GB/T 32115-2015Determination of ethylene glycol and diethylene glycol in oral care products (English PDF)

口腔护理产品中乙二醇与二甘醇的测定方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 32115-2015 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

October 13, 2015

Implementation date

May 1, 2016

Scope

GB/T 32115-2015 is the English-translated version of 口腔护理产品中乙二醇与二甘醇的测定方法.

GB/T 32115-2015 specifies the principle, the reagents and materials, the instruments and equipment, the analytical procedures, the result calculation, the detection limits and the allowable difference for the determination of ethylene glycol and diethylene glycol in oral care products.

Clause 1 states that the standard is applicable to the determination of the ethylene glycol and diethylene glycol contents in oral care products, and that in this standard the detection limit of each of the two is 20 mg/kg.

The table of contents runs from clause 1, Scope, and clause 2, Normative References, which cites GB/T 6682, through clause 3, Principle, clause 4, Reagents and Materials, clause 5, Instruments and Equipment, clause 6, Analytical Procedures, clause 7, Result Calculation, clause 8, Detection Limits, and clause 9, Allowable Difference, to Appendix A, an informative gas chromatogram of the standard samples, and Appendix B, an informative confirmatory test.

Under clause 3 the two glycols are extracted from the sample with methanol by the ultrasonic method and filtered, then separated and determined on a gas chromatograph with a hydrogen flame ionization detector, identified qualitatively by retention time, quantified by the external standard method and confirmed by chromatography-mass spectrometry.

Clause 4 requires analytically pure reagents and Grade-1 water as specified in GB/T 6682, and lists chromatographically pure methanol, sodium chloride and standard samples of ethylene glycol and of diethylene glycol.

Clause 6 sets out the sample preparation, in which 2 g of sample accurate to 0.01 g is weighed into a 50 mL stoppered graduated tube with 20.0 mL of methanol, vortex mixed for one minute, ultrasonically extracted for 20 minutes and filtered through a membrane, and then the reference conditions of the gas chromatograph, an HP-INNOWAX quartz capillary column 30 m long with an inner diameter of 0.25 mm or one of equivalent performance, high-purity nitrogen carrier gas at a constant flow of 1.0 mL/min, a programmed temperature rise from 40 °C to 250 °C, an inlet at 240 °C, a detector at 250 °C and split injection at a ratio of 10:1, followed by the standard working curve, the quantitative analysis, the blank test and the parallel test.

Clause 7 gives the formula for the contents in mg/kg from the concentration in the determination solution, the final volume, the dilution factor and the mass of the sample, with a note that the blank value must be subtracted and the result reported as the arithmetic mean of parallel determinations.

Appendix B lists the gas chromatography and mass spectrometry conditions for confirming positive results, including high-purity helium carrier gas, split injection at 5:1, an interface temperature of 250 °C, electron impact ionization at 70 eV and a full scan from 10 amu to 150 amu.

The front page of this English version states that the standard was issued on 13 October 2015 and implemented on 1 May 2016.

Found what you need?

Document preview — GB/T 32115-2015

National Standard of the People's Republic of China

ICS
71.100.40
Classification
Y 43

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative References4
  • 3 Principle4
  • 4 Reagents and Materials4
  • 5 Instruments and Equipment5
  • 6 Analytical Procedures5
  • 7 Result Calculation7
  • 8 Detection Limits8
  • 9 Allowable Difference8
  • Appendix A (informative) Gas Chromatogram of Standard Samples9
  • Appendix B (informative) Confirmatory Test10

1 Scope

This Standard specifies the principle, reagents and materials, instruments and equipment, analytical procedures, result calculation, detection limits and allowable difference for the determination of ethylene glycol and diethylene glycol in oral care products.

This Standard is applicable to the determination of ethylene glycol and diethylene glycol contents in oral care products.

In this Standard, the detection limits of ethylene glycol and diethylene glycol are both 20 mg/kg.

2 Normative References

The following documents are indispensable to the application of this document. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document.

GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods

3 Principle

Ethylene glycol and diethylene glycol in oral care products are extracted with methanol by ultrasonic method, filtered, then, separated and determined by gas chromatograph-hydrogen flame ionization detector, qualitatively determined by retention time, quantitatively determined by external standard method, and confirmed by chromatography-mass spectrometry.

4 Reagents and Materials

4.1 Unless otherwise specified, all reagents used are analytically pure, and water is Grade-1 water as specified in GB/T 6682.

4.2 Methanol: chromatographically pure.

4.3 Sodium chloride.

4.4 Ethylene glycol standard sample: purity >= 99%. For relevant information, see Table 1.

4.5 Diethylene glycol standard sample: purity >= 99%. For relevant information, see Table 1.

6 Analytical Procedures

6.1 Sample Preparation

Weigh-take 2 g (accurate to 0.01 g) of sample into a 50 mL graduated tube with a stopper, add 20.0 mL of methanol (4.2), add 2.0 g of sodium chloride (4.3), and perform vortex mixing for 1 minute. Then, perform ultrasonic extraction for 20 minutes, let it stand, filter the supernatant through the filter membrane (4.8) and reserve it for testing.

