GB/T 26237.10-2022Information technology - Biometric data interchange formats - Part 10: Hand geometry silhouette data (English PDF)
Also coversGBT26237.10-2022
Open the GB/T 26237.10-2022 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
October 14, 2022
Implementation date
May 1, 2023
Scope
GB/T 26237.10-2022 (Information technology - Biometric data interchange formats - Part 10: Hand geometry silhouette data) is available as an English-translated PDF.
GB/T 26237.10-2022 — This document specifies a data exchange format for hand contour information, and establishes the content, format and measurement of hand contour data exchange. unit. This document also specifies the compliance test methods, test assertions and elements of the test procedure for the Hand Profile Data Interchange Format. established. --- Test assertion for the structure of the hand profile data format specified in Chapter 8 (see the definition in Appendix A of GB/T 26237.1-2022 of Class A, Level 1); --- Test assertions to check internal compatibility by detecting the type of value of each field of hand contour data (see GB/T 26237.1- Category A Level 2 as defined in Appendix A of 2022); --- Informative guidance for testing the compatibility of selected coded data fields with entered biometric data (see GB/T 26237.1- Class B Level 3 as defined in Appendix A of 2022). The compliance test methods specified in this document do not involve. --- Compliance testing of the CBEFF structure required by this document; --- Compatibility test with input biometric data record (see Level 3 defined in Appendix A of GB/T 26237.1-2022); --- Testing of other characteristics of biometric products or other types of testing (such as acceptability, performance, robustness and security, etc.); --- Compliance testing of systems that do not generate data records as required by this document. This document is suitable for recording, storing and transmitting hand profile information in the field of biometric identification. This document also applies to compliance testing of hand profile data records, and to the development and use of compliance test suites.
Document preview — GB/T 26237.10-2022
National Standard of the People's Republic of China
- ICS
- 35.040
- Classification
- L 71
- Replacing
- GB/T 26237.10-2014
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents"
drafted.
This document is part 10 of GB/T 26237 "Information Technology Biometric Data Interchange Format". GB/T 26237 has
The following sections were published.
--- Part 1.Framework;
--- Part 2.Fingerprint minutiae data;
--- Part 3.Fingerprint spectral data;
--- Part 4.Fingerprint image data;
--- Part 5.Face image data;
--- Part 6.Iris image data;
--- Part 7.Signature/Signature Time Series Data;
--- Part 8.Fingerprint skeleton data;
--- Part 9.Vascular image data;
--- Part 10.Hand contour data;
--- Part 14.DNA data;
--- Part 15.Palmprint image data.
This document replaces GB/T 26237.10-2014 "Information Technology Biometric Data Interchange Format Part 10.Hand Wheel
Compared with GB/T 26237.10-2014, in addition to structural adjustment and editorial changes, the main technical changes are as follows.
a) Added the definition of the scope and applicability of the compliance test method in the scope (see Chapter 1, Chapter 1 of the.2014 edition);
b) Added two terms and definitions, "Biometric Data Exchange Record" (see 3.3) and "Tested Realization" (see 3.8);
c) Deleted the terms and definitions of "field acquisition" (see 4.7 of the.2014 edition) and "pixel" (see 4.7 of the.2014 edition);
d) Modified "Biometric data block" (see 3.1, 4.1 of the.2014 edition), "Biometric sample" (see 3.2,.2014 edition of the
4.2), "Freeman Chain Code" (see 3.6, 4.5 of the.2014 edition), Hand View Recording (see 3.9, 4.8 of the.2014 edition) and "Acquisition"
"face" (see 3.10, 4.10 of the.2014 edition) and other definitions of 7 terms;
e) 3 abbreviations such as "BDIR", "IUT" and "ppcm" were added (see Chapter 4);
f) Changed the compliance requirements (see Chapter 5, Chapter 2 of the.2014 edition);
g) Added requirement for owner identifier in CBEFF format (see 6.3).
This document is modified using ISO /IEC 19794-10.2007 "Information Technology Biometric Data Interchange Format Part 10.
