GB/T 25444.6-2023Mobile and fixed offshore units - Electrical installations - Part 6: Installation (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (29 pages)

Need quotation for your management?

Get a formal quotation for GB/T 25444.6-2023 in 30 minutes.

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

December 28, 2023

Implementation date

April 1, 2024

Scope

GB/T 25444.6-2023 (Mobile and fixed offshore units - Electrical installations - Part 6: Installation) is available as an English-translated PDF.

GB/T 25444.6-2023 — This document specifies the installation requirements for electrical installations on mobile and fixed offshore installations, including those used in offshore oil industry drilling, production Pipelines, pumping stations or pipeline cleaning stations, air compressor stations and single buoy mooring facilities for production, accommodation, processing, oil storage and unloading: This document specifies the following requirements: ---Protection during equipment storage and installation; ---Generator and motor installation; ---Transformer installation; ---Installation of complete sets of switchgear and control equipment; ---Semiconductor inverter and UPS installation; ---Battery and battery installation; ---Lighting installation; ---Installation of electric heaters and electric cookers; ---Installation of heat tracing and surface heating devices; ---Installation of low-voltage and high-voltage cables and wires; ---Grounding and bonding requirements; ---Lightning protection; ---Completion test; ---document: This document applies to all permanent, temporary, mobile or handheld AC and DC installations, regardless of voltage level: ginseng the equipment standards may provide voltage level restrictions: This document does not apply to the following devices: ---Medical fixed electrical devices; ---Electrical installation of liquid cargo ship; --- Ignition source control equipment other than ignition sources generated by electrical equipment: Note 1: IEC 60364-7-710 has specific requirements for medical rooms: The requirements for oil tankers are found in IEC 60092-502: Note 2: For guidance on the protection of non-electrical equipment, see ISO 80079-36, ISO 80079-37 and 6:7 of the IMO2009 MODU rules:

Found what you need?

Document preview — GB/T 25444.6-2023

National Standard of the People's Republic of China

ICS
47.020.60
Classification
U 60
Replacing
GB/T 25444.6-2010

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 General Principles
  • 4.1 Label
  • 4.2 Protection of equipment during storage
  • 4.3 Protection during equipment installation
  • 5 Generators and Motors---Installation
  • 6 Transformer---Installation and Arrangement
  • 7 Switchgear and controlgear combinations
  • 7.1 Position
  • 7.2 Insulating grid or insulating pad
  • 7.3 Access to the front of the switchgear and controlgear combination
  • 7.4 Space and access at the rear
  • 8 Semiconductor converter
  • 9 Batteries and battery packs
  • 9.1 General requirements
  • 9.2 Position
  • 9.3 Electrical installation of battery room
  • 9.4 Corrosion prevention measures
  • 9.5 Fixing and supporting
  • 9.6 Protection against electric shock
  • 9.7 Signage or logo
  • 10 Uninterruptible power supply system
  • 11 Lighting 10
  • 11.1 Protection level and safety requirements 10
  • 11.2 Emergency and escape lighting 10
  • 11.3 Navigation aid and obstacle light system
  • 12 Electric heaters and electric cookers 10
  • 12.1 Protection of flammable materials 10
  • 12.2 Location of controls and switching gear 10
  • 13 Heat tracing and surface heating 10
  • 13.1 General requirements
  • 13.2 Heating cable
  • 13.3 Flag
  • 13.4 Protection
  • 13.5 Hazardous area installation requirements
  • 13.6 Mechanical protection 11
  • 13.7 Junction box
  • 14 Cables and Wires 11
  • 14.1 General requirements
  • 14.2 Installation
  • 14.3 Cable laying
  • 14.4 Bending radius
  • 14.5 Cable clamps and binding 13
  • 14.6 Connectors and branch circuits
  • 14.7 Cable stuffing box---plugs and drain plugs 14
  • 14.8 Cable connection
  • 14.9 Cable transit systems
  • 14.10 Cable ladders and brackets 16
  • 15 Equipment Grounding and Bonding
  • 15.1 General requirements
  • 15.2 Grounding of exposed conductive parts 17
  • 15.3 Equipotential bonding
  • 15.4 Connecting wires
  • 15.5 Connecting to unit structures
  • 15.6 Galvanic corrosion protection
  • 15.7 Cable metal covering
  • 15.8 Cable supports and brackets
  • 16 Lightning protection device
  • 16.1 Direct lightning protection system
  • 16.2 Lightning rod
  • 16.3 Indirect lightning protection system
  • 17 Communication 20
  • 18 Completion test
  • 18.1 Inspection and testing
  • 18.2 Insulation test instruments
  • 18.3 Insulation resistance
  • 18.4 Generator set
  • 18.5 Switchgear
  • 18.6 Lighting, electric heaters and kitchen equipment 22
  • 18.7 Communication Systems
  • 18.8 Emergency and safety systems 23
  • 18.9 Ground
  • 18.10 Voltage drop
  • 18.11 Provisions of international conventions and rules 23
  • 19 Document
  • 19.1 General requirements
  • 19.2 Equipment
  • 19.3 Test
  • 19.4 Maintenance
  • Appendix A (Informative) Performance Test
  • Appendix B (informative) Cable terminal example
  • Reference
  • Figure 1 Recommended layout for single-core cable laying---tiled structure
  • Figure 2 Recommended layout for single-core cable laying --- three-leaf structure
  • Figure B:1 Equipment with stuffing box
  • Figure B:2 Equipment that needs to be grounded---Exd preparation armored clamping stuffing box
  • Figure B:3 Equipment that does not require grounding --- Exd braided armored clamping stuffing box --- Instrument cable terminal
  • Figure B:4 Equipment that requires grounding --- Exd braided armored clamping stuffing box --- Power cable terminal block
  • Figure B:5 Heat shrink isolation between outer braided armor and electrostatic shield 28
  • Table 1 Location and charging power of battery pack
  • Table 2 Bending radius of cables with rated voltage 1:8/3kV
  • Table 3 Bending radius of cables with rated voltages from 3:6/6:0(7:2)kV to 18/30kV (inclusive)13
  • Table 4 Housing---stuffing box type
  • Table 5 Dimensions for grounding conductors and equipment grounding connections 17
  • Table 6 Test voltage

