Scope

GB/T 23901.4-2019 is the English-translated version of 无损检测 射线照相检测图像质量 第4部分:像质值和像质表的实验评价.

GB/T 23901.4-2019 — This Part of GB/T 23901 gives instructions for the determination of image quality values and image quality tables. This Part applies to the experimental evaluation of image quality values and image quality tables during radiographs.

If the IQI requirements specified in GB/T 23901.3 cannot be used because, for example, the absorption coefficients of the IQI material and the inspected material differ by more than 30 %, test exposures are necessary to determine acceptance of image quality values.

The image quality values achieved by the test exposures are suitable for testing the object under the same radiographic conditions.

Found what you need?

Document preview — GB/T 23901.4-2019

National Standard of the People's Republic of China

Issued by: SAMR; SAC

Contents

  • Foreword...3
  • 1 Scope...5
  • 2 Terms and definitions...5
  • 3 Experimental evaluation of image quality values...6
  • 4 Determination of image quality tables...6
  • Bibliography...8

Foreword

GB/T 23901 "Non-destructive testing - Image quality of radiographs" is divided

into 5 parts:

- Part 1: Determination of the image quality value using wire-type image

quality indicators;

- Part 2: Determination of the image quality value using step/hole-type image

quality indicators;

- Part 3: Image quality classes;

- Part 4: Experimental evaluation of image quality values and image quality

tables;

- Part 5: Determination of the image quality unsharpness and basic spatial

resolution value using duplex wire-type image quality indicators.

This Part is Part 4 of GB/T 23901.

This Part is drafted in accordance with the rules given in GB/T 1.1-2009.

This Part replaces GB/T 23901.4-2009 "Non-destructive testing - Image quality

of radiographs - Part 4: Experimental evaluation of image quality values and

image quality tables". As compared with GB/T 23901.4-2009, the main changes

are as follows:

- Delete normative references (See Clause 2 of the 2009 edition);

- Modify terms and definitions (See Clause 2; Clause 3 of the 2009 edition);

- Modify Figure 1 and the corresponding key;

- CHANGE the expression in Chinese of "Image quality of radiographs"

[Translator note: There is another expression for "Image quality of

radiographs" in Chinese].

This Part, using translation method, is identical to ISO 19232-4:2013 "Non-

destructive testing - Image quality of radiographs - Part 4: Experimental

evaluation of image quality values and image quality tables".

This Part was proposed by and shall be under the jurisdiction of National

Technical Committee 56 on Non-destructive Testing of Standardization

Administration of China (SAC/TC 56).

Drafting organizations of this Part: Shanghai Aerospace Power Technology

Engineering Co., Ltd.; Shanghai Institute of Space Propulsion; Shanghai

Research Institute of Materials; Zhejiang Jinyun IQI. Co.; Matrix Science and

Industry Testing Technologies (Beijing) Co., Ltd.; Hubei Sanjiang Space

Jiangbei Machinery Engineering Co., Ltd.; China Nuclear Power Engineering

Co., Ltd.; Shanghai Spaceflight Precision Machinery Institute; Shanghai

Institute of Spacecraft Equipment; Shanghai Aerospace Equipment

Manufacturer Co., Ltd.; Shanghai Acoustics Laboratory, Chinese Academy of

Sciences; Sichuan Aerospace Chuannan Fire Work Technology Co., Ltd.;

Zhejiang Academy of Special Equipment Science; Aerospace Research

Institute of Materials & Processing Technology; Ningbo Special Equipment

Inspection and Research Institute; CITIC Dicastal Co., Ltd.; Shanghai

Aerospace Control Technology Institute; NDT Testing Technology (Shanghai)

Co., Ltd.

Main drafters of this Part: Xu Guozhen, Chen Yiwei, Jiang Jiansheng, Ding Jie,

Liu Zhanglong, Jiang Yunxi, Wang Xiaoyong, Zhu Congbin, Zhou Jianping, Wei

Quan, Sun Jiangang, Xu Wei, Hu Ling, Zhang Zheng, Huang Wenda, Lv Yanda,

Yuan Shengping, Chen Hu, Liu Jun, Yuan Zhizuo, Zhang Rui, Zhang Yifeng,

Zhai Lianna, Ma Jun.

The previous editions of the standard replaced by this Part were released as

follows:

- GB/T 23901.4-2009.

Non-destructive testing - Image quality of radiographs

- Part 4: Experimental evaluation of image quality

values and image quality tables

1 Scope

This Part of GB/T 23901 gives instructions for the determination of image quality

values and image quality tables.

This Part applies to the experimental evaluation of image quality values and

image quality tables during radiographs. If the IQI requirements specified in

GB/T 23901.3 cannot be used because, for example, the absorption coefficients

of the IQI material and the inspected material differ by more than 30 %, test

exposures are necessary to determine acceptance of image quality values. The

image quality values achieved by the test exposures are suitable for testing the

object under the same radiographic conditions.

2 Terms and definitions

For the purposes of this document, the following terms and definitions apply.

2.1 Image quality indicator; IQI

Device comprising a series of wires or steps with holes of graded dimensions

which enable a measure of the image quality to be obtained.

Note: Image quality indicator may also be expressed in terms of IQI [Translator note: There

is additional 1 name in Chinese]. The type of image quality indicator is usually a wire-

type or a step/hole-type.

2.2 Image quality

Characteristic of a radiographic image which determines the degree of detail

which it shows.

2.3 Image quality value

Measure of the image quality required or achieved and is equal to the finest

wire or smallest hole which can be detected on the radiograph.

Note: Image quality value may also be expressed in terms of IQI sensitivity [Translator

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

How to Download GB/T 23901.4-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 23901.4-2019

$85.00