GB/T 25105.1-2025Industrial communication networks - Fieldbus specifications - Type 10: PROFINET IO specifications - Part 1: Application layer service definition (English PDF)
This is a limited preview
Buy now to download the full PDF (719 pages)
Need quotation for your management?
Get a formal quotation for GB/T 25105.1-2025 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
April 25, 2025
Implementation date
November 1, 2025
Scope
GB/T 25105.1-2025 (Industrial communication networks - Fieldbus specifications - Type 10: PROFINET IO specifications - Part 1: Application layer service definition) is available as an English-translated PDF.
GB/T 25105.1-2025 — The Fieldbus Application Layer (FAL) provides user programs with a means to access the Fieldbus communication environment. In this respect, the FAL can be viewed as for "windows between corresponding applications".
This document provides basic time-critical and non-time-critical messaging between applications in an automation environment.
The term "time-critical" is used to indicate the existence of a time window within which the A time window is a time window in which one or more specified actions are required to be completed with a certain level of certainty.
If these actions are not performed properly, there is a risk that the application requesting these actions will fail, and even cause danger to instruments, equipment and possible personal injury.
This document defines the externally visible functions provided by the PROFINET IO fieldbus application layer in an abstract way from the following aspects.
Serve. a) define an abstract model of application resources (objects) that users can utilize by using FAL services; b) primitive actions and events of services; c) The parameters associated with each primitive action and event and the form it takes.
The interrelationships between these actions and events and their effective sequence.
The purpose of this document is to define a number of services provided to. a) FAL user at the interface between the user and application layers of the fieldbus reference model; b) System management at the interface between the application layer and system management of the fieldbus reference model.
This part is based on the OSI basic reference model (see ISO/IEC 7498-1) and the OSI application layer structure (see ISO/IEC 9545). The structure and services of the PROFINET IO fieldbus application layer.
FAL services and protocols are provided by the FAL Application Entity (AE) contained in the application process. FALAE consists of a set of object-oriented the ASE is composed of an application service element (ASE) and a layer management entity (LME) that manages the AE.
The ASE provides access to a set of related application process objects. (APO) class to operate the communication service. One element in FALASE is the management ASE, which provides a common service set for Management of FAL class instances.
Although these services specify how to issue and transmit requests and responses from the application's perspective, they do not include how the request and response applications handle that is, it does not specify the behavior of the application, but only specifies what kind of requests and responses can be sent/received.
In this way, FAL users are given greater flexibility in standardizing the behavior of such objects. In addition to these services, this document defines Some support services are accessed by the FAL to control certain aspects of its operation.
Found what you need?
Document preview — GB/T 25105.1-2025
National Standard of the People's Republic of China
- ICS
- 25.040
- Classification
- N 10
- Replacing
- GB/T 25105.1-2014
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Preface
- Introduction
- 1 Scope
- 1.1 General
- 1.2 Specification
- 1.3 Consistency
- 2 Normative references
- 3 Terms, Definitions, Abbreviations, Symbols and Conventions
- 3.1 Referenced terms and definitions
- 3.2 Additional terms and definitions for Type 10
- 3.3 Additional terms and definitions for type 10 of media redundancy
- 3.4 Abbreviations and symbols
- 3.5 Agreement
- 4 Concept
- 5 Data Type ASE
- 5.1 Introduction
- 5.2 Formal definition of data type objects
- 5.3 Data types defined by FAL
- 5.4 Data Type ASE Service Specification
- 6 Communication Model for Generic Services
- 6.1 Concept
- 6.2 ASE Data Types
- 6.3 ASE
- 6.4 Additional Information
- 7 Communication Model for Distributed I/O
- 7.1 Concepts
- 7.2 ASE Data Types
- 7.3 ASE
- 7.4 Application Characteristics
- 7.5 Overview of FAL Services
- Appendix A (Informative) Equipment Example
- Appendix B (Informative) Ethernet Interface Components
- Appendix C (Informative) MAC Address Allocation Mechanism
- Appendix D (Informative) Fast Startup Time Measurement
- Appendix E (Informative) Dynamic Frame Packing
- Appendix F (Informative) Prerequisites for diagnosis
- References
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting.
This document is part 1 of GB/T 25105 "Industrial Communication Network Fieldbus Specification Type 10.PROFINET IO Specification" GB/T 25105 has published the following parts.
--- Part 1: Application layer service definition;
--- Part 2: Application layer protocol specification;
--- Part 3: PROFINET IO communication profile.
This document replaces GB/T 25105.1-2014 "Industrial Communication Network Fieldbus Specification Type 10.PROFINET IO Specification" Part 1: Application layer service definition. Compared with GB/T 25105.1-2014, in addition to structural adjustments and editorial changes, the main technical the changes are as follows.
