Scope
GB/T 24585-2009 is the English-translated version of 镍铁 磷、锰、铬、铜、钴和硅含量的测定 电感耦合等离子体原子发射光谱法.
GB/T 24585-2009 is the Chinese standard "Ferronickel - Determination of Phosphorus, Manganese, Chromium, Copper, Cobalt and Silicon Contents - Inductively Coupled Plasma Atomic Emission Spectrometric Method".
Its scope clause reads: This Standard specifies the use of inductively coupled plasma atomic emission spectrometric method (ICP-AES) to determine the contents of phosphorus, manganese, chromium, cobalt, copper and silicon.
This Standard is applicable to the determination of phosphorus, manganese, chromium, cobalt, copper and silicon contents in ferronickel. The content ranges of the determined elements are shown in Table 1.
The silicon measured by this method is acid-soluble silicon. Table 1 - Content Ranges of the Determined Elements. Its clauses include principle; reagents; instrument; sampling and sample preparation; analysis procedures; calculation of results; precision; expression of analysis results; test report.
It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on OCTOBER 30, 2009 and took effect on MAY 01, 2010.
Found what you need?
Document preview — GB/T 24585-2009
National Standard of the People's Republic of China
- ICS
- 77.100
- Classification
- H 11
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative References4
- 3 Principle5
- 4 Reagents5
- 5 Instrument7
- 6 Sampling and Sample Preparation9
- 7 Analysis Procedures9
- 8 Calculation of Results11
- 9 Precision13
- 10 Expression of Analysis Results13
- 11 Test Report14
- Appendix A (Normative) Performance Test for the Detection Limit (DL) and the Background Equivalent Concentration (BEC) of the Inductively Coupled Plasma Spectrometer15
- Appendix B (Normative) Standardization of Calibration Curve (Drift Correction)18
Foreword
The Appendixes A and B in this Standard are normative.
1 Scope
This Standard specifies the use of inductively coupled plasma atomic emission spectrometric method (ICP-AES) to determine the contents of phosphorus, manganese, chromium, cobalt, copper and silicon.
This Standard is applicable to the determination of phosphorus, manganese, chromium, cobalt, copper and silicon contents in ferronickel. The content ranges of the determined elements are shown in Table 1. The silicon measured by this method is acid-soluble silicon.
2 Normative References
The provisions in following documents become the provisions of this Standard through reference in this Standard. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard,
GB/T 4010 Ferroalloys Sampling and Preparation of Samples for Chemical Analysis
GB/T 6379.1 Accuracy (Trueness and Precision) of Measurement Methods and Results - Part 1: General Principles and Definitions (GB/T 6379.1-2004, ISO 5725-1:1994, IDT)
GB/T 6379.2 Accuracy (Trueness and Precision) of Measurement Methods and Results - Part 2: Basic Method for the Determination of Repeatability and Reproducibility of a Standard Measurement Method
GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods
GB/T 20066 Steel and Iron - Sampling and Preparation of Samples for the Determination of Chemical Composition
3 Principle
The testing material is decomposed by nitric acid and hydrochloric acid. The testing material with high carbon or high silicon content is added with hydrofluoric acid to help dissolving. When perchloric acid emits smoke, it shall expel silicon and fluorine completely.
4 Reagents
Unless otherwise specified, only guaranteed reagents and laboratory water complying with the provisions of GB/T 6682 are used in the analysis process.
4.1 High purity nickel, the content of the element to be tested is less than 0.001% (mass fraction).
4.2 High purity iron, the content of the element to be tested is less than 0.001% (mass fraction).
4.3 Hydrochloric acid, rho is about 1.19g/mL
4.8 Standard stock solution
4.8.1 Phosphorus standard solution, 1000µg/mL
Take 4.3936g of reference dipotassium hydrogen phosphate dried at 105°C ~ 110°C; dissolve it in an appropriate amount of water; transfer it into a 1000 mL volumetric flask; dilute to the mark with water; and mix evenly. 1mL of this solution contains 1000µg of phosphorus.
4.8.4 Cobalt standard solution, 1000µg/mL
Take 1.0000g of high-purity cobalt powder (content is greater than 99.9%) in a 600mL beaker; then add 40mL of nitric acid (4.5); cover with a watch glass; heat it to completely dissolve it; slightly boil to discharge nitrogen oxides; cool to room temperature; transfer to a 1000 mL volumetric flask containing 160 mL of nitric acid (4.5); dilute to the mark with water; and mix evenly. 1mL of this solution contains 1000µg of cobalt.
