GB/T 25753.1-2010Vacuum technology -- Roots vacuum pump -- Measurement of performance characteristics -- Part 1: Measurement of maximum tolerable differential pressure (English PDF)
真空技术 罗茨真空泵性能测量方法 第1部分:最大允许压差的测量
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for GB/T 25753.1-2010 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
December 23, 2010
Implementation date
October 1, 2011
Scope
GB/T 25753.1-2010 is the English-translated version of 真空技术 罗茨真空泵性能测量方法 第1部分:最大允许压差的测量.
GB/T 25753.1-2010 — GB/T 25753 provisions of this part of the Roots vacuum pump the maximum allowable differential pressure measurement method. This section applies to a pumping speed 30L/s ~ 20000L/s Roots vacuum pump (hereinafter referred to as the pump).
Found what you need?
Document preview — GB/T 25753.1-2010
National Standard of the People's Republic of China
- ICS
- 23.160
- Classification
- J 78
Issued by: Standardization Administration of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Terms and definitions
- 3 Devices
- 3.1 Test cap
Foreword
GB/T 25753 "Roots vacuum pumps - Measurement of performance art" is divided into three parts.
--- Part 1 maximum allowable differential pressure measurement;
--- Part 2 compression ratio of zero flow measurement;
--- PART 3 relief valve differential pressure measurement.
This is Part 1 GB/T 25753 of.
This part is proposed by China Machinery Industry Federation.
This part of the National Vacuum Technology Standardization Technical Committee.
This section is responsible for drafting. Zhejiang Vacuum Equipment Group Co., Ltd.
Participated in the drafting of this section. Chengdu South-ray machines Limited, Shenyang Institute of Scientific Instrument Development Center, Shandong Zibo Vacuum Equipment Co., Ltd., Anhui Hefei Science and Technology Co., Ltd., Shenyang Institute of Vacuum Technology.
Introduction
With the development of basic industries and design innovation, design and performance Roots pump structure have made considerable Progress early Roots vacuum pumps must rely on pre-pump operation, and now the development of a direct atmospheric discharge run-cooled Roots Roots vacuum pumps and wet, the other a single series Roots vacuum pump has become the single-stage, two-stage, multi-stage, rotor profile also Futaba become the double leaf, clover, leafy.
Existing Roots vacuum pump performance measure encompasses only a single-stage double-lobe Roots pump, other types of basic not involved, and not made on how to measure the differential pressure relief valve specifications, to effectively improve the Roots vacuum pump performance measurement standards compatibility and suitability for the practical Test measurements provide the necessary operating instructions, drawing in a wide range of domestic and foreign-related indicators, benchmarks, based on the actual situation, the development of the "vacuum Roots vacuum pump performance measurement technology "standards, and is divided into three parts. Extreme pressure and pumping rate of the Roots vacuum pump unit Energy measurements, not according to the standard content. In the future will make the necessary modifications and expansion basis of technological development.
Roots vacuum pumps - Measurement of performance art Part 1. The maximum allowable differential pressure measurement
1 Scope
GB/T 25753 provisions of this part of the Roots vacuum pump the maximum allowable differential pressure measurement method.
This section applies to a pumping speed 30L/s ~ 20000L/s Roots vacuum pump (hereinafter referred to as the pump).
2 Terms and definitions
The following terms and definitions apply GB/T 25753 in this section.
The maximum allowable pressure maximumtolerabledifferentialpressure the maximum allowable pressure refers to the continuous operation of the pump 1h, the maximum allowed by abnormal outlet pressure and the inlet pressure difference does not occur. for Roots vacuum pump inlet pressure measurement should be equal to or slightly less than 1 × 103Pa.
Note. For other types of Roots vacuum pumps without inlet pressure value requirements, but should be appropriate for the structure of the pump, or follow the manufacturer's recommendations.
Test cover testdome
Special vacuum vessel having a predetermined precise shape and dimensions, through which the gas to be measured into the pump, on which pressure measurement Means.
3 Devices
3.1 Test cap
As shown in Figure 1, the shape of a cylinder. The axial dimension of the cover is 1.5D, D is the inner diameter of the housing. Test gas inlet is located in the axis of the cover on the connection flange and the distance is D, arranged in the intake port should be such that the gas from the direction away from the pump into the test port cover. Measuring the inlet pressure Gauge distance 0.5D connecting flange at its axis is perpendicular to the axis of the cover. Testing should cover the axis perpendicular to the pump inlet flange plane.
In addition to the intake line, the connecting line between the flange and the test covers the inner wall of the test should not wear a cap.
VD test cover volume should be at least one compression cycle pump swept five times the volume of the VP. In the pump inlet should be connected to a reducer fittings, its length should not exceed 0.5D (see Figure 1). Different specifications of the pump for test cover given in Table 1.
Table 1 Test parameters cover
VP/L VD/LD/mm
0 0.26 1.3 100
0.26 1.0 5.4 160
1.1 ~ 4.2 21250
4.2 ~ 1784400
17 to 65 325 630
65 - 26013001000
260 to 106,053,001,600 1060 - 4060203002500
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
Referenced standards
How to Download GB/T 25753.1-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 25753.2-2010 — Vacuum technology -- Roots vacuum pump -- Measurement of performance characteristics -- Part 2: Measurement of compression ratio of the zero throughput
GB/T 25753.3-2011 — Vacuum technology -- Roots vacuum pump -- Measurement of performance characteristics -- Part 3: Measurement of overflow valve differential pressure
GB/T 25753.4-2015 — Vacuum technology - Roots vacuum pump - Measurement of performance characteristics - Part 4: Measurement of noise
Secure payment via Stripe
Payments accepted
GB/T 25753.1-2010
$105.00