Hand Profile Data".
Compared with ISO /IEC 19794-10.2007, this document has more structural adjustments. Comparison of the structure number changes of the two files
See Appendix A for a list.
Compared with ISO /IEC 19794-10.2007, this document has many technical differences, in the outer margin of the clauses involved
Marked with a vertical single line (|). These technical differences and their reasons are as follows.
--- Added the definition of the scope and applicability of the compliance test method in the scope (see Chapter 1);
--- Delete the term "living collection" of ISO /IEC 19794-10.2007, because the term does not appear in this document;
--- Deleted the term "pixel" in ISO /IEC 19794-10.2007, which is a common term and does not need to be defined repeatedly;
--- Added the terms "biometric data exchange record" (see 3.3) and "tested implementation" (see 3.8) to facilitate the understanding of this document.
understand;
--- Changed the term name "data resolution" (see 3.7), the original name is "image resolution", because "image resolution" is not in this article
appears in the file, what appears is "Data Resolution";
--- Changed the compliance requirements (see Chapter 5);
--- Changed the content of "Note" in 7.2 and "Note" in 8.3.3 to be normative clauses, because compliance with these clauses is required
test;
--- Added normatively cited GB/T 1988 (see 8.1, 8.2.2 and 8.2.3); replaced with normatively cited GB/T 28826.1
ISO /IEC 19785-1 (see 6.3); ISO /IEC 19784-1 (see 6.3) replaced by normative reference GB/T 30267.1
8.3.1 and 8.3.8);
---Changed "shooting device X coordinate", "shooting device Y coordinate", "target X coordinate", "target Y coordinate" and "target Z coordinate" in Table 2
"X coordinate of the starting point of the hand contour" and "Y coordinate of the starting point of the hand contour", because related to this document
Inconsistencies in the requirements of the paragraph are corrected to eliminate ambiguity;
--- Added "compliance test method" (see Appendix B).
The following editorial changes have been made to this document.
--- Added informative Appendix E "Guidelines for Level 3B Compliance Testing".
Please note that some content of this document may be patented. The issuing agency of this document assumes no responsibility for identifying patents.
Introduction
GB/T 26237 "Information Technology Biometric Data Interchange Format" supports the exchange between biometric applications and systems
Interoperability and data exchange, the biometric data exchange format is specified for different biometric identification modalities, conforming to the
Parties to the Biometric Data Interchange Format specified in GB/T 26237 are able to decode each other's biometric data, thereby
Meet the complexity requirements of applying biometrics to a wide variety of applications.
GB/T 26237 "Information Technology Biometric Data Interchange Format" is proposed to consist of 15 parts.
--- Part 1.Framework. The purpose is to specify the general content, meaning, representation and conformity of biometric data formats
testing method.
--- Part 2.Fingerprint minutiae data. The purpose is to specify a data record exchange format and compliance test for fingerprint minutiae points.
try method.
--- Part 3.Fingerprint spectral data. The purpose is to specify a data record exchange format and compliance test for fingerprint profiles
method.
--- Part 4.Fingerprint image data. The purpose is to specify a data record exchange format and compliance test of fingerprint images
method.
--- Part 5.Face image data. The purpose is to specify a data record exchange format and compliance test for face images
method.
--- Part 6.Iris image data. The purpose is to specify a data record exchange format and compliance test for iris images
method.
--- Part 7.Signature/Signature time series data. The purpose is to specify a data record exchange format for signature/signature data
and compliance testing methods.
--- Part 8.Fingerprint skeleton data. The purpose is to specify a data record exchange format and conformity test of a fingerprint skeleton
method.
--- Part 9.Vascular image data. The purpose is to specify a data record exchange format and compliance test for human blood vessel images.
try method.
--- Part 10.Hand contour data. The purpose is to specify a data record exchange format and compliance test for hand contour data.
try method.
--- Part 11.Processed signature/signature dynamic data. The purpose is to specify a processed signature/signature dynamic data
Data record exchange formats and compliance testing methods.
