Valid

GB/T 30966.6-2022Wind energy generation systems - Communications for monitoring and control of wind power plants - Part 6: Logical node classes and data classes for condition monitoring (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (39 pages)

Need quotation for your management?

Get a formal quotation for GB/T 30966.6-2022 in 30 minutes.

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

October 12, 2022

Implementation date

October 12, 2022

Scope

GB/T 30966.6-2022 (Wind energy generation systems - Communications for monitoring and control of wind power plants - Part 6: Logical node classes and data classes for condition monitoring) is available as an English-translated PDF.

GB/T 30966.6-2022 is Part 6 of the Chinese series on communications for the monitoring and control of wind power plants, and it covers condition monitoring.

It specifies the information models used for condition monitoring of wind turbines and the exchange of the data values that belong to them, together with the abbreviations, the coordinate system directions and angles, and the concept of the operating state bin.

It defines the logical node WCON, the logical nodes reused from GB/T 30966.2 and the common data classes CMB, CMM, SVA and CMVA, with the full attribute definitions of CMM.

Informative annexes list recommended measurement type values, explain tag naming and give bin and application examples. Identical to IEC 61400-25-6:2016, it replaces GB/T 30966.6-2015, was issued on 12 October 2022 and has applied since the same day.

Found what you need?

Document preview — GB/T 30966.6-2022

National Standard of the People's Republic of China

ICS
27.180
Classification
F 11
Replacing
GB/T 30966.6-2015

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Abbreviations
  • 5 General
  • 5.1 Overview
  • 5.2 Condition monitoring information model
  • 5.3 The agreed direction and angle of the coordinate system
  • 5.4 Concept of running status bin
  • 6 Wind turbine condition monitoring logic node
  • 6.1 General
  • 6.2 Logical node from GB/T 30966.2
  • 6.3 Wind turbine condition monitoring logical node WCON
  • 7 Common data types for condition monitoring of wind turbines
  • 7.1 Overview
  • 7.2 Common data classes defined in GB/T 30966.2
  • 7.3 Data attribute contains conditions
  • 7.4 Common data class attribute name semantics
  • 7.5 Condition Monitoring Chamber (CMB)
  • 7.6 Condition Monitoring Measurement (CMM)
  • 7.7 Scalar Valued Arrays (SVA)
  • 7.8 Complex Measured Value Array (CMVA)
  • 8 Common data class CMM attribute definition
  • 8.1 Overview
  • 8.2 Properties of condition monitoring measurement descriptions
  • Appendix A (informative) recommended measurement type (mxType) value
  • A.1 Overview of tag names and data names of WCON classes
  • A.2 Mapping of measurement tags to measurement types (mxType)
  • A.3 Measurement type (mxType) value
  • Appendix B (Informative) Application of Data Attributes in Condition Monitoring Measurement Description Tag Naming
  • B.1 Overview
  • B.2 Naming principles of common data class CMM data attributes
  • B.3 Example
  • Appendix C (informative) Example of condition monitoring cabin
  • C.1 Example 1: One-dimensional bin
  • C.2 Example 2: Two-dimensional bin
  • C.3 Example 3: Intersecting 2D bins
  • Appendix D (Informative) Application Example
  • D.1 Overview of Common Data Classes (CDCs) required for this document
  • D.2 How to apply data to CDC
  • D.3 How to apply the alarm
  • Reference

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules for Standardization Documents" drafting.

This document is part 6 of GB/T 30966 "Wind Turbine Wind Farm Monitoring System Communication". GB/T 30966 has The following parts have been published.

--- Part 1: Principles and models;

--- Part 2: Information model;

--- Part 3: Information exchange model;

--- Part 4: Mapping to communication protocol;

--- Part 5: Conformance testing;

--- Part 6: Logical node classes and data classes for status monitoring.