4.8.6 Silicon standard solution, 1000µg/mL
After the high-purity silica (content is greater than 99.9%) is sintered to its constant weight at a temperature of 1100°C, it is cooled to room temperature in a desiccator; and take 2.1393g of it into a platinum crucible; and add about 10g of anhydrous sodium carbonate; heated to melting for 15min.
4.8.7 Phosphorus standard solution, 250µg/mL
Pipette 25.00mL of phosphorus standard solution (4.8.1) in a 100mL volumetric flask; dilute to the mark with water; and mix evenly. 1mL of this solution contains 250µg of phosphorus.
4.8.8 Copper, silicon and phosphorus mixed standard solution
Pipette 25.00mL of copper standard solution (4.8.5), 50.00mL of silicon standard solution, (4.8.6) and 20.00mL of phosphorus standard solution (4.8.7), respectively in a 100mL volumetric flask; dilute to the mark with nitric acid (4.5); and mix evenly. 1mL of this solution contains copper, silicon and phosphorus of 250µg, 500µg and 50µg, respectively.
5 Instrument
5.1 Inductively coupled plasma (ICP) spectrometer
After the spectrometer is optimized according to 7.4.1 ~ 7.4.5 and satisfies the performance indicators of 5.1.2 ~ 5.1.5, then it meets the requirements for use. The spectrometer may be either simultaneous or sequential.
5.1.1 Analysis line
This Standard does not specify a special analysis line, the recommended analysis line is listed in Table 2. When in use, carefully check the interference of the spectral lines.
5.1.4 Long-term stability
Determine the average value of the absolute intensity of the standard calibration solution with the highest concentration of each element for 3 times; and calculate the standard deviation of the 7 average values. The relative standard deviation shall be less than 2.0%.
5.1.5 Background equivalent concentration and detection limit (see Appendix A)
Determine according to Appendix A; calculate the background equivalent concentration and detection limit, the result must be lower than the value in Table 3.
5.1.6 Linearity of the curve
Analysis Elements Wavelength / nm Possible interference spectral line / nm
6 Sampling and Sample Preparation
It shall be performed according to the provisions of GB/T 4010 and GB/T 20066.
7 Analysis Procedures
7.1 Amount of testing material
Take 0.50g of testing material, accurate to 0.0001g.
7.2 Blank test
Do a blank test with the testing material. The blank test shall use pure nickel (4.1) and pure iron (4.2) equivalent to the amount of nickel and iron in the testing material to replace the testing material.
7.3 Determination
7.3.1 Preparation of testing material solution
7.3.2 Preparation of calibration curve solution
Replace the testing material with pure nickel (4.1) and pure iron (4.2) equivalent to the amount of nickel and iron in the testing material. Follow the operation procedures in 7.3.1.1. Before the final dilution to 100mL, add the standard solutions according to Table 4, then dilute to the mark with water and mix evenly.
7.4 Spectral measurement
7.4.1 Optimization of the instrument
Turn on the inductively coupled plasma (ICP) spectrometer, and run it for at least 1h before measuring.
7.4.2 Measurement of emission intensity
7.4.2.1 Measurement of calibration solution
First use the zero-concentration calibration solution; and inhale the calibration solution in order of increasing concentration; and inhale deionized water between each inhalation of the solution. Repeat the measurement for at least 2 times, and take the average of the 2 readings.
7.5 Correction of interference line in analysis line
First check the spectral interference of each coexisting element on the analysis line of the measured element.
7.6 Drawing of calibration curve
Do the linear regression with the net intensity as the Y-axis and the concentration of the measured element (µg/mL) as the X-axis. The calculation of the correlation coefficient shall meet the requirements of 5.1.6.
8 Calculation of Results
8.1 According to the calibration curve (7.6), the spectral intensity of the test solution is calculated to the concentration of the corresponding element to be measured, expressed in µg/mL.
8.2 Correction of spectral interference
It is recommended to use synthetic standard solution as a correction method for spectral interference, the procedure is as follows. […]
9 Precision
The precision of this Standard is jointly tested by 8 laboratories; and is determined by statistical analysis in accordance with the provisions of GB/T 6379.1 and GB/T 6379.2. The precision is shown in Table 5.
10 Expression of Analysis Results
The analysis result is the average value of the results of 2 independent analyses; and the analysis result retains 2 significant figures after the decimal point.
11 Test Report
The test report shall include the following. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 4010Ferroalloys sampling and preparation of samples for chemical analysis
- GB/T 6379.1Accuracy (trueness and precision) of measurement methods and results -- Part 1: General principles and definitions
- GB/T 6379.2Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
- GB/T 6682Water for analytical laboratory use - Specification and test methods
- GB/T 20066Steel and iron -- Sampling and preparation of samples for the determination of chemical composition
Similar standards
How to Download GB/T 24585-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards