GB/T 25439-2010Standard method for using cellulose triacetate dosimetry system to measure absorbed dose (English PDF)
使用三醋酸纤维素剂量测量系统测量吸收剂量的标准方法
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for GB/T 25439-2010 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
November 10, 2010
Implementation date
May 1, 2011
Scope
GB/T 25439-2010 is the English-translated version of 使用三醋酸纤维素剂量测量系统测量吸收剂量的标准方法.
GB/T 25439-2010 — 1.1 standard specifies the use of cellulose triacetate (CTA) dosimetry systems for measuring electron and photon radiation, water absorbent Scale Shown is absorbed radiation dose and dose distribution in the material handling and testing procedures.
CTA dosimeter is a suitable dose distribution measurement Work dosimeter. 1.2 CTA standard dosimetry system suitable conditions. a) absorbed dose range. 10kGy ~ 300kGy (electrons and photons). b) absorbed dose rate range.
3Gy · s-1 ~ 4 × 1010Gy · s-1. c) electron irradiation energy range. 0.2MeV ~ 50MeV. d) radiation photon energy range. 0.1MeV ~ 50MeV. e) dosimeter irradiation temperature range. -10 °C ~ 70 °C. 1.3 This standard does not involve security issues associated with its use.
Users of this standard is responsible for establishing the applicable safety and health standards and make Before use to determine its limits applicable.
Found what you need?
Document preview — GB/T 25439-2010
National Standard of the People's Republic of China
- ICS
- 17.240
- Classification
- A 58
Issued by: Standardization Administration of China
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- Meaning and use 3
- 5 Dosimetry system
- 6 Dosimeter Preparation
- Calibration of dosimetry systems 7
- 8 Measurement
- 9 General
- 10 Environmental and other factors
- 11 Record requirements
- 12 7 Measurement Uncertainty
- Keywords 7
- Appendix A (Informative Appendix) CTA film dosimeters infos
- Reference
Foreword
This standard is identical with ISO/ASTM51650:2005 "cellulose triacetate dosimetry system application standards" (in English).
This standard is equivalent translation ISO/ASTM51650:2005.
For ease of use, this standard made the following editorial changes.
--- The standard name is now changed to "the use of cellulose triacetate dosimetry systems for measurement of absorbed dose standard method";
--- In Chapter 2, "Normative references", the referenced ISO and ASTM standards, who have converted to our standards, references to Our standards;
--- According to the requirements of the standard preparation of some of the formatting to be modified;
--- International standards misprints modification;
--- International standard appendix A has been modified, added other CTA film dosimeters information, delete the international standards Appendix A for information about photometer.
Appendix A of this standard is the data appendix.
The standard proposed by China National Nuclear Corporation.
This standard by the National Standardization Technical Committee on Nuclear Energy (SAC/TC58) centralized.
This standard was drafted. China Institute of Atomic Energy.
1 Scope
1.1 standard specifies the use of cellulose triacetate (CTA) dosimetry systems for measuring electron and photon radiation, water absorbent Scale Shown is absorbed radiation dose and dose distribution in the material handling and testing procedures. CTA dosimeter is a suitable dose distribution measurement Work dosimeter.
1.2 CTA standard dosimetry system suitable conditions.
a) absorbed dose range. 10kGy ~ 300kGy (electrons and photons).
b) absorbed dose rate range. 3Gy · s-1 ~ 4 × 1010Gy · s-1.
c) electron irradiation energy range. 0.2MeV ~ 50MeV.
d) radiation photon energy range. 0.1MeV ~ 50MeV.
e) dosimeter irradiation temperature range. -10 °C ~ 70 °C.
1.3 This standard does not involve security issues associated with its use. Users of this standard is responsible for establishing the applicable safety and health standards and make Before use to determine its limits applicable.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 16509 doses of radiation processing of Measurement Uncertainty guidelines (GB/T 16509-2008, ISO/ASTM51707.
2005, IDT)
GB/T 16510 radiation processing dosimetry calibration laboratory competency requirements (GB/T 16510-2008, ISO/ASTM51400.
2002, IDT)
Selection and calibration of the guide GB/T 16640 dosimetry systems for radiation processing is (GB/T 16640-2008, ISO/ASTM51261:2002, IDT) the term ASTME170 radiometry and dosimetry Determination ASTME177 material properties in terms of precision and accuracy of application profiles ASTME178 deviation observed value processing specification ASTME925 narrow pass band regularly calibrated spectrophotometer specification ASTME958 UV - Vis spectral bandwidth for measurement of actual Report No. ICRU14 radiation dosimetry. the maximum photon energy between 0.6MeV ~ 50MeV X-rays and gamma-rays X-ray voltage between 5kV ~ 150kV produced. Report No. ICRU17 radiation dosimetry Report No. ICRU34 pulsed radiation dosimetry Report No. ICRU35 radiation dosimetry. energy between 1MeV ~ 50MeV electron beam Report No. ICRU37 electrons and positrons stopping power Report No. ICRU60 basic Ionizing Radiation Quantities and Units
3 Terms and Definitions
ASTME170 and No. ICRU60 report and established the following terms and definitions apply to this standard.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 16509Standard guide for estimating uncertainties in dosimetry for radiation processing
- GB/T 16509-2008Standard guide for estimating uncertainties in dosimetry for radiation processing
- GB/T 16510The requirements for the competence of a radiation processing dosimetry calibration laboratory
- GB/T 16510-2008The requirements for the competence of a radiation processing dosimetry calibration laboratory
- GB/T 16640Standard guide for selection and calibration of dosimetry systems for radiation processing
- GB/T 16640-2008Standard guide for selection and calibration of dosimetry systems for radiation processing
ISO/ASTM51707 · ISO/ASTM51400 · ISO/ASTM51261
How to Download GB/T 25439-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16509-2008 — Standard guide for estimating uncertainties in dosimetry for radiation processing
GB/T 16510-2008 — The requirements for the competence of a radiation processing dosimetry calibration laboratory
GB/T 16640-2008 — Standard guide for selection and calibration of dosimetry systems for radiation processing
Secure payment via Stripe