6.1.3 Powder

Weigh-take 2 g (accurate to 0.01 g) of sample into a 50 mL graduated tube with a stopper, add 20.0 mL of methanol (4.2), and perform vortex mixing for 1 minute. Then, perform ultrasonic extraction for 20 minutes, let it stand, filter the supernatant through the filter membrane (4.8) and reserve it for testing.

6.2 Determination

6.2.1 Reference conditions of gas chromatography

6.2.1.1 Chromatographic column: HP-INNOWAX quartz capillary chromatographic column, 30 m x 0.25 mm (inner diameter) x 0.25 µm, or one with equivalent performance.

6.2.1.2 Carrier gas: high-purity nitrogen, purity > 99.99%

6.2.1.3 Flow rate: 1.0 mL/min, constant-flow mode

6.2.1.4 Use programmed temperature rise: the initial column temperature is 40 °C, maintain it for 1 minute, then, at a rate of 10 °C/min, raise the temperature to 150 °C and maintain it for 10 minutes, then, at a rate of 30 °C/min, raise the temperature to 250 °C and maintain it for 5 minutes.

6.2.1.5 Inlet temperature: 240 °C

6.2.1.6 Detector temperature: 250 °C

6.2.1.7 Sample injection mode: split injection, with a split ratio of 10: 1.

6.2.2 Drawing of standard working curve

Determine a series of ethylene glycol and diethylene glycol mixed standard working solutions (4.7) with a concentration of 10.0 µg/mL, 50.0 µg/mL, 100.0 µg/mL, 200.0 µg/mL and 500.0 µg/mL in accordance with the reference conditions of gas chromatography (6.2.1). By taking the peak area as the y-coordinate and the concentration as the x-coordinate, draw the standard working curve.

For the gas chromatogram of standard samples of ethylene glycol and diethylene glycol, please refer to Figure A.1 of Appendix A.

6.2.3 Quantitative analysis

Determine the sample solution obtained through sample preparation (6.1) in accordance with the reference conditions of gas chromatography (6.2.1) and record the retention time and peak area of the chromatographic peak. The corresponding concentrations of ethylene glycol and diethylene glycol can be calculated through the peak area of the chromatographic peak from the standard working curve. The response values of ethylene glycol and diethylene glycol in the sample to be determined shall be within the linear range of the standard working curve. If they exceed the linear range, then, sample injection and analysis shall be performed after dilution.

6.2.4 Qualitative confirmation

For samples with positive results during the determination process, it is recommended to confirm with gas chromatography-mass spectrometry, see Appendix B.

6.3 Blank Test

Except that the sample is not weighed, in accordance with the sample preparation (6.1) steps and determination (6.2) conditions, carry out the blank test.

6.4 Parallel Test

In accordance with the sample preparation (6.1) steps and determination (6.2) conditions, conduct parallel test and determination on the same sample.

7 Result Calculation

The ethylene glycol and diethylene glycol contents (mg/kg) in oral care products shall be calculated in accordance with Formula (1):

Where, X---the ethylene glycol and diethylene glycol contents in oral care products, expressed in (mg/kg); c---the ethylene glycol and diethylene glycol concentrations in the sample determination solution, expressed in (µg/mL);

V---the final constant volume of the sample solution, expressed in (mL); k---the dilution factor; m---the mass of the sample, expressed in (g).

NOTE: the blank value must be subtracted from the calculation result. The determination result is expressed as the arithmetic mean of parallel determinations and rounded to the nearest

Appendix B (informative) Confirmatory Test

B.1 Reference Conditions of Gas Chromatography

Chromatographic column: HP-INNOWAX quartz capillary chromatographic column, 30 m x 0.25 mm (inner diameter) x 0.25 µm, or one with equivalent performance. Carrier gas: high-purity helium, purity > 99.99%. Flow rate: 1.0 mL/min, constant-flow mode.

Use programmed temperature rise: the initial column temperature is 40 °C, maintain it for 1 minute, then, at a rate of 10 °C/min, raise the temperature to 150 °C and maintain it for 10 minutes, then, at a rate of 30 °C/min, raise the temperature to 250 °C and maintain it for 5 minutes. Inlet temperature: 240 °C. Injection volume: 1 µL. Sample injection mode: split injection. Split ratio: 5: 1. Chromatography-mass spectrometry interface temperature: 250 °C.

B.2 Reference Conditions of Mass Spectrometry

Ionization mode: electron impact source (EI). Ionization energy: 70 eV. Solvent delay: 5 min.

Determination mode: full scan mode, with a scanning range of 10 amu ~ 150 amu.

The quantitative ion, qualitative ion and ion abundance ratio are shown in Table B.1. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 32115-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included