GB/T 25934.2-2010Methods for the chemical analysis of high-purity gold - Part 2: Determination of impurity elements by inductively coupled plasma mass spectrometry with standard addition correction and internal standardisation (English PDF)
高纯金化学分析方法 第2部分:ICP-MS-标准加入校正-内标法 测定杂质元素的含量
Open the GB/T 25934.2-2010 preview as PDF
This is a limited preview
Buy now to download the full PDF (15 pages)
Issued by
General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the PRC
Level / Type
National · Recommended
Issue date
December 23, 2010
Implementation date
September 1, 2011
Scope
GB/T 25934.2-2010 is the English-translated version of 高纯金化学分析方法 第2部分:ICP-MS-标准加入校正-内标法 测定杂质元素的含量.
China's national method for determining the impurity elements in high-purity gold by inductively coupled plasma mass spectrometry using standard addition correction with an internal standard. It is Part 2 of GB/T 25934 and specifies the principle, the reagents, the apparatus, the procedure and the precision. Where Part 1 removes the gold matrix before measuring, this part keeps it and corrects for it. That is the harder route analytically but the more useful one in practice, because every separation risks losing an analyte and because mass spectrometry is sensitive enough to work at these concentrations directly - the detection limits are one to two orders of magnitude below what the emission method reaches, which is what allows gold of 99.999 per cent and above to be characterised at all. The price is that the matrix effects are severe. A solution containing percent-level gold suppresses the ion signal of everything else, and the suppression is not constant: it depends on the element, on the total dissolved solids and on the state of the interface, and it drifts as gold deposits on the sampler and skimmer cones during a run. An external calibration curve made in clean acid is therefore simply wrong. The combination this part specifies addresses both parts of the error. Standard addition places the calibration in the same matrix as the sample, so the suppression applies equally to the standard and to the analyte; and the internal standard, an element added at a known concentration and measured alongside, corrects the drift and the variation in uptake that occur within and between runs. What follows is the choice of internal standard for each analyte mass, the isobaric and polyatomic interferences and their correction, the sample preparation, the blank control, and the precision. Issued on 23 December 2010 and in force since 1 September 2011.
Document preview — GB/T 25934.2-2010
National Standard of the People's Republic of China
- ICS
- 77.040.30
- Classification
- H 15
Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Principle
- 4 Reagents
- 5 Apparatus
- 6 Specimens
- 7 Procedure
- 8 Expression of results
- 9 Precision
- 10 Test report
1 Scope
This part of GB/T 25934 specifies the determination of impurity elements in high purity gold by inductively coupled plasma mass spectrometry, using standard addition correction together with an internal standard.
It applies to the determination of impurity elements in gold of 99.999 per cent purity, over the elements and the concentration ranges given in Table 1.
3 Principle
The test portion is dissolved in aqua regia, the solution is made up, an internal standard is added, and the impurities are determined by ICP-MS. The calibration is by standard addition: known quantities of the analytes are added to portions of the sample solution itself, and the result is read from the intercept.
The gold is not separated out. It stays in the solution at several grams per litre throughout, and the whole design of the method is an accommodation to that fact.
4 Two corrections doing two different jobs
The standard addition corrects for the matrix effect on the analytical signal: because the additions are made into the sample solution, the calibration and the sample experience the same suppression, and the slope obtained is the one that applies.
The internal standard corrects for what changes during the run: nebuliser drift, small variations in the sample uptake, plasma fluctuation. An element not present in the sample is added at a constant level and every analyte signal is expressed as a ratio to it.
The two are not alternatives and neither covers the other. Standard addition alone is defeated by drift between the aliquots; an internal standard alone does not fix a calibration slope measured in the wrong matrix. This method uses both because at five nines the residual error from either would be a large fraction of what is being measured.
Measuring what is not there
Gold at 99.999 per cent purity contains ten parts per million of everything else combined. Certifying it means determining a dozen elements at concentrations of parts per million and below, in a solution that is almost entirely gold.
Removing the matrix would be the classical answer, and it is the wrong one here. Separating the gold - by solvent extraction, by precipitation, by ion exchange - risks carrying analytes away with it or contributing them from the reagents, and at these levels a separation introduces more uncertainty than it removes.
So the gold stays in, and the price is severe signal suppression that also drifts as the run proceeds. Standard addition and internal standardisation together are what make that workable, and it is why this method is a distinct part of the series rather than an application of a general ICP-MS procedure.
The matrix stays in
Part 1 removes the gold before measuring. This part keeps it and corrects for it.
Harder analytically, but every separation risks losing an analyte - and mass spectrometry is sensitive enough to work in the matrix directly.
Which is what makes 99.999 measurable
The detection limits sit one to two orders of magnitude below what the emission method reaches.
But the suppression is severe and moving
Percent-level gold suppresses the ion signal of everything else, and not by a constant factor: it depends on the element and the dissolved solids.
And it drifts during a run as gold deposits on the sampler and skimmer cones - so a calibration curve made in clean acid is simply wrong.
Two corrections, two errors
Standard addition puts the calibration in the same matrix as the sample, so the suppression applies equally to both.
The internal standard, added at a known concentration and measured alongside, takes out the drift and the uptake variation within and between runs.
Why five nines is a commercial number
Gold at 99.99 per cent is jewellery and bullion. Gold at 99.999 is a different product with a different market: bonding wire for semiconductors, sputtering targets, electrical contacts in instruments, and the metal used where a trace of another element changes an electrical property.
The price difference between the two is real and it rests entirely on an analytical certificate. Nobody can see the difference, no physical test distinguishes them, and the only evidence that a bar is five nines rather than four is a determination of the impurities it does not contain.
That is what a method like this one is for. It is not a process control measurement; it is the document that supports a price, which is why it specifies two independent corrections and why the series it belongs to is built around certifying purity rather than around monitoring a refinery.
Table 1 is the standard
The scope says the method applies to the elements and the ranges given in Table 1, and that table is where the real content of this part sits. It names each impurity determinable by this route and the concentration band over which the determination has been validated.
Outside those bands the method is not simply less accurate; it is unsupported. Below the lower bound the analyte is at or under the blank the reagents contribute, and above the upper one the standard addition is no longer working on a linear part of the response.
For a certificate of analysis that matters more than it would elsewhere. A laboratory reporting an element outside the validated range has reported a number this standard does not stand behind, and a buyer relying on the certificate has no way of telling from the figure alone.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 25933High-purity gold
- GB/T 25934.1Methods for the chemical analysis of high-purity gold - Part 1: Determination of impurity elements by ethyl acetate extraction separation and inductively coupled plasma atomic emission spectrometry
- GB/T 6682Water for analytical laboratory use - Specification and test methods
- GB/T 8170Rules of rounding off for numerical values & expression and judgement of limiting values
Similar standards
How to Buy GB/T 25934.2-2010
- 1Add to cart. Click the "Buy GB/T 25934.2-2010" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.