GB/T 20975.28-2019Methods for chemical analysis of aluminium and aluminium alloys—Part 28:Determination of cobalt content—Flame atomic absorption spectrometry (English PDF)
铝及铝合金化学分析方法 第28部分:钴含量的测定 火焰原子吸收光谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 20975.28-2019 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
June 4, 2019
Implementation date
May 1, 2020
Scope
GB/T 20975.28-2019 is the English-translated version of 铝及铝合金化学分析方法 第28部分:钴含量的测定 火焰原子吸收光谱法.
GB/T 20975.28-2019 is Part 28 of the Chinese methods for the chemical analysis of aluminium and aluminium alloys and determines cobalt content by flame atomic absorption spectrometry.
The test material is dissolved in hydrochloric and nitric acid, and the absorbance of cobalt is measured in an air-acetylene flame at 240.7 nm.
It sets out the reagents and apparatus, the preparation of the sample into chips of no more than 1 mm, the analysis steps from the 0.20 g test portion and the blank test, the calculation of the mass fraction, the precision, the quality assurance and control, and the test report.
It applies to aluminium, aluminium alloys and aluminium-cobalt master alloy over the range 0.005% to 12.0%, and cites GB/T 6682 and GB/T 8170-2008. It was issued on 4 June 2019 and has applied since 1 May 2020.
Found what you need?
Document preview — GB/T 20975.28-2019
National Standard of the People's Republic of China
- ICS
- 77.120.10
- Classification
- H 12
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope6
- 2 Normative references6
- 3 Method summary6
- 4 Reagents7
- 5 Apparatus7
- 6 Sample8
- 7 Analysis steps8
- 8 Calculation of analysis result10
- 9 Precision10
- 10 Quality assurance and control11
- 11 Test report11
1 Scope
This Part of GB/T 20975 specifies the method of flame atomic absorption spectrometry to determine cobalt content in aluminium and aluminium alloys.
This Part is applicable to determination of cobalt content in aluminum and aluminum alloy, aluminum-cobalt intermediate alloy. Determination range: 0.005%~12.0%.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 6682, Water for analytical laboratory use - Specification and test methods
GB/T 8170-2008, Rules of rounding off for numerical values & expression and judgement of limiting values
3 Method summary
Use hydrochloric acid, nitric acid to dissolve test material. In dilute acid medium, at the wavelength of 240.7nm of atomic absorption spectrometer, in air-acetylene flame, measure absorbance of cobalt so as to determine cobalt content.
5 Apparatus
standard deviation shall not exceed 0.5% of average absorbance of highest-concentration standard solution.
- Working curve linear: Divide working curve into five segments according to concentration. The ratio of difference between absorbance of the highest segment and absorbance of the lowest segment shall be not less than 0.80.
6 Sample
Process sample into chips of no more than 1mm.
7 Analysis steps
7.1 Test material
Weigh a sample of which mass (m) is 0.20g (see Clause 6), to the nearest of 0.0001g.
7.2 Number of determination
Perform two determinations independently. Take the average value.
7.3 Blank test
Weigh 0.20g of aluminum (4.1) to replace test material (7.1). Carry out blank test with test material.
7.4 Determination
7.4.1 Place test material (7.1) into a 100mL beaker. Add into 10mL of hydrochloric acid (4.5). After violent reaction stops, heat until test material is dissolved. Add few drops of nitric acid (4.6). Boil to remove nitrogen oxide. Cool.
Move into a 100mL volumetric flask. Use water to dilute to scale. Set volume (V). Mix well.
NOTE: If there is insoluble matter, filtrate and wash. Place residue together with filter paper in a platinum crucible. Perform ashing (do not let filter paper burn). Burn at about 550°C.
Cool. Add 5mL of hydrofluoric acid (4.4). And add into hydrochloric acid (4.5) drop by drop till solution is clear. Heat to evaporate to dry. Burn at 700°C for several minutes. Cool. Use hydrochloric acid (4.5) as little as possible to dissolve residue. Combine this filtrate in stock solution.
7.4.2 According to Table 1, distribute test solution in a suitable volumetric flask.
Add into hydrochloric acid (4.5). Use water to dilute to scale. Mix well for testing.
8 Calculation of analysis result
8.1 Cobalt content is calculated in mass fraction of cobalt w(Co). Calculate according to formula (1):
Where, rho - Mass concentration of cobalt in analysis solution found on working curve, in micrograms per milliliter (µg/mL);
rho0 - Mass concentration of cobalt in blank solution found on working curve, in micrograms per milliliter (µg/mL); V - Set volume of test solution, in milliliters (mL);
T - Dilution factor; m - Mass of test material, in grams (g).
8.2 When cobalt content is < 0.10%, calculation result is expressed to three decimal places. When cobalt content is >=0.10%, calculation result is expressed to two decimal places. Numerical rounding-off is carried out according to 3.2 and 3.3 in GB/T 8170-2008.
9 Precision
9.1 Repeatability
Obtain measured values of two independent test results under repeatability conditions. Within the range of average values given below, the absolute difference between two test results does not exceed the repeatability limit r.
When it exceeds the repeatability limit r, it shall not exceed 5%. Repeatability limit r is obtained by linear interpolation according to data in Table 2. […]
9.2 Reproducibility
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 20975.28-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-1992 — Water for analytical laboratory use--Specification and test methods
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 8170-2008 — Rules of rounding off for numerical values & expression and judgement of limiting values
GB/T 20975.28-2019
$75.00