GB/T 23901.4-2019Non-destructive testing -- Image quality of radiographs -- Part 4: Experimental evaluation of image quality values and image quality tables (English PDF)
Also coversGBT23901.4-2019
Open the GB/T 23901.4-2019 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
June 4, 2019
Implementation date
January 1, 2020
Scope
GB/T 23901.4-2019 (Non-destructive testing -- Image quality of radiographs -- Part 4: Experimental evaluation of image quality values and image quality tables) is available as an English-translated PDF.
GB/T 23901.4-2019 — This Part of GB/T 23901 gives instructions for the determination of image quality values and image quality tables. This Part applies to the experimental evaluation of image quality values and image quality tables during radiographs. If the IQI requirements specified in GB/T 23901.3 cannot be used because, for example, the absorption coefficients of the IQI material and the inspected material differ by more than 30 %, test exposures are necessary to determine acceptance of image quality values. The image quality values achieved by the test exposures are suitable for testing the object under the same radiographic conditions.
Document preview — GB/T 23901.4-2019
National Standard of the People's Republic of China
Issued by: SAMR; SAC
Contents
- Foreword...3
- 1 Scope...5
- 2 Terms and definitions...5
- 3 Experimental evaluation of image quality values...6
- 4 Determination of image quality tables...6
- Bibliography...8
Foreword
GB/T 23901 "Non-destructive testing - Image quality of radiographs" is divided
into 5 parts:
- Part 1: Determination of the image quality value using wire-type image
quality indicators;
- Part 2: Determination of the image quality value using step/hole-type image
quality indicators;
- Part 3: Image quality classes;
- Part 4: Experimental evaluation of image quality values and image quality
tables;
- Part 5: Determination of the image quality unsharpness and basic spatial
resolution value using duplex wire-type image quality indicators.
This Part is Part 4 of GB/T 23901.
This Part is drafted in accordance with the rules given in GB/T 1.1-2009.
This Part replaces GB/T 23901.4-2009 "Non-destructive testing - Image quality
of radiographs - Part 4: Experimental evaluation of image quality values and
image quality tables". As compared with GB/T 23901.4-2009, the main changes
are as follows:
- Delete normative references (See Clause 2 of the 2009 edition);
- Modify terms and definitions (See Clause 2; Clause 3 of the 2009 edition);
- Modify Figure 1 and the corresponding key;
- CHANGE the expression in Chinese of "Image quality of radiographs"
[Translator note: There is another expression for "Image quality of
radiographs" in Chinese].
This Part, using translation method, is identical to ISO 19232-4:2013 "Non-
destructive testing - Image quality of radiographs - Part 4: Experimental
evaluation of image quality values and image quality tables".
This Part was proposed by and shall be under the jurisdiction of National
Technical Committee 56 on Non-destructive Testing of Standardization
Administration of China (SAC/TC 56).
Drafting organizations of this Part: Shanghai Aerospace Power Technology
Engineering Co., Ltd.; Shanghai Institute of Space Propulsion; Shanghai
Research Institute of Materials; Zhejiang Jinyun IQI. Co.; Matrix Science and
Industry Testing Technologies (Beijing) Co., Ltd.; Hubei Sanjiang Space
Jiangbei Machinery Engineering Co., Ltd.; China Nuclear Power Engineering
Co., Ltd.; Shanghai Spaceflight Precision Machinery Institute; Shanghai
Institute of Spacecraft Equipment; Shanghai Aerospace Equipment
Manufacturer Co., Ltd.; Shanghai Acoustics Laboratory, Chinese Academy of
Sciences; Sichuan Aerospace Chuannan Fire Work Technology Co., Ltd.;
Zhejiang Academy of Special Equipment Science; Aerospace Research
Institute of Materials & Processing Technology; Ningbo Special Equipment
Inspection and Research Institute; CITIC Dicastal Co., Ltd.; Shanghai
Aerospace Control Technology Institute; NDT Testing Technology (Shanghai)
Co., Ltd.
Main drafters of this Part: Xu Guozhen, Chen Yiwei, Jiang Jiansheng, Ding Jie,
Liu Zhanglong, Jiang Yunxi, Wang Xiaoyong, Zhu Congbin, Zhou Jianping, Wei
Quan, Sun Jiangang, Xu Wei, Hu Ling, Zhang Zheng, Huang Wenda, Lv Yanda,
Yuan Shengping, Chen Hu, Liu Jun, Yuan Zhizuo, Zhang Rui, Zhang Yifeng,
Zhai Lianna, Ma Jun.
The previous editions of the standard replaced by this Part were released as
follows:
- GB/T 23901.4-2009.
Non-destructive testing - Image quality of radiographs
- Part 4: Experimental evaluation of image quality
values and image quality tables
1 Scope
This Part of GB/T 23901 gives instructions for the determination of image quality
values and image quality tables.
This Part applies to the experimental evaluation of image quality values and
image quality tables during radiographs. If the IQI requirements specified in
GB/T 23901.3 cannot be used because, for example, the absorption coefficients
of the IQI material and the inspected material differ by more than 30 %, test
exposures are necessary to determine acceptance of image quality values. The
image quality values achieved by the test exposures are suitable for testing the
object under the same radiographic conditions.
2 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
2.1 Image quality indicator; IQI
Device comprising a series of wires or steps with holes of graded dimensions
which enable a measure of the image quality to be obtained.
Note: Image quality indicator may also be expressed in terms of IQI [Translator note: There
is additional 1 name in Chinese]. The type of image quality indicator is usually a wire-
type or a step/hole-type.
2.2 Image quality
Characteristic of a radiographic image which determines the degree of detail
which it shows.
2.3 Image quality value
Measure of the image quality required or achieved and is equal to the finest
wire or smallest hole which can be detected on the radiograph.
Note: Image quality value may also be expressed in terms of IQI sensitivity [Translator
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
How to Buy GB/T 23901.4-2019
- 1Add to cart. Click the "Buy GB/T 23901.4-2019" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 23901.1-2019 — Non-destructive testing -- Image quality of radiographs -- Part 1: Determination of the image quality value using wire-type image quality indicators
GB/T 23901.2-2019 — Non-destructive testing -- Image quality of radiographs -- Part 2: Determination of the image quality value using step/hole-type image quality indicators
GB/T 23901.3-2019 — Non-destructive testing -- Image quality of radiographs -- Part 3: Image quality classes
Secure payment via Stripe
Payments accepted
GB/T 23901.4-2019