GB/T 20841-2025Heating cables with a rated voltage up to and including 300/500 V for comfort heating and prevention of ice formation (English PDF)

额定电压300/500V及以下生活设施加热和防结冰用加热电缆

Preview PDF

This is a limited preview

Buy now to download the full PDF (19 pages)

Need quotation for your management?

Get a formal quotation for GB/T 20841-2025 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Recommended

Issue date

October 5, 2025

Implementation date

May 1, 2026

Scope

GB/T 20841-2025 is the English-translated version of 额定电压300/500V及以下生活设施加热和防结冰用加热电缆.

GB/T 20841-2025 — This document applies to resistance heating cables used in low-temperature environments, such as for heating domestic facilities and preventing icing.

Heating cables and heating... Cable assemblies consist of component units assembled in the factory or on-site according to the manufacturer's instructions. Bare conductors and protected conductors with a supply voltage of 50V or less are not included in the scope of this document.

Typical applications include, but are not limited to. ---Heating devices installed inside or under the surface; ---Direct and storage heating; --- Snow melting and frost protection for roofs, gutters, and pipes.

Resistance heating systems, such as mineral-insulated heating cables, are described in detail in the IEC 62395 series of standards for industrial and commercial applications.

The application of explosive atmospheres is detailed in the IEC/IEEE 60079-30 series of standards. Applications with sheaths operating at temperatures exceeding 100°C are not covered by this document.

The purpose of this document is to ensure the safe operation of heating cables under normal, specified operating conditions.

This is achieved through the following methods. ---Use heating cables of appropriate construction that meet the test requirements described in this document; ---Including heating cables with electrical protection components, featuring a metal braided structure, concentric conductors or sheath, or other suitable conductive materials.

Materials for protection in the event of a failure; ---The construction and installation materials for heating cables should comply with national regulations to ensure that the heating cables operate at safe temperatures.

Found what you need?

Document preview — GB/T 20841-2025

National Standard of the People's Republic of China

ICS
29.060.20
Classification
K 13
Replacing
GB/T 20841-2007

Issued by: State Administration for Market Regulation

Contents

  • Preface
  • 1 Scope
  • 2 Normative References
  • 3 Terms and Definitions
  • 4 Mechanical grade
  • 5 Labeling Requirements
  • 6 Installation Instructions Required
  • 7 General requirements for heating cable structure 6.
  • 7.1 General Rules
  • 7.2 Conductor
  • 7.3 Insulation
  • 7.4 Conductive Shielding
  • 7.5 Armor
  • 7.6 Sheath
  • 7.7 Moisture resistance
  • 8 Experiment
  • 8.1 Type Testing – General Requirements
  • 8.2 Type Testing – Detailed Test Requirements
  • 8.2.1 Resistance of heating conductor and shield
  • 8.2.2 Immersion and Temperature Cycling Test
  • 8.2.3 Verification of rated output of parallel heating cables
  • 8.2.4 Verification of the starting current of parallel heating cables
  • 8.2.5 Conductive Shielding Penetration Test
  • 8.2.6 Flammability Test
  • 8.2.7 Installation Classification Deformation Test
  • 8.2.8 Low-temperature impact test
  • 8.2.9 Low-temperature bending test
  • 8.2.10 Insulation aging test
  • 8.2.11 Aging test of non-metallic sheath
  • 8.2.12 Compatibility Test
  • 8.2.13 Weather resistance and UV resistance test
  • 8.2.14 Tensile Test
  • 8.2.15 Forward and Reverse Winding Test
  • 8.2.16 Thermal shock test
  • 8.2.17 Insulation and Sheath Shrinkage Test
  • 8.2.18 Thermal stretching test
  • 8.2.19 Cyclic Aging Test of Heating Cables
  • 8.2.20 Cyclic aging test of joints and sealing terminals
  • 8.2.21 Inspection of Marking Durability
  • 8.2.22 High-temperature pressure test of insulation and sheath
  • 8.3 Routine and Sampling Tests
  • 8.3.1 General Instructions
  • 8.3.2 Withstand Voltage Test
  • 8.3.3 Verification of Heating Cable Resistance and Output Power
  • 8.3.4 Insulation thickness
  • 8.3.5 Sheath thickness
  • 8.3.6 Thermal stretching test
  • Appendix A (Normative) Weather Resistance and UV Resistance Tests
  • Reference

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents".

Drafting.

This document supersedes GB/T 20841-2007 "Heating Cables for Heating and Anti-icing of Domestic Facilities with Rated Voltage of 300/500V", and is consistent with...

Compared with GB/T 20841-2007, apart from structural adjustments and editorial changes, the main technical changes are as follows.