--- Increased system redundancy (see 7.1.6, 7.3.1);
--- Added time-sensitive networks (see 6.3.3, 6.3.6, 6.3.7, 6.3.11, 6.3.16~6.3.18, 7.3.3, 7.3.9), including remote servers Service interface, communication interface management, time perception system, network configuration protocol, etc.;
---Added dynamic frame packing (see 7.3.3, Appendix E).
The following minimal editorial changes were made to this document.
---Change the standard name to "Industrial Communication Network Fieldbus Specification Type 10.PROFINETIO Specification Part 1 Part 1: Application layer service definition.
This document is equivalent to IEC 61158-5-10:2023 "Industrial Communication Network Fieldbus Specification Part 5-10.Application Layer Services Definition Type Part 10.
Introduction
The GB/T 25105 series of standards consists of the following parts.
--- Part 1: Application layer service definition. The purpose is to provide a time-sensitive and non-critical communication platform for applications in an automation environment.
Time-critical message communication provides common elements and PROFINET IO fieldbus-specific information, defined in an abstract way the PROFINETIO fieldbus application layer provides externally visible services. It includes. abstract model of application resources (objects);
primitive actions and events of the service; parameters associated with each primitive action and event.
--- Part 2: Application layer protocol specification. The purpose is to define the PROFINETIO fieldbus application layer in an abstract way the externally visible behavior of the application layer protocol data unit transmitted between communication application entities.
The input syntax, the application context state machine of the application service behavior, and the application relationship state machine of the communication behavior.
--- Part 3: PROFINET IO communication profile. The purpose is to define a family of communication profiles for real-time Ethernet (RTE) (CPF3). CPF3 specifies a set of real-time Ethernet communication profiles and a set of IEC 61158 series (type
10) ISO/IEC/IEEE8802-3 and other standard related network components. For RTE communication rules, relevant RTE performance indicators and the relationship between performance indicators.
Industrial Communication Network Fieldbus Specification Type 10.
PROFINET IO Specification Part 1: Application Layer Service Definition
1 Scope
1.1 General
The Fieldbus Application Layer (FAL) provides user programs with a means to access the Fieldbus communication environment. In this respect, the FAL can be viewed as for "windows between corresponding applications".
This document provides basic time-critical and non-time-critical messaging between applications in an automation environment.
The term "time-critical" is used to indicate the existence of a time window within which the A time window is a time window in which one or more specified actions are required to be completed with a certain level of certainty.
If these actions are not performed properly, there is a risk that the application requesting these actions will fail, and even cause danger to instruments, equipment and possible personal injury.
This document defines the externally visible functions provided by the PROFINET IO fieldbus application layer in an abstract way from the following aspects.
Serve.
a) define an abstract model of application resources (objects) that users can utilize by using FAL services;
b) primitive actions and events of services;
c) The parameters associated with each primitive action and event and the form it takes.
The interrelationships between these actions and events and their effective sequence.
The purpose of this document is to define a number of services provided to.
a) FAL user at the interface between the user and application layers of the fieldbus reference model;
b) System management at the interface between the application layer and system management of the fieldbus reference model.
This part is based on the OSI basic reference model (see ISO/IEC 7498-1) and the OSI application layer structure (see ISO/IEC 9545).
The structure and services of the PROFINET IO fieldbus application layer.
FAL services and protocols are provided by the FAL Application Entity (AE) contained in the application process. FALAE consists of a set of object-oriented the ASE is composed of an application service element (ASE) and a layer management entity (LME) that manages the AE. The ASE provides access to a set of related application process objects.
(APO) class to operate the communication service. One element in FALASE is the management ASE, which provides a common service set for Management of FAL class instances.
Although these services specify how to issue and transmit requests and responses from the application's perspective, they do not include how the request and response applications handle that is, it does not specify the behavior of the application, but only specifies what kind of requests and responses can be sent/received.
In this way, FAL users are given greater flexibility in standardizing the behavior of such objects. In addition to these services, this document defines Some support services are accessed by the FAL to control certain aspects of its operation.
1.2 Specifications
The primary objective of this document is to define application layer service characteristics that are conceptually suitable for time-critical communications, thereby providing guidance for the development of it supplements the OSI basic reference model when developing application layer protocols for communications with strict time requirements.
The second goal is to provide an upgrade path for existing industrial communication protocols. It is this goal that led to the standardization of services in IEC 61158-5.
The various types of services and the various types of corresponding standardized protocols in IEC 61158-6.
This document can be used as the basis for a formal application programming interface, but it is not a formal programming interface. Any formal interface must address
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 719 pages — is available in the English PDF.
Referenced standards
How to Download GB/T 25105.1-2025
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 25105.3-2025 — Industrial communication networks - Fieldbus specifications - Type 10: PROFINET IO specifications - Part 3: PROFINET IO commuication profile
GB/T 18088-2026 — Sampling for entry and exit animal quarantine
GB/T 47983-2026 — Technical requirements for on-board energy consumption monitoring of passenger cars
Secure payment via Stripe
Payments accepted
GB/T 25105.1-2025
$11,765.00