Valid

GB/T 24392-2009Standard method of measurement of lamp cap temperature rise (English PDF)

灯头温升的测量方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (9 pages)

Need quotation for your management?

Get a formal quotation for GB/T 24392-2009 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

September 30, 2009

Implementation date

February 1, 2010

Scope

GB/T 24392-2009 is the English-translated version of 灯头温升的测量方法.

GB/T 24392-2009 — Standard measurement method described in this standard cap temperature rise, suitable for detecting tungsten and gas discharge lamps meets the temperature rise limit.

GB 14196 are listed lamp type temperature limit. This standard relates to the technical requirements and test methods for test lamp base of the lamp, this type of lamp is equipped with different types of screw caps and bayonet lamp head.

This method has been widely used to test the incandescent lamp, but its use is not limited to incandescent lamps.

Found what you need?

Document preview — GB/T 24392-2009

National Standard of the People's Republic of China

ICS
29.140.10
Classification
K 74

Issued by: Standardization Administration of China

Contents

  • Preface
  • Introduction
  • 1 Overview
  • 1.1 Scope
  • 1.2 Normative references
  • 2 Definitions
  • 2.1 1 cap temperature rise
  • 2.2 Equilibrium temperature
  • General conditions for measurement of 3
  • 3.1 Aging and stability
  • 3.2 Supply Voltage
  • 3.3 Test chamber at ambient temperature and the reference temperature
  • 4 2 test requirements
  • 4.1 Test Chamber
  • 4.2 Method 2 suspension
  • 5 Test lamp socket
  • 5.1 General structure
  • 5.2 Test lampholder sleeve material requirements
  • 5.3 Spring material claim
  • 6 Power Wire
  • Thermocouple 7
  • 7.1 Material
  • 7.2 Connection
  • 7.3 Test connection with lamp holder sleeve
  • 7.4 Instrument
  • 7.5 Calibration
  • 8 Lamp and lamp holder installation test in the chamber of
  • 9 Measuring cap temperature rise of

Foreword

This standard is identical with IEC 60360:1998 "Measurement cap temperature rise" (in English).

This standard is equivalent translation IEC 60360:1998.

For ease of use, this standard made the following editorial changes.

a) "The technical specifications" replaced by "this standard";

b) Remove IEC 60360:1998 Foreword;

c) For IEC 60360:1998 and other international standards have been cited as identical with our standard, our present standard reference these national standards or industry standards corresponding to international standards in place, the rest is not tantamount to the adoption of standard international standards, this standard are a direct reference (see 1.2 of this standard).

The standard proposed by China National Light Industry Council.

This standard by the National Standardization Technical Committee of electrical lighting (SAC/TC224) centralized.

This standard was drafted. Zhejiang Institute of Standardization, Beijing Institute of electric light.

Introduction

Cap temperature rise depends largely on the lamp assembly and lamp conditions. Accordingly, it is necessary to test the lamp holder according to the criteria used Compared with bare measuring cap temperature rise, the temperature rise measured standard test lampholder, has the following advantages.

--- Closest to the actual operating conditions;

--- Improving the repeatability, due to the smaller cap material, surface roughness and surface conditions on (lamp material, surface roughness and surface the same conditions of actual operating conditions less affected);

--- All parts of the lamp cap temperature equilibrium, given from a light fixture to a more complete overall heat transfer;

--- Shorten the measurement time, because the thermocouple can be permanently fixed to the test holder.

GB/T 24392-2009/IEC 60360:1998 the method of measuring cap temperature rise

1 Overview

1.1 Scope

Standard measurement method described in this standard cap temperature rise, suitable for detecting tungsten and gas discharge lamps meets the temperature rise limit.

GB 14196 are listed lamp type temperature limit.

This standard relates to the technical requirements and test methods for test lamp base of the lamp, this type of lamp is equipped with different types of screw caps and bayonet lamp head. This method has been widely used to test the incandescent lamp, but its use is not limited to incandescent lamps.

1.2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB 14196 (all parts) incandescent safety requirements (IEC 60432, IDT)

2 Definitions

This standard uses the following terms and definitions.

Under the conditions specified in this standard, the standard test lampholder fitted cap measured surface temperature rise.

After fully lighted lamp, a standard test lampholder reached steady-state temperature.

Note. The measurement accuracy should be ± 1 °C.

3 General Condition, of Measurement

3.1 Aging and stability

Before measurement, the lamp does not have to be old mill. When the equilibrium temperature test chamber, the lamp should reach full stability.

3.2 Supply Voltage

a) directly connected to the power supply of the lamp, when measured using the rated voltage, the power supply voltage should be stabilized in the range of ± 0.5%;

b) by the power supply is connected to the ballast lamp ballast should be measured using the rated voltage of the power supply voltage should be stable at ± 0.5% in the range. This should be measured using a reference ballast or ballast finished, with a reference ballast impedance in current calibration Ballast error should be within ± 1% range.

If the lamp voltage range marker should be used in the test procedures specified in GB 14196, other publications as otherwise provided by the program except.

3.3 Test chamber at ambient temperature and the reference temperature

Except provisions), namely. the test chamber temperature during the measurement should be kept within this range in order to ensure effective measurement results. Measurements taken 4.1 with a special chamber, wherein the chamber to ensure that the ambient temperature reaches substantially constant.

GB/T 24392-2009/IEC 60360:1998

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 24392-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
9 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 24392-2009

$205.00