Valid

GB/T 32514.4-2016Resistance welding -- Welding current measurement for resistance welding -- Part 4: Calibration system (English PDF)

电阻焊 焊接电流的测量 第4部分:校准系统

Preview PDF

This is a limited preview

Buy now to download the full PDF (16 pages)

Need quotation for your management?

Get a formal quotation for GB/T 32514.4-2016 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Level / Type

National · Recommended

Issue date

February 24, 2016

Implementation date

September 1, 2016

Scope

GB/T 32514.4-2016 is the English-translated version of 电阻焊 焊接电流的测量 第4部分:校准系统.

GB/T 32514.4-2016 — This part of GB/T 32514 specifies the use of resistance welding current measurement in single-phase alternating current (50Hz or 60Hz) or DC Measurement system for current measurement systems, current sensors, welding current meters, and monitoring devices with current sensors and calibration procedures. The calibration procedure applies to a welding current range of 0.5kA to 25kA.

Found what you need?

Document preview — GB/T 32514.4-2016

National Standard of the People's Republic of China

ICS
25.160.30
Classification
J 64

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Contents

  • Preface
  • 1 Scope
  • 2 Normative reference document
  • 3 Terms and definitions
  • 4 The structure of the calibration system
  • 4.1 Reference welding current measurement system
  • 4.2 Test device
  • 4.3 Basic functions required for calibration of welding current measurement system
  • 4.4 Basic functions required for current sensor calibration
  • 4.5 Basic functions required for calibration of welding current measuring instrument without sensor
  • 5 Environmental conditions
  • 6 Calibration requirements
  • 6.1 Baseline welding current measurement system
  • 6.2 Reference current sensor
  • 6.3 Data acquisition equipment
  • 6.4 Test stand and power supply
  • 7 Test Report
  • 7.1 Welding current measurement system calibration test report
  • 7.2 Current sensor calibration test report
  • 7.3 Calibration test report of welding current measuring instrument without sensor
  • 8 Test procedure
  • 8.1 Overview
  • 8.2 Calibration of welding current measurement system
  • 8.3 Calibration of current sensors
  • 8.4 Calibration of welding current measuring instrument without sensor
  • 8.5 Special calibration situation
  • Appendix A (informative) Measuring device
  • Appendix B (informative) Contents of the project to be recorded or archived as a calibration reference document
  • Appendix C (informative) Test Report Example

Foreword

GB/T 32514 "resistance welding current measurement" is divided into five parts.

- Part 1. Measurement guidelines;

Part 2. welding current measuring instrument with current sensing coil;

Part 3. Current sensing coils;

- Part 4. Calibration system;

Part 5. Confirmation of welding current measurement systems.

This part is part 4 of GB/T 32514.

This part is drafted in accordance with the rules given in GB/T 1.1-2009.

This part uses the translation method equivalent to ISO 17657-4.:2005 "Measurement of resistance welding current Part 4. Calibration system".

And the normative reference in this standard international documents are consistent with the relationship between China's documents are as follows.

GB/T 8366-2004 Mechanical and electrical requirements for solder resist welding machines (ISO 669.:2000, MOD);

Measurement of welding current for resistance welding - Part 2. Welding current measurement with current - induced coil GB/T 32514.2-2016 (ISO 17657-2.:2005, IDT).

This part is made by China Electrical Equipment Industry Association.

This part of the National Welding Technology Standardization Technical Committee (SAC/TC70) centralized.

This part of the drafting unit. Chengdu tripartite Electric Co., Ltd., Tian Tian Miaji Trade (Shanghai) Co., Ltd., Chengdu Institute of welding machine, deep Shenzhen Peng Yu Wei Technology Co., Ltd., Zhejiang Ken was Electrical Co., Ltd., Tianjin seven high-tech Co., Ltd.

This part of the main drafters. Du Wu, Zong Yang, Wang Hui, Liu Xingwei, Zhu Xuanhui, Yang Weiguo.

Measurement of welding current of resistance welding Part 4. Calibration system

1 Scope

This part of GB/T 32514 specifies the use of resistance welding current measurement in single-phase alternating current (50Hz or 60Hz) or DC Measurement system for current measurement systems, current sensors, welding current meters, and monitoring devices with current sensors and calibration procedures.

The calibration procedure applies to a welding current range of 0.5kA to 25kA.

2 Normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document.

GB/T 32514.3-2016 Resistance welding current measurement - Part 3. Current sensing coils (ISO 17657-3.:2005, IDT) ISO 669 resistance welding resistance machine mechanical and electrical requirements (Resistancewelding-Resistanceweldingequip-ment-mechanicalandelectricalrequirements ISO 17657-2 Resistance welding current measurement - Part 2. Welding current measuring instrument with current sensing coil (Resistancewelding-Weldingcurrentmeasurementforresistancewelding-Part 2. Weldingcurrent meterwithcurrentsensingcoil)

3 Terms and definitions

The following terms and definitions apply to this document.

Test (current) sensor test (current) sensor the current sensor to be calibrated.

Reference (current) sensor reference (current) sensor A high-precision condition has been calibrated for the current sensor to calibrate the current sensor.

Test welding current measuring instrument testweldingcurrentmeter the welding current meter to be calibrated.

No sense of shunt non-inductiveshunt with a very low inductance, with high accuracy and low resistance of the shunt.

Analog-to-digital converter;

Means for converting the analog input signal into a digital signal.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.

How to Download GB/T 32514.4-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
16 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 32514.4-2016