--- Part 12.Face shape characteristic data. The purpose is to specify a data record exchange format and compliance test for a face shape characteristic
method.
--- Part 13.Sound data. The purpose is to specify a sound data recording exchange format and compliance test method.
--- Part 14.DNA data. The purpose is to specify a DNA data record exchange format and compliance testing method.
--- Part 15.Palmprint image data. The purpose is to specify a data record exchange format and compliance test for human palmprint images.
try method.
This document defines a hand profile data record exchange format consisting of mandatory and optional options, including data acquisition parameters.
Number, standardized placement of hands, and supplier-specific information to support a variety of automated equipment and systems for identification or verification based on hand information
Systematic information exchange. Information formatted in accordance with this document may be recorded on machine-readable media or transmitted via data communications between systems.
This document also establishes compliance testing methods for testing implementations that claim compliance with this document.
In addition, this document provides best practices, data examples, and testing guidelines for hand contour data collection.
Information Technology Biometric Data Interchange Format
Part 10.Hand Profile Data
1 Scope
This document specifies a data exchange format for hand contour information, and establishes the content, format and measurement of hand contour data exchange.
unit.
This document also specifies the compliance test methods, test assertions and elements of the test procedure for the Hand Profile Data Interchange Format. established.
--- Test assertion for the structure of the hand profile data format specified in Chapter 8 (see the definition in Appendix A of GB/T 26237.1-2022
of Class A, Level 1);
--- Test assertions to check internal compatibility by detecting the type of value of each field of hand contour data (see GB/T 26237.1-
Category A Level 2 as defined in Appendix A of 2022);
--- Informative guidance for testing the compatibility of selected coded data fields with entered biometric data (see GB/T 26237.1-
Class B Level 3 as defined in Appendix A of 2022).
The compliance test methods specified in this document do not involve.
--- Compliance testing of the CBEFF structure required by this document;
--- Compatibility test with input biometric data record (see Level 3 defined in Appendix A of GB/T 26237.1-2022);
--- Testing of other characteristics of biometric products or other types of testing (such as acceptability, performance, robustness and security, etc.);
--- Compliance testing of systems that do not generate data records as required by this document.
This document is suitable for recording, storing and transmitting hand profile information in the field of biometric identification.
This document also applies to compliance testing of hand profile data records, and to the development and use of compliance test suites.
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations
documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to
this document.
GB/T 1988 Seven-bit coded character set for information exchange in information technology (GB/T 1988-1998, eqvISO /IEC 646.
1991)
GB/T 28826.1 Information Technology Common Biometrics Exchange Format Framework Part 1.Specification of Data Elements
(GB/T 28826.1-2012, ISO /IEC 19785-1.2006, MOD)
GB/T 30267.1 Information Technology Biometric Identification Application Program Interface Part 1.BioAPI Specification (GB/T 30267.1-
2013, ISO /IEC 19784-1.2006, IDT)
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
biometricdatablock
A data block with a defined format that contains one or more biometric samples or biometric templates.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 28826.1Information technology -- Common biometric exchange formats framework -- Part 1: Data element specification
- GB/T 28826.1-2012Information technology -- Common biometric exchange formats framework -- Part 1: Data element specification
GB/T 1988 · GB/T 1988-1998 · IEC 646 · IEC 19785 · GB/T 30267.1 · IEC 19784
How to Buy GB/T 26237.10-2022
- 1Add to cart. Click the "Buy GB/T 26237.10-2022" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 19882.211-2010 — Automatic meter reading system - Part 211: Distribution line carrier meter reading system - System requirements
GB/T 19882.212-2012 — Automatic meter reading system - Part 212: Distribution line carrier meter reading system - DLC Concentrator
GB/T 19882.213-2012 — Automatic meter reading system - Part 213: Distribution line carrier meter reading system - DLC Acquisition unit
Secure payment via Stripe
Payments accepted
GB/T 26237.10-2022
$485.00