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents" Drafting:

This document is Part 6 of GB/T 25444 "Electrical Installations for Mobile and Fixed Offshore Installations": GB/T 25444 has been issued the following parts have been published:

---Part 1: General requirements and conditions;

---Part 2: System Design;

---Part 3: Equipment;

---Part 5: Mobile facilities;

---Part 6: Installation;

---Part 7: Hazardous areas:

This document replaces GB/T 25444.6-2010 "Electrical installations for mobile and fixed offshore installations - Part 6: Installation" and is consistent with Compared with GB/T 25444.6-2010, in addition to structural adjustments and editorial changes, the main technical changes are as follows:

a) The applicable limits of the scope have been changed (see Chapter 1, Chapter 1 of the:2010 edition);

b) Changes in terms and definitions (see Chapter 3, Chapter 3 of the:2010 edition);

c) The general requirements have been changed (see Chapter 4, 4:1 of the:2010 edition);

d) Added layout requirements and types of transformers (see 6.1);

e) Added installation and capacity requirements for receiving tanks (see 6.6);

f) Changed the requirements for referenced documents (see 7.1:1, 8:2:1 of the:2010 version);

g) Deleted winding insulation (see 7.3 of the:2010 edition);

h) Changed the width of barrier-free passages and added requirements for passages between switchboard lines and circuit breaker passages (see 7.3,:2010 edition of 8:4);

i) Delete the special requirements for the enclosure of the switchboard in the accommodation area (see 8.6 of the:2010 edition);

j) Changed the installation requirements for batteries and battery packs (see Chapter 9, Chapter 10 of the:2010 edition);

k) Added UPS installation requirements (see Chapter 10);

l) Delete the requirements for discharge lamps with voltages higher than 250V (see 11.3 of the:2010 edition);

m) The installation requirements for cabin electric heaters are deleted (see 12.3 of the:2010 edition);

n) The requirements for heating cables have been changed (see 13.2, 13:2 of the:2010 edition);

o) Changed the marking requirements for heating cables and heating equipment (see 13.3,:2010 version of 13:3);

p) Changes to general requirements for cables and wires, installation, cable laying, cable clamping and binding, cable stuffing boxes, cable wiring, cable ladders Racks and brackets are added, and explosion-proof cable installation requirements, special requirements for cable installation for intrinsically safe systems, bending radius, joints and points are added:

Requirements for branch circuits and cable transit systems, and requirements for equipment interconnection cables and wiring have been deleted (see Chapter 14, Chapter 5 of the:2010 edition);

q) The content of exempted parts that should be grounded has been changed (see 15.2:1, 4:2:1 of the:2010 edition);

r) Changed the dimension table of grounding conductors and equipment grounding (see 15.2:2, 4:2:2 of the:2010 edition);

s) Added grounding requirements for metal enclosures, pipes and conduits or trunking and grounding requirements for hulls and equipment not seam welded to the structure (see 15.3:4, 15:3:5);

t) The cross-sectional area of the equipotential bonding conductor has been changed (see 15.4:3, 4:4:3 of the:2010 edition);

u) The requirements for galvanic corrosion protection have been changed (see 15.6, 4:6 of the:2010 edition);

v) Changed the requirements for cable metal covering (see 15.7, 4:7 of the:2010 edition);

w) Pipes and containers for heating, ventilation and air conditioning equipment are deleted (see 4.9 of the:2010 edition);

x) The direct lightning protection system, lightning rod, and indirect lightning protection system have been changed (see Chapter 16, 16:2, 16:3 and 16:5 of the:2010 edition);

y) Changed the test requirements for complete cables operating at 1kV and above (see 18.1:4, 17:2:4 of the:2010 edition);

z) Added safety extra-low voltage and protective extra-low voltage tests (see 18.2):

This document is equivalent to IEC 61892-6:2019 "Electrical installations for mobile and fixed offshore installations - Part 6: Installation":

Please note that some content in this document may be subject to patents: The publisher of this document assumes no responsibility for identifying patents:

Introduction

GB/T 25444 "Electrical Installations for Mobile and Fixed Offshore Facilities" aims to cover general requirements, system design, equipment, cables, mobile Facilities, installation and hazardous areas, etc:, proposed designs for electrical equipment in mobile and fixed offshore facilities used for petroleum exploration or extraction:

Design, installation, maintenance and use requirements, applicable to pipelines, pumping stations or pipelines for drilling, production, accommodation, processing, oil storage and unloading in the offshore oil industry in-tube cleaning station, air compressor station and single buoy mooring facility:

GB/T 25444 is planned to consist of seven parts:

---Part 1: General requirements and conditions: The purpose is to provide for mobile and fixed offshore installations used for petroleum exploration or extraction General requirements for electrical installations:

---Part 2: System Design: The purpose is to specify systems for mobile and fixed offshore installations used in petroleum exploration or extraction Design requirements:

---Part 3: Equipment: The purpose is to specify the design of equipment for mobile and fixed offshore installations used in petroleum exploration or extraction:

and testing requirements:

---Part 4: Cables: The purpose is to provide for the electrical installation of mobile and fixed offshore installations used in petroleum exploration or extraction:

Cable selection requirements:

---Part 5: Mobile facilities: The purpose is to provide for the electrical Additional features of the device:

---Part 6: Installation: The purpose is to provide for the electrical installation of mobile and fixed offshore installations used in petroleum exploration or extraction:

installation requirements:

---Part 7: Hazardous areas: The purpose is to regulate the hazards of mobile and fixed offshore installations used for petroleum exploration or extraction:

Area classification and selection requirements for electrical equipment in hazardous areas:

GB/T 25444 aims to form a series of standards applicable to electrical equipment in the offshore petroleum industry, but is not limited to petroleum equipment:

use:

Electrical installations for mobile and fixed offshore installations Part 6: Installation

1 Scope

This document specifies the installation requirements for electrical installations on mobile and fixed offshore installations, including those used in offshore oil industry drilling, production Pipelines, pumping stations or pipeline cleaning stations, air compressor stations and single buoy mooring facilities for production, accommodation, processing, oil storage and unloading:

This document specifies the following requirements:

---Protection during equipment storage and installation;

---Generator and motor installation;

---Transformer installation;

---Installation of complete sets of switchgear and control equipment;

---Semiconductor inverter and UPS installation;

---Battery and battery installation;

---Lighting installation;

---Installation of electric heaters and electric cookers;

---Installation of heat tracing and surface heating devices;

---Installation of low-voltage and high-voltage cables and wires;

---Grounding and bonding requirements;

---Lightning protection;

---Completion test;

---document:

This document applies to all permanent, temporary, mobile or handheld AC and DC installations, regardless of voltage level: ginseng the equipment standards may provide voltage level restrictions:

This document does not apply to the following devices:

---Medical fixed electrical devices;

---Electrical installation of liquid cargo ship;

--- Ignition source control equipment other than ignition sources generated by electrical equipment:

Note 1: IEC 60364-7-710 has specific requirements for medical rooms: The requirements for oil tankers are found in IEC 60092-502:

Note 2: For guidance on the protection of non-electrical equipment, see ISO 80079-36, ISO 80079-37 and 6:7 of the IMO2009 MODU rules:

2 Normative reference documents

The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, the dated quotations for undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document:

GB/T 21714.3-2015 Lightning protection Part 3: Physical damage to buildings and danger to life (IEC 62305-3:

2010,IDT)

IEC 60092-350:2020 Ship electrical installations Part 350: General structural and test requirements for ship power cables (Electri-

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 29 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 25444.6-2023

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
29 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 25444.6-2023

$575.00