---The scope of application has been changed (see Chapter 1, 1.1 of the 2007 edition);

---The basic principles have been removed (see section 1.2 of the 2007 edition);

---Seven new terms and their definitions have been added, including "cold lead" and "connector" (see Chapter 3);

---The classification has been changed from three categories (A, B, and C) to two levels (M1 and M2) (see Chapter 4, 2007 edition, 1.5);

---The signage has been modified, and specific requirements have been made regarding the content of additional signs, in addition to the spacing between signs (see Chapter 5, 1.6 of the 2007 edition);

---The installation instructions have been revised (see Chapter 6, Appendix A of the 2007 edition);

---The description of the heating cable structure has been changed (see Chapter 7, 1.7 of the 2007 edition);

---The product standard for heating cables with a rated voltage of 300/500V has been deleted (see Chapter 2 of the 2007 edition);

---Added general testing requirements (see 8.1);

---The product conductor type has been changed (see 8.2.1, 1.7.3.2 and 1.7.3.3 in the 2007 edition);

---The requirements for insulation resistance testing and the corresponding test voltage have been changed (see 8.2.2, 3.4.5 of the 2007 edition);

---Verification of the rated output of parallel heating cables has been added (see 8.2.3);

---Verification of the starting current of parallel heating cables has been added (see 8.2.4);

---A single-tube burning test has been added (see 8.2.6);

---The mechanical properties of the finished cables, as well as the corresponding test conditions and requirements, have been changed (see 8.2.7, 1.7.7 of the 2007 edition);

---The scope of test objects for cold shock testing has been changed (see 8.2.8, Table 3 of the 2007 edition);

---A low-temperature bending test has been added (see 8.2.9);

---The applicable objects for insulation material aging have been changed (see 8.2.10, Tables 1 and 2 of the 2007 edition);

---The applicable objects for sheath material aging have been changed (see 8.2.11, Table 3 of the 2007 edition);

---The requirements for compatibility testing have been changed (see 8.2.12, Tables 1, 2 and 3 of the 2007 edition);

---An ultraviolet light resistance test has been added (see 8.2.13);

---The scope of application for thermal shock testing has been changed (see 8.2.16, Table 3 of the 2007 edition);

---The scope of applicable test subjects for the heat shrinkage test has been changed (see 8.2.17, Table 1 of the 2007 edition);

---The relevant test conditions for the thermal stretching test of cross-linked insulation and sheath have been changed (see 8.2.18, Tables 1 and 3 of the 2007 edition);

---Added cyclic aging test for the non-metallic outer layer of heating cables embedded in concrete or mortar (see 8.2.19);

---Added cyclic aging tests to heating cable assemblies embedded in concrete or mortar, including joints and sealing terminals.

(See 8.2.20);

---Added high-temperature pressure testing for insulation and sheath (see 8.2.22);

---Added general requirements for routine testing of cable assemblies (see 8.3.1);

---The requirement for withstand voltage testing has been added (see 8.3.2);

---Added requirements for verifying the resistance and output power of the heating cable (see 8.3.3);

---Insulation thickness requirements have been added (see 8.3.4);

---The requirement for sheath thickness has been increased (see 8.3.5);

---Added thermal stretching tests for cross-linked insulation and sheath (see 8.3.6);

---Weather resistance and UV resistance tests have been added (see Appendix A).

This document is equivalent to IEC 60800:2021 "Heating cables for heating and anti-icing of domestic facilities with rated voltage of 300/500V and below".

Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents.

This document was proposed by the China Electrical Equipment Industry Association.

This document is under the jurisdiction of the National Technical Committee on Standardization of Wires and Cables (SAC/TC213).

1 Scope

This document applies to resistance heating cables used in low-temperature environments, such as for heating domestic facilities and preventing icing. Heating cables and heating...

Cable assemblies consist of component units assembled in the factory or on-site according to the manufacturer's instructions.

Bare conductors and protected conductors with a supply voltage of 50V or less are not included in the scope of this document.

Typical applications include, but are not limited to.

---Heating devices installed inside or under the surface;

---Direct and storage heating;

--- Snow melting and frost protection for roofs, gutters, and pipes.

Resistance heating systems, such as mineral-insulated heating cables, are described in detail in the IEC 62395 series of standards for industrial and commercial applications.

The application of explosive atmospheres is detailed in the IEC/IEEE 60079-30 series of standards.

Applications with sheaths operating at temperatures exceeding 100°C are not covered by this document.

The purpose of this document is to ensure the safe operation of heating cables under normal, specified operating conditions. This is achieved through the following methods.

---Use heating cables of appropriate construction that meet the test requirements described in this document;

---Including heating cables with electrical protection components, featuring a metal braided structure, concentric conductors or sheath, or other suitable conductive materials.

Materials for protection in the event of a failure;

---The construction and installation materials for heating cables should comply with national regulations to ensure that the heating cables operate at safe temperatures.

2 Normative references

The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included.

For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies.

This document.

GB/T 16422.3-2022 Plastics - Laboratory Light Source Exposure Tests - Part 3: Fluorescent Ultraviolet Lamps (ISO 4892-3.

2016, IDT)

GB/T 32348.1-2015 Resistance heating systems for industrial and commercial use – Part 1: General and test requirements (IEC 62395-1.

2013, IDT)

Note. GB/T 2900.10-2013 Electrical Terminology - Cables (IEC 60050-461:2008, IDT) Note. GB/T 3956-2008 Conductors of Cables (IEC 60050-461:2008, IDT) IEC 60332-1-1 Cables and optical fibers - Burning tests under flame conditions - Part 11: Single-insulated wires and cables - Vertical flame test Note. GB/T 18380.11-2022 Burning Tests of Cables and Optical Fibers under Flame Conditions - Part 11: Vertical Flame Spread of Single-Strand Insulated Wires and Cables Test apparatus (IEC 60332-1-1:2015, IDT)

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 20841-2025

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
19 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 20841-2025

$410.00