GB/T 21198.3-2007Determination of precious metals in precious metals jewellery alloys -- Method using ICP spectrometry -- Part 3: Palladium jewellery alloys -- Determination of palladium -- Method using a solution with yttrium as internal standard element (English PDF)
贵金属合金首饰中贵金属含量的测定 ICP光谱法 第3部分:钯合金首饰 钯含量的测定 采用钇为内标
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for GB/T 21198.3-2007 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
November 12, 2007
Implementation date
July 1, 2008
Scope
GB/T 21198.3-2007 is the English-translated version of 贵金属合金首饰中贵金属含量的测定 ICP光谱法 第3部分:钯合金首饰 钯含量的测定 采用钇为内标.
GB/T 21198.3-2007 — This section GB/T 21198 specifies the determination of yttrium to palladium jewelery alloys palladium content of the internal standard method using ICP spectroscopy.
This section applies to a palladium content of 475 per mille ~ 970 per mille palladium alloy jewelry. NOTE. palladium jewelery alloys may contain silver, indium, gallium, copper, cobalt, nickel, tin, ruthenium.
Containing these alloying elements in the determination process generally do not cause interference.
Found what you need?
Document preview — GB/T 21198.3-2007
National Standard of the People's Republic of China
- ICS
- 39.060
- Classification
- Y 88
Issued by: Standardization Administration of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 PRINCIPLE OF THE METHOD
- 4 Reagent material
- 5 Instruments
Foreword
GB/T 21198 "precious metal jewelery alloys precious metal content using ICP spectrometry" is divided into six parts.
--- Part 1. Determination of platinum content platinum jewelery alloys using yttrium as internal standard;
--- Part 2. Determination of platinum content platinum alloy jewelry using platinum all trace elements and the intensity ratio method;
--- Part 3. Determination of palladium jewelery alloys using palladium content of yttrium as internal standard;
--- Part 4. Determination of 999 per mille precious metal jewelery alloys precious metal content of subtraction;
Part --- Article 5. 999 per mille silver jewelery alloys - Determination of silver content difference of subtraction;
--- Part 6. Subtraction.
This section GB/T 21198 Part 3.
The section referring to ISO/DIS11495-2.2001 "Determination of palladium in palladium jewelery alloys for the content of yttrium as internal standard using ICP spectroscopy" Write, there are mainly ISO/DIS11495-2 the following technical differences.
--- The Normative references to international standards referenced in the file to our national standard GB 11887;
--- According to our standard requirements for the preparation of reagents specifications made provisions;
--- Since the standard is not covered microbalance, resulted in the removal of the original 5.2 "microbalance, it can be said to 0.001mg";
--- Due to the current international and domestic no standard for sample preparation, thus deleting the original text of Chapter 6 and Chapter 9 b).
For ease of use, this section also made the following editorial changes.
--- "This International Standard" be replaced by "this section";
"." --- With a decimal point instead of a comma as the decimal point, "";
--- With "mL" instead of "cm3";
--- Delete international standards foreword.
This part is proposed by the China National Light Industry Council.
This part of the National Standardization Technical Committee jewelry (SAC/TC256) centralized.
This section drafted by. National Jewelry Quality Supervision and Inspection Center.
1 Scope
This section GB/T 21198 specifies the determination of yttrium to palladium jewelery alloys palladium content of the internal standard method using ICP spectroscopy.
This section applies to a palladium content of 475 per mille ~ 970 per mille palladium alloy jewelry.
NOTE. palladium jewelery alloys may contain silver, indium, gallium, copper, cobalt, nickel, tin, ruthenium. Containing these alloying elements in the determination process generally do not cause interference.
2 Normative references
The following documents contain provisions which, through reference GB/T 21198 in this section constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
GB 11887 jewelry precious metal purity and designation of (GB 11887-2002, ISO 9202:1991, NEQ)
3 PRINCIPLE OF THE METHOD
Accurately weighed sample was dissolved in aqua regia and made accurate quality solution. The sample solution was prepared quantitatively solution aliquot, and the buffer Mixing the solution and the internal standard, calibration standard to measure the volume.
Application of ICP spectrometer, the sample solution of palladium (340.45nm) and yttrium (371.03nm) spectral intensity ratio diverging containing known Quality ratio of platinum and yttrium solution comparison, measuring the content of palladium.
4 Reagent material
Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity.
4.1 Hydrochloride. mass fraction of 36% ~ 38%, rho = 1.19g/mL.
4.2 nitric acid. mass fraction of 65% ~ 68%, rho = 1.40g/mL.
4.3 pure palladium. content of at least 99.99%.
4.4 Internal standard solution. Weigh 26.8g copper dihydrate (CuCl2 · 2H2O) chloride, 7.3g sodium nitrate (NaNO3) and about 680mg Six Rivers Co-yttrium chloride (YCl3 · 6H2O) was dissolved in 200mL of water, water calibration to 1000mL.
5 Instruments
Conventional laboratory instruments and equipment following
5.1 Inductively coupled plasma atomic emission spectroscopy (ICP spectrometer for short). the transmission line can be determined 340.45nm palladium and yttrium internal standard at the same time Intensity of emission lines 371.03nm.
Spectrometry results are more satisfied with the following characteristics.
--- Reversible linear dispersion. 0.5nm/mm;
--- Optical resolution. 0.02nm;
--- High frequency power. 1.2kW;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
Referenced standards
How to Download GB/T 21198.3-2007
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 11887-2012 — Jewellery -- Fineness of precious metal alloys and designation [including MODIFICATION 1]
GB/T 21198.1-2007 — Determination of precious metals in precious metals jewellery alloys -- Method using ICP spectrometry -- Part 1: Platinum jewellery alloys -- Determination of platinum -- Method using a solution with yttrium as internal standard element
GB/T 21198.2-2007 — Determination of precious metals in precious metals jewellery alloys -- Method using ICP spectrometry -- Part 2: Platinum jewellery alloys -- Determination of platinum -- Method using the intensity ratios of all minor constituents with reference to platin
Secure payment via Stripe
Payments accepted
GB/T 21198.3-2007
$165.00