GB/T 25758.5-2010Non-destructive testing -- Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing -- Part 5: Measurement of the effective focal spot size of mini and micro focus X-ray tubes (English PDF)
无损检测 工业X射线系统焦点特性 第5部分:小焦点和微焦点X射线管的有效焦点尺寸的测量方法
This is a limited preview
Buy now to download the full PDF (5 pages)
Need quotation for your management?
Get a formal quotation for GB/T 25758.5-2010 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
December 23, 2010
Implementation date
October 1, 2011
Scope
GB/T 25758.5-2010 is the English-translated version of 无损检测 工业X射线系统焦点特性 第5部分:小焦点和微焦点X射线管的有效焦点尺寸的测量方法.
GB/T 25758.5-2010 — This section GB/T 25758 specifies the method for measuring the focal spot size of the X-ray photograph of sharp edges. This method requires focus Size between 5µm ~ 300µm, the tube voltage of the X-ray tube of up to 225kV.
X-ray image quality and resolution depends largely on the characteristics of the focus. Focus image quality based on two-dimensional target plane Distribution of radiation intensity.
For purposes of identification, the use of X-ray radiography. NOTE. If you give permission, this measurement method can be used for higher kV voltage systems, but the measurement accuracy may be reduced.
Found what you need?
Document preview — GB/T 25758.5-2010
National Standard of the People's Republic of China
- ICS
- 19.100
- Classification
- J 04
Issued by: Standardization Administration of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4.1 Principle and equipment
Foreword
GB/T 25758 "non-destructive testing of industrial X-ray system focus feature" is divided into five parts.
--- Part 1. Scanning method;
--- Part 2. Pinhole camera radiographic method;
--- Part 3. Slit camera radiographic method;
--- Part 4. Edge method;
--- Part 5. Measurement of the effective focal spot size smaller focus and micro focus X-ray tube.
This section GB/T 25758 Part 5.
This section identical with EN12543-5:1999 "Non-destructive testing - Industrial focus characteristics - Part 5 X-ray system. Small and Micro Focus Measurement of the effective focal spot size focus X-ray tube "(in English).
This section is equivalent translation EN12543-5:1999.
For ease of use, this section made the following editorial changes.
--- "This European standard" be replaced by "this section";
--- Remove the EN standard foreword;
"." --- With a decimal point instead of a comma as the decimal point, "";
--- With GB/T 1.1-2000 predetermined key words instead of the EN standard introductory phrase.
This part of the National NDT Standardization Technical Committee (SAC/TC56) and focal points.
This section is drafted. Haitai Division Inspection Technologies Ltd., Shanghai IAC NDT Technology Co., Ltd., Shanghai Research Institute of Materials, Shanghai - Friends Industrial Co., Ltd., Shanghai Wei Cheng Banda Detection Technology Co., Ltd., GE Sensing & Inspection Technologies (Shanghai) Co., Ltd., Dan East Austrian-ray machines Limited, Shandong Institute of Light Industry.
Introduction
In order to meet the needs of different focal spot size measured in GB/T 25758.1 ~ 25758.5, the five different methods are described.
Scanning method (GB/T 25758.1) applies constant focal spot size and intensity distribution of the occasion, for example, for calibration and image processing process.
Radiographic methods (GB/T 25758.2 and GB/T 25758.3) is a conventional technique, in order to verify that the primary purpose for the highest to 200kV occasions.
When the pinhole camera can not be used and slit edge method (GB/T 25758.4) may be effective, this method is suitable for simple Occasions.
In order to take into account micro-focus system, GB/T 25758.5 \u200b\u200bproposes a special approach.
Non-destructive testing of industrial X-ray system focus feature Part 5. Focus small and micro-focus X-ray tube Measurement of the effective focal spot size
1 Scope
This section GB/T 25758 specifies the method for measuring the focal spot size of the X-ray photograph of sharp edges. This method requires focus Size between 5µm ~ 300µm, the tube voltage of the X-ray tube of up to 225kV.
X-ray image quality and resolution depends largely on the characteristics of the focus. Focus image quality based on two-dimensional target plane Distribution of radiation intensity.
For purposes of identification, the use of X-ray radiography.
NOTE. If you give permission, this measurement method can be used for higher kV voltage systems, but the measurement accuracy may be reduced.
2 Normative references
The following documents contain provisions which, through reference GB/T 25758 in this section constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
GB/T 19348.1 destructive testing - Industrial radiographic film - Part 1. Classification of film systems for industrial radiography 1) (GB/T 19348.1-2003, ISO 11699-1:1998, IDT)
1) This standard will be revised GB/T release (identical with ISO 11699-1 19348.1-2003 on the basis of 2008, and EN584-1:1994 equivalent).
GB/T 25758.1 destructive testing of industrial X-ray system focus characteristics - Part 1. Scanning method (GB/T 25758.1-2010, EN12543-1:1999, IDT)
3 Terms and Definitions
The following terms and definitions apply to this part of the GB/T 25758 of.
Focus focalspot
X-ray emission from the region to see the measuring device X-ray tube anode.
[GB/T 25758.1]
Test Method 4
4.1 Principle and equipment
This method is an indirect measurement method by measuring geometric clarity to get focus size. For this reason, the use of a relatively high discharge geometry Large magnification will clear the upper edge of the image to film or ray fluoroscopy devices.
If using film, the measurement requires the following equipment.
--- Test object as described later;
--- No minimum size of 10cm × 10cm intensifying screen the film;
--- Low-absorption material film cartridge (e.g., polyethylene);
--- Film cartridge;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 19348.1Non-destructive testing -- Industrial radiographic film -- Part 1: Classification of film systems for industrial radiography
- GB/T 19348.1-2003Non-destructive testing -- Industrial radiographic film -- Part 1: Classification of film systems for industrial radiography
- GB/T 25758.1Non-destructive testing -- Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing -- Part 1: Scanning method
- GB/T 25758.1-2010Non-destructive testing -- Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing -- Part 1: Scanning method
GB/T 25758 · ISO 11699
How to Download GB/T 25758.5-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 19348.1-2014 — Non-destructive testing -- Industrial radiographic film -- Part 1: Classification of film systems for industrial radiography
GB/T 25758.1-2010 — Non-destructive testing -- Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing -- Part 1: Scanning method
GB/T 25758.2-2010 — Non-destructive testing -- Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing -- Part 2: Pinhole camera radiographic method
Secure payment via Stripe
Payments accepted
GB/T 25758.5-2010
$75.00