Fixed installations - High voltage AC switchgear and transformers - Part 1: Circuit-breakers
GB/T 32580.2-2026 — Railway applications - Fixed installations - High voltage AC switchgear and transformers - Part 2: Disconnectors, earthing switches and switches
GB/T 32580.3-2026 — Railway applications - Fixed installations - High voltage AC switchgear and transformers - Part 3: Current transformers
Secure payment via Stripe
Payments accepted
GB/T 32580.302-2016
$85.00