GB/T 26692-2011Frequency-flick-free a.c. supplied electronic ballasts for tubular fluorescent lamps - Performance requirements (English PDF)
管形荧光灯用无频闪电子镇流器 性能要求
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for GB/T 26692-2011 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
June 16, 2011
Implementation date
December 1, 2011
Scope
GB/T 26692-2011 is the English-translated version of 管形荧光灯用无频闪电子镇流器 性能要求.
GB/T 26692-2011 — This standard specifies the high frequency operation of tubular fluorescent lamps flicker free electronic ballast performance requirements.
This standard applies to the use of the frequency of 50Hz, 60Hz AC or DC power supply, voltage 1000V or less, the operating frequency Unlike tubular fluorescent power frequency, match it should comply with GB/T 10682 and GB/T 17262 requirements.
Note 1. The test described in this standard are type tests. It does not include a single ballast during production test requirements. Note 2. For the final product, such as lamps and stand-alone control devices, has developed on adjusting the supply current harmonics and immunity of the special standard.
At this Aspect, lighting control device plays a major role. Control devices and other components shall comply with these standards.
Found what you need?
Document preview — GB/T 26692-2011
National Standard of the People's Republic of China
- ICS
- 29.140.30
- Classification
- K 71
Issued by: Standardization Administration of China
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 General notes on
- 5 Mark
- 6 3 General Information
- 7 Start Condition
- Working conditions 8
- 9 Line power factor
- 10 Supply Current
- A cathode lead 11 introduced into either the maximum current
- 12 Lamp operating current waveform
- 13 Ballasts Output current frequency
- 14 Acoustic impedance
- Experimental work under abnormal conditions 15
- Durability 16
- 17 Harmonic
- 18 Radio disturbance characteristics
- Appendix A (normative) Test
- Appendix B (normative) reference ballast
- Annex C (normative) benchmark light conditions
- Annex D (informative) product life and failure rate of 11 evaluation method
Foreword
The Standard Appendix A, Appendix B, Appendix C is normative appendix, Appendix D is an informative annex.
The standard proposed by China National Light Industry Council.
This standard by the National Standardization Technical Committee of electrical lighting (SAC/TC224) centralized.
This standard was drafted. National Electric Light Source Quality Supervision and Inspection Center (Shanghai), Beijing Lighting Research Institute, Zhongshan Op lighting Shares Limited.
1 Scope
This standard specifies the high frequency operation of tubular fluorescent lamps flicker free electronic ballast performance requirements.
This standard applies to the use of the frequency of 50Hz, 60Hz AC or DC power supply, voltage 1000V or less, the operating frequency Unlike tubular fluorescent power frequency, match it should comply with GB/T 10682 and GB/T 17262 requirements.
Note 1. The test described in this standard are type tests. It does not include a single ballast during production test requirements.
Note 2. For the final product, such as lamps and stand-alone control devices, has developed on adjusting the supply current harmonics and immunity of the special standard. At this Aspect, lighting control device plays a major role. Control devices and other components shall comply with these standards.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 2900.65 Electrotechnical terminology Lighting (GB/T 2900.65-2004, IEC 60050 (845). 1987, MOD) GB/T 10682 double-ended fluorescent lamps - Performance requirements GB/T 15144-2009 tubular fluorescent lamps with electronic ballasts Performance requirements (IEC 60929:2006, MOD) GB/T 17262 Single-capped fluorescent lamps - Performance requirements GB 17625.1 Electromagnetic Compatibility Limits for harmonic current emissions (equipment input current <=16A) (GB 17625.1-2003, IEC 61000-3-2:2001, IDT) Limits and methods of measurement of radio disturbance characteristics of GB 17743 electrical lighting and similar equipment (GB 17743-2007, CISPR15.
2005 A1.2006, IDT)
Part 1 GB 19510.1 lamp control apparatus. General and safety requirements (GB 19510.1-2009, IEC 61347-1.
2007, IDT)
Section 4 GB 19510.4 Lamp control unit. electronic ballasts for fluorescent lamps - Particular requirements (GB 19510.4-2009, IEC 61347-2-3:2006, IDT) IEC 60410 count inspection Sampling plans and procedures (Samplingplansandproceduresforinspectionbyattrib-utes)
3 Terms and Definitions
GB 19510.1 establish the following terms and definitions apply to this standard.
Start aid startingaid Start auxiliary member may be fixed in a light strip on the outer surface of the conductive member, or a lamp at appropriate intervals to maintain a sheet-shaped guide Electrical components. Start aid is usually grounded and only at one end of the lamp when sufficient work to keep the potential difference.
Ballast lumen factor balastlumenfactor when tested ballast at its rated voltage, the lamp luminous flux of the lamp and the appropriate reference ballast at its rated voltage and together
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2900.65Electrotechnical terminology - Lighting
- GB/T 2900.65-2004Electrotechnical terminology - Lighting
- GB/T 10682Double-capped fluorescent lamps -- Performance specifications
- GB/T 15144-2009AC and/or DC-supplied electronic control gear for tubular fluorescent lamps - Performance requirements
- GB/T 17262Single-capped fluorescent lamps -- Performance specification
- GB 17625.1Electromagnetic compatibility - Limits - Part 1: Limits for harmonic current emissions(equipment input current <=16 A per phase)
IEC 60050 · IEC 60929 · IEC 61000 · GB 19510.1 · GB 19510.1-2009 · IEC 61347 · IEC 60410
How to Download GB/T 26692-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 17625.1-2022 — Electromagnetic compatibility - Limits - Part 1: Limits for harmonic current emissions(equipment input current <=16 A per phase)
GB 17743-2007 — [GB/T 17743-2007] Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
GB 19510.10-2009 — Lamp controlgear -- Part 10: Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps)
Secure payment via Stripe
Payments accepted
GB/T 26692-2011
$574.00