This document replaces GB/T 30966.6-2015 "Wind Turbine Wind Farm Monitoring System Communication Part 6: Status Monitoring Logical Node Classes and Data Classes for Testing", compared with GB/T 30966.6-2015, except for structural adjustments and editorial changes, the main technical changes as follows.

a) Changed the restructured data model (see 5.1, 7.1, 7.3, 7.4, 7.5, 7.6, 7.7, 7.8, 5.1, 7.1, 7.3, 7.4, 7.5, 7.6, 7.7, 7.8);

b) Delete the UFF58 format (see Chapter 9 of the 2015 edition);

c) Added reporting and logging functions for data access usage standards (see 6.2, 8.2 of the 2015 edition).

This document is equivalent to IEC 61400-25-6:2016 "Wind Turbine Generating Sets Part 25-6: Communication of Wind Farm Monitoring System Logical Node Classes and Data Classes for Condition Monitoring".

The following minimal editorial changes have been made to this document.

--- In order to coordinate with existing standards, change the name of the standard to "Wind Turbine Wind Farm Monitoring System Communication Part 6: Logical node class and data class for state monitoring";

--- Added examples and application examples of condition monitoring cabins (see Appendix C and Appendix D).

Introduction

GB/T 30966 "Wind Turbine Wind Farm Monitoring System Communication" defines the information model and information exchange of wind farm monitoring.

It is possible to switch models, thereby enabling commonality of access between different clients and servers from different manufacturers and suppliers. GB/T 30966 Mainly based on the international document IEC 61400-25, it defines the mapping of wind farm specific information, information exchange mechanism and communication protocol. At this On the one hand, IEC 61400-25 specifies detailed requirements for exchanging available information with wind farm components in a manufacturer-independent environment. These need It is required to give the definition in IEC 61400-25 or refer to other standards.

GB/T 30966 (all parts) currently consists of the following 6 parts.

--- Part 1: Principles and models. The purpose is to study the general communication between the wind farm SCADA system and the wind turbine sexual demands.

--- Part 2: Information Model. The purpose is to specify the summary description of the logical node class, the logical node class of the wind farm to the common logical node class definitions and requirements.

--- Part 3: Information exchange model. The purpose is to specify an information exchange model that can be used by clients and servers to access The content and structure of the wind farm information model defined in GB/T 30966.2.

--- Part 4: Mapping to the communication protocol. The purpose is to specify a specific mapping oriented to the protocol stack, and provide a link between the client and the remote server. Provide the required information encoding for information exchange between them.

--- Part 5: Conformance testing. The purpose is to specify the various components (such as wind turbines) and participants (such as wind turbines) in the wind farm General requirements for communication between SCADA systems), detailing standard techniques for implementing conformance testing, and deterministic Specific measurement techniques applied when parameters are available.

--- Part 6: Logical node classes and data classes for status monitoring. Its purpose is to control wind turbine or wind farm components or structures Observe the components for a period of time, evaluate the state and state changes of the components or structural parts, so as to find potential faults early signs.

Condition monitoring functions can be realized by different physical devices. Some information may be monitored by the generator set controller (TCD), others Some information may be the responsibility of other Condition Monitoring Devices (CMDs). Each participant can request to exchange data in TCD or CMD.

SCADA equipment can request to call information in TCD or CMD; CMD can also request to call TCD information within. Information exchange between participants and equipment in a wind farm requires the use of the information exchange defined in IEC 61400-25-3 Serve. A schematic illustration of the above is shown in Figure 1.

Control and condition monitoring applications in the wind power industry use the technical structure of separate devices. For this reason, the information model and information The information exchange model is based on a structure consisting of a TCD and a CMD.

The main content of the GB/T 30966.6 document is condition monitoring, which is an extension of the IEC 61400-25 series of documents.

1 Scope

This document specifies information models related to condition monitoring of wind farms and information exchange of data values related to these information models.

Note: The premise of conforming to the principles of this document is to comply with GB/T 30966.2, GB/T 30966.3 and GB/T 30966.4.

Figure 2 shows the information flow of a system that can use the condition monitoring function to complete condition maintenance. This diagram illustrates how to pass The information link centralizes and refines the data, so as to achieve the ultimate goal of state maintenance, that is, to issue work instructions to the maintenance team, and then take Corresponding measures are taken to ensure the good operation of wind farms.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 39 pages — is available in the English PDF.

How to Download GB/T 30966.6-2022

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
39 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 30966.6-2